[Paper Review] An IoT Framework for Building Energy Optimization Using Machine Learning-based MPC
This paper proposes an IoT-enabled, machine learning-based Model Predictive Control (MPC) framework for optimizing energy use in legacy building HVAC systems using only temperature sensors and minimal building data. By employing an Artificial Neural Network (ANN) to dynamically estimate thermal model parameters in real time—incorporating weather and occupancy data—the system achieves a 57.59% reduction in electricity consumption compared to manual control, while maintaining user comfort and enabling compatibility with binary (ON/OFF) controllers.
This study proposes a machine learning-based Model Predictive Control (MPC) approach for controlling Air Handling Unit (AHU) systems by employing an Internet of Things (IoT) framework. The proposed framework utilizes an Artificial Neural Network (ANN) to provide dynamic-linear thermal model parameters considering building information and disturbances in real time, thereby facilitating the practical MPC of the AHU system. The proposed framework allows users to establish new setpoints for a closed-loop control system, enabling customization of the thermal environment to meet individual needs with minimal use of the AHU. The experimental results demonstrate the cost benefits of the proposed machine-learning-based MPC-IoT framework, achieving a 57.59\% reduction in electricity consumption compared with a clock-based manual controller while maintaining a high level of user satisfaction. The proposed framework offers remarkable flexibility and effectiveness, even in legacy systems with limited building information, making it a pragmatic and valuable solution for enhancing the energy efficiency and user comfort in pre-existing structures.
Motivation & Objective
- To address the energy inefficiency of legacy buildings with outdated HVAC systems lacking advanced controls.
- To overcome the high cost and complexity of acquiring detailed building envelope data for thermal modeling.
- To enable effective Model Predictive Control (MPC) in buildings with only basic controllers (e.g., ON/OFF or PI/PID) by using data-driven thermal models.
- To demonstrate that real-time, adaptive thermal modeling via machine learning can significantly improve energy efficiency without major infrastructure upgrades.
- To provide a scalable, low-cost solution for retrofitting existing buildings with smart energy optimization using only temperature sensors and wireless data.
Proposed method
- An Artificial Neural Network (ANN) is trained on real-time data from wireless sensor networks (WSNs), including indoor/outdoor temperature, humidity, and weather conditions (e.g., solar radiation, wind speed).
- The ANN dynamically estimates time-varying thermal model parameters (e.g., heat transfer coefficients) to represent the building’s thermal dynamics in real time.
- The estimated parameters are used in a Model Predictive Control (MPC) algorithm to generate optimal setpoints for the Air Handling Unit (AHU) system.
- The MPC controller is adapted to interface with legacy binary or analog controllers (e.g., ON/OFF, PI/PID) through parameter extraction and signal mapping.
- The system uses an hourly data integration strategy to incorporate weather disturbances into the ML model, improving prediction accuracy.
- The framework is deployed in a real building over multiple seasons, with energy consumption and user comfort monitored via sensors and feedback surveys.

Experimental results
Research questions
- RQ1Can a machine learning-based thermal model trained on minimal sensor data effectively replace detailed building envelope information for MPC in legacy HVAC systems?
- RQ2How does the performance of an ML-based MPC controller compare to a conventional manual timer controller in terms of energy consumption and thermal comfort?
- RQ3To what extent can an adaptive, data-driven thermal model improve MPC accuracy in buildings with dynamic thermal behavior?
- RQ4Can the proposed IoT framework be effectively integrated with low-cost, binary-based HVAC controllers without requiring hardware upgrades?
- RQ5What is the real-world energy savings potential of the proposed framework in actual operational conditions across different seasons?
Key findings
- The proposed ML-based MPC-IoT framework achieved a 57.59% reduction in electricity consumption compared to a clock-based manual controller over a 12-week period.
- The system maintained high user satisfaction despite significant energy savings, as confirmed by occupant feedback surveys.
- The ANN-based thermal model effectively captured dynamic thermal behavior, including variations due to weather and occupancy, with only temperature and basic weather data.
- The framework demonstrated robust performance in both heating and cooling seasons, though AHU cooling capacity was found insufficient in summer, leading to high humidity and discomfort.
- Energy consumption was reduced to approximately 4920 kW with the IoT solution versus 11,660 kW with manual control, confirming substantial savings.
- The framework proved effective even in buildings with limited building information, proving its practicality for retrofitting existing structures.

Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.