Skip to main content
QUICK REVIEW

[Paper Review] An Unsupervised Homogenization Pipeline for Clustering Similar Patients using Electronic Health Record Data

Alvaro Ulloa, Anna O. Basile|arXiv (Cornell University)|Dec 30, 2017
Machine Learning in HealthcareComputer Science8 references5 citations
TL;DR

This paper proposes an unsupervised homogenization pipeline for clustering patients using electronic health record (EHR) data, integrating multiple imputation by chained equations (MICE), normalization, and feature reduction techniques. The optimal pipelines—MICE with Local Linear Embedding (LLE) or MICE with Z-scoring and Deep Autoencoders (DAE)—achieved high clustering accuracy on simulated EHR data with redundancy, heterogeneity, and missingness, demonstrating robustness for precision medicine applications.

ABSTRACT

Electronic health records (EHR) contain a large variety of information on the clinical history of patients such as vital signs, demographics, diagnostic codes and imaging data. The enormous potential for discovery in this rich dataset is hampered by its complexity and heterogeneity. We present the first study to assess unsupervised homogenization pipelines designed for EHR clustering. To identify the optimal pipeline, we tested accuracy on simulated data with varying amounts of redundancy, heterogeneity, and missingness. We identified two optimal pipelines: 1) Multiple Imputation by Chained Equations (MICE) combined with Local Linear Embedding; and 2) MICE, Z-scoring, and Deep Autoencoders.

Motivation & Objective

  • To address the challenge of clustering patients in heterogeneous, incomplete, and noisy EHR data.
  • To develop and validate a comprehensive unsupervised homogenization pipeline that integrates imputation, normalization, feature reduction, and clustering.
  • To identify the most robust pipeline configuration for detecting biologically meaningful patient clusters despite data complexity.
  • To evaluate pipeline performance using simulated EHR data with controlled ground truth for accuracy assessment.
  • To provide a validated, end-to-end framework for unsupervised phenotyping applicable to real-world EHR datasets.

Proposed method

  • Simulated EHR data was generated with three clusters, redundancy via projection, heterogeneity via quantization and scaling, and noise via Gaussian perturbation.
  • Imputation techniques tested included median imputation, k-Nearest Neighbors (KNN), and Multiple Imputation by Chained Equations (MICE), with MICE selected as optimal.
  • Normalization methods evaluated were Z-score, MinMax, and Whitening, with Z-score used in the optimal DAE pipeline.
  • Feature reduction was performed using Local Linear Embedding (LLE) and Deep Autoencoders (DAE), with hyperparameters tuned via reconstruction error.
  • Clustering performance was evaluated using adjusted Rand index (ARI) on simulated data with varying levels of redundancy, missingness, and noise.
  • The pipeline was validated across multiple experimental conditions, including interaction effects between noise and missingness, to assess robustness.

Experimental results

Research questions

  • RQ1Which imputation method yields the most accurate clustering results in the presence of missing EHR data?
  • RQ2How do different normalization and feature reduction techniques impact clustering performance on heterogeneous and redundant EHR data?
  • RQ3What is the relative performance of LLE versus DAE in preserving cluster structure under varying levels of noise and missingness?
  • RQ4Can a unified pipeline combining MICE, normalization, and feature reduction consistently outperform individual components in simulated EHR clustering?
  • RQ5How do interactions between data quality factors (e.g., noise and missingness) affect the robustness of the proposed pipeline?

Key findings

  • MICE outperformed median imputation and KNN across all feature reduction methods, particularly under high missingness and redundancy.
  • The pipeline combining MICE with Local Linear Embedding (LLE) achieved the highest clustering accuracy, outperforming DAE by 0.05–0.12 ARI at medium effect size and high uninformative noise.
  • The MICE–Z-score–DAE pipeline showed strong performance and offered superior computational efficiency, scaling as O(m log(k)n log(n)) compared to LLE’s O(nm).
  • LLE demonstrated better sensitivity to granular phenotypes with 1–5% sample overlap, suggesting improved detection of subtle disease subtypes.
  • The interaction experiments revealed that DAE and LLE showed significant performance differences in specific noise and missingness regimes, with DAE more stable under high missingness.
  • The study identified two optimal pipelines: MICE + LLE and MICE + Z-score + DAE, both robust across diverse data quality conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.