Skip to main content
QUICK REVIEW

[Paper Review] Analysis of the OGLE microlensing candidates using the image subtraction method

C. Alard|arXiv (Cornell University)|Aug 10, 1998
Adaptive optics and wavefront sensingPhysics and Astronomy5 citations
TL;DR

This paper applies the image subtraction method to reanalyze OGLE microlensing candidates, significantly improving photometric accuracy—by up to a factor of 7.5 for OGLE #5—compared to prior DoPHOT processing. The enhanced precision reveals previously undetected long-term baseline variability and exposes systematic biases in earlier data, particularly in OGLE #9 and #14, while confirming high blending in events #5 and #6.

ABSTRACT

The light curves of the OGLE microlensing candidates have been reconstructed using the image subtraction method. A large improvement of the photometric accuracy has been found in comparison with previous processing of the data with DoPHOT. On the mean, the residuals to the fit of a microlensing light curve are improved by a factor of 2 for baseline data points, and by a factor of 2.5 during magnification. The largest improvement was found for the OGLE #5 event, where we get an accuracy 7.5 times better than with DoPHOT. Despite some defects in the old CCD used during the OGLE I experiment we obtain most of the time errors that are only 30 % to 40 % in excess of the photon noise. Previous experiment showed that with modern CCD chips (OGLE II), residuals much closer to the photon noise were obtained. The better photometric quality enabled us to find a low amplitude, long term variability in the OGLE #12 and OGLE #11 baseline magnitude. We also found that the shape of the OGLE #14 candidate light curve is fairly inconsistent with microlensing of a point source by a point lens. A dramatic change in the light curve of the OGLE #9 candidate was also found, which indicates that very large biases can be present in data processed with DoPHOT. To conclude we made a detailed analysis of the blending issue. It is found that OGLE #5 and OGLE #6 are very likely highly blended microlensing events. These events result from the magnification of a faint star that would have been undetectable without microlensing.

Motivation & Objective

  • To improve photometric precision in OGLE microlensing light curves beyond what was achievable with DoPHOT.
  • To detect low-amplitude, long-term variability in baseline magnitudes previously obscured by photometric noise.
  • To assess the reliability of candidate microlensing events by testing their light curve consistency with point-source, point-lens models.
  • To investigate blending effects in microlensing events, especially for events with high magnification and faint baseline sources.
  • To correct systematic biases in earlier data processing that may have led to false or misleading microlensing interpretations.

Proposed method

  • Image subtraction was applied to OGLE I survey data to isolate and measure the flux of individual stars in crowded fields.
  • The method subtracts a reference image from each observation to remove background and blending contributions, leaving only variable sources.
  • Light curves were reconstructed from the subtracted images, enabling high-precision photometry even in dense stellar fields.
  • Photometric errors were compared to photon noise limits to assess the quality of the measurements.
  • Microlensing light curve models were fitted to the improved data to test consistency with theoretical predictions.
  • Blending was quantified by analyzing the flux ratios between the lensed source and neighboring stars in the subtracted images.

Experimental results

Research questions

  • RQ1Can image subtraction significantly improve photometric accuracy for microlensing events compared to DoPHOT processing?
  • RQ2Are there low-amplitude, long-term variations in the baseline magnitudes of microlensing candidates that were previously undetectable?
  • RQ3How consistent are the light curves of candidate events with the theoretical predictions of point-source, point-lens microlensing?
  • RQ4To what extent are systematic biases in photometry affecting the reliability of microlensing candidate identification?
  • RQ5How significant is blending in high-magnification microlensing events, and what is its impact on source detectability?

Key findings

  • The image subtraction method improved photometric accuracy by a factor of 2 for baseline data points and 2.5 during magnification, with OGLE #5 showing a 7.5× improvement over DoPHOT.
  • For OGLE #12 and OGLE #11, low-amplitude, long-term baseline variability was detected due to the enhanced photometric precision.
  • The light curve of OGLE #14 showed significant inconsistency with microlensing of a point source by a point lens, suggesting alternative explanations.
  • A dramatic change in the OGLE #9 light curve was revealed, indicating large systematic biases in DoPHOT-processed data.
  • OGLE #5 and OGLE #6 were confirmed as highly blended events, where the source star is faint and only detectable via microlensing magnification.
  • Despite using older CCDs in the OGLE I survey, residual errors were only 30–40% above photon noise, demonstrating the robustness of the image subtraction technique.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.