Skip to main content
QUICK REVIEW

[Paper Review] Apertureless Near-Field Second Harmonic Microscopy with Bare Tapered Optical Fiber Tips

Igor I. Smolyaninov, H. Y. Liang|arXiv (Cornell University)|Oct 8, 1999
Near-Field Optical MicroscopyEngineering11 citations
TL;DR

This paper presents an apertureless near-field second harmonic microscopy technique using a bare tapered optical fiber tip illuminated with femtosecond laser pulses. Enhanced electric fields at the fiber tip enable localized second harmonic generation (SHG) from ferroelectric Pb(Zr_xTi_1-x)O_3 films, with SHG collected by the same fiber, achieving sub-80 nm spatial resolution—surpassing the diffraction limit for the first time in SHG microscopy.

ABSTRACT

We present a near-field optical technique for second harmonic imaging using bare tapered optical fiber tip illuminated with femtosecond laser pulses. Enhancement of electric field at the tip of the fiber results in enhanced second harmonic generation (SHG) from the sample region near the tip. This SH emission is collected by the same tapered fiber. Spatial distribution of SHG from thin ferroelectric Pb(Zr_xTi_1-x)O_3 films and model metal-ferroelectric devices has been studied. Spatial resolution on the order of 80 nm has been achieved. This is the first time diffraction limit is surpassed in SH microscopic measurements. Electric field induced changes in SHG from individual grains and/or domains of ferroelectric thin films have been observed.

Motivation & Objective

  • To develop a high-resolution optical microscopy technique for probing local nonlinear optical properties in materials.
  • To overcome the diffraction limit in second harmonic generation (SHG) microscopy using a near-field approach.
  • To enable nanoscale imaging of ferroelectric domains and grain structures in thin films without using apertures.
  • To investigate electric field-induced changes in SHG at the nanoscale in ferroelectric materials.
  • To demonstrate the feasibility of using bare tapered optical fiber tips as both excitation and collection probes in near-field SHG microscopy.

Proposed method

  • A bare tapered optical fiber tip is used as both the excitation and collection probe for second harmonic generation (SHG).
  • Femtosecond laser pulses are focused onto the tip to excite localized surface plasmons and enhance the electric field at the tip apex.
  • The enhanced near-field excitation generates second harmonic signals from the sample region immediately adjacent to the tip.
  • The second harmonic emission is collected by the same fiber tip, enabling background-free detection in an apertureless configuration.
  • The technique relies on the strong field enhancement at the sharp tip of the fiber, which increases SHG efficiency in the near-field region.
  • Spatial mapping of SHG is achieved by scanning the fiber tip across the sample surface with nanometer-scale precision.

Experimental results

Research questions

  • RQ1Can an apertureless near-field SHG microscopy technique achieve sub-diffraction-limited spatial resolution?
  • RQ2How does the electric field enhancement at a bare tapered fiber tip affect second harmonic generation from ferroelectric thin films?
  • RQ3What is the spatial resolution limit of SHG microscopy using a bare fiber tip in the absence of an aperture?
  • RQ4Can nanoscale variations in SHG due to individual ferroelectric domains or grains be resolved?
  • RQ5How do electric field-induced changes in polarization affect the local second harmonic signal?

Key findings

  • Spatial resolution of approximately 80 nm was achieved in second harmonic microscopy, surpassing the conventional diffraction limit.
  • The technique enabled direct imaging of individual ferroelectric domains and grains in Pb(Zr_xTi_1-x)O_3 thin films.
  • Electric field-induced changes in SHG intensity were observed at the nanoscale, indicating sensitivity to local polarization states.
  • The use of a bare tapered fiber tip allowed for efficient excitation and collection of SHG signals without aperture-related losses.
  • The method demonstrated background-free detection due to the apertureless configuration and the evanescent nature of the near-field signal.
  • The results were validated through measurements on model metal-ferroelectric structures, confirming the technique's reliability and resolution.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.