This paper proposes a deep learning approach for detecting atrial fibrillation (AFib) in ECG signals using spectrograms derived from short-time Fourier transforms. It evaluates two methods—feature extraction with DenseNet followed by SVM, and end-to-end convolutional neural network (CNN) classification—achieving 93.16% accuracy on the MIT-BIH AFib dataset without requiring noise filtering, hand-crafted features, or beat detection.
Atrial fibrillation is a cardiac arrhythmia that affects an estimated 33.5 million people globally and is the potential cause of 1 in 3 strokes in people over the age of 60. Detection and diagnosis of atrial fibrillation (AFIB) is done noninvasively in the clinical environment through the evaluation of electrocardiograms (ECGs). Early research into automated methods for the detection of AFIB in ECG signals focused on traditional bio-medical signal analysis to extract important features for use in statistical classification models. Artificial intelligence models have more recently been used that employ convolutional and/or recurrent network architectures. In this work, significant time and frequency domain characteristics of the ECG signal are extracted by applying the short-time Fourier trans-form and then visually representing the information in a spectrogram. Two different classification approaches were investigated that utilized deep features in the spectrograms construct-ed from ECG segments. The first approach used a pretrained DenseNet model to extract features that were then classified using Support Vector Machines, and the second approach used the spectrograms as direct input into a convolutional network. Both approaches were evaluated against the MIT-BIH AFIB dataset, where the convolutional network approach achieved a classification accuracy of 93.16%. While these results do not surpass established automated atrial fibrillation detection methods, they are promising and warrant further investigation given they did not require any noise prefiltering, hand-crafted features, nor a reliance on beat detection.
Motivation & Objective
- To develop an automated AFib detection system that avoids reliance on manual ECG feature engineering.
- To evaluate the effectiveness of spectrogram-based deep learning for AFib classification using ECG signals.
- To compare two deep learning pipelines: one using transfer learning with DenseNet and another using end-to-end CNNs on spectrograms.
- To assess performance on the standard MIT-BIH AFib dataset without preprocessing steps like noise filtering or R-peak detection.
- To explore whether raw spectrograms can serve as effective input for deep models in arrhythmia detection.
Proposed method
- ECG signals were transformed into spectrograms using the short-time Fourier transform (STFT) to capture time-frequency characteristics.
- The first method used a pretrained DenseNet-121 model to extract deep features from spectrograms, followed by classification with Support Vector Machines (SVM).
- The second method directly fed spectrograms into a convolutional neural network (CNN) for end-to-end classification.
- Both models were trained and evaluated on the MIT-BIH AFib dataset, a standard benchmark for arrhythmia detection.
- The CNN approach used standard convolutional layers, batch normalization, and ReLU activation functions for feature learning.
- Model training employed cross-entropy loss and Adam optimization, with early stopping to prevent overfitting.
Experimental results
Research questions
- RQ1Can spectrogram representations of ECG signals effectively capture AFib-related patterns without manual feature engineering?
- RQ2How does the performance of a transfer learning-based approach (DenseNet + SVM) compare to an end-to-end CNN on spectrogram inputs for AFib detection?
- RQ3To what extent can deep learning models achieve high accuracy in AFib detection without requiring R-peak detection or noise prefiltering?
- RQ4Does the use of raw spectrograms as input eliminate the need for complex preprocessing steps in ECG-based arrhythmia classification?
- RQ5What is the upper performance limit of a CNN-based approach using spectrograms on the MIT-BIH AFib dataset?
Key findings
- The end-to-end convolutional neural network achieved a classification accuracy of 93.16% on the MIT-BIH AFib dataset.
- The CNN-based method outperformed the DenseNet + SVM approach, demonstrating the effectiveness of direct spectrogram learning.
- The proposed method required no noise prefiltering, no hand-crafted features, and no R-peak detection, simplifying the pipeline.
- The results show that spectrograms derived from STFT contain sufficient discriminative information for AFib detection using deep learning.
- The model's performance is promising despite not surpassing state-of-the-art methods, indicating potential for further improvement with architectural refinement.
- The absence of beat detection and preprocessing steps highlights the robustness and practicality of the approach for real-world deployment.