Skip to main content
QUICK REVIEW

[Paper Review] Automated HER2 scoring with uncertainty quantification using lensfree holography and deep learning

Che-Yung Shen, Xilin Yang|arXiv (Cornell University)|Jan 26, 2026
Digital Holography and MicroscopyPhysics and Astronomy0 citations
TL;DR

The paper presents a compact lensfree holography platform with deep learning and Bayesian uncertainty quantification to automate HER2 scoring in breast tissue, achieving high accuracy and robust predictions in resource-limited settings.

ABSTRACT

Accurate assessment of human epidermal growth factor receptor 2 (HER2) expression is critical for breast cancer diagnosis, prognosis, and therapy selection; yet, most existing digital HER2 scoring methods rely on bulky and expensive optical systems. Here, we present a compact and cost-effective lensfree holography platform integrated with deep learning for automated HER2 scoring of immunohistochemically stained breast tissue sections. The system captures lensfree diffraction patterns of stained HER2 tissue sections under RGB laser illumination and acquires complex field information over a sample area of ~1,250 mm^2 at an effective throughput of ~84 mm^2 per minute. To enhance diagnostic reliability, we incorporated an uncertainty quantification strategy based on Bayesian Monte Carlo dropout, which provides autonomous uncertainty estimates for each prediction and supports reliable, robust HER2 scoring, with an overall correction rate of 30.4%. Using a blinded test set of 412 unique tissue samples, our approach achieved a testing accuracy of 84.9% for 4-class (0, 1+, 2+, 3+) HER2 classification and 94.8% for binary (0/1+ vs. 2+/3+) HER2 scoring with uncertainty quantification. Overall, this lensfree holography approach provides a practical pathway toward portable, high-throughput, and cost-effective HER2 scoring, particularly suited for resource-limited settings, where traditional digital pathology infrastructure is unavailable.

Motivation & Objective

  • Develop a compact, cost-effective lensfree holography system to capture HER2 tissue diffraction patterns for automated scoring.
  • Integrate deep learning to perform 4-class and binary HER2 classification from captured data.
  • Incorporate Bayesian Monte Carlo dropout to provide per-prediction uncertainty estimates.
  • Evaluate system performance on a blinded test set and compare to reference HER2 scoring metrics.

Proposed method

  • Capture lensfree diffraction patterns of immunohistochemically stained breast tissue under RGB laser illumination over ~1,250 mm^2 at ~84 mm^2/min throughput.
  • Apply deep learning models to predict HER2 scores (0, 1+, 2+, 3+) and a binary (0/1+ vs 2+/3+) classification.
  • Introduce uncertainty quantification via Bayesian Monte Carlo dropout to obtain autonomous prediction confidence for each sample.
  • Report correction rate and overall performance on a blinded dataset to assess reliability in clinical-like workflows.

Experimental results

Research questions

  • RQ1Can a lensfree holography platform achieve clinically relevant HER2 scoring performance comparable to standard digital pathology?
  • RQ2Does Bayesian Monte Carlo dropout provide meaningful uncertainty estimates to support robust HER2 predictions?
  • RQ3What are the accuracy gains and reliability trade-offs of 4-class vs. binary HER2 scoring in this lensfree framework?
  • RQ4Is the approach scalable and throughput-adequate for resource-limited settings?
  • RQ5How does the proposed system perform on blinded data in terms of accuracy and correction rate?

Key findings

  • Achieved 84.9% testing accuracy for 4-class (0, 1+, 2+, 3+) HER2 classification on a blinded test set of 412 samples.
  • Achieved 94.8% accuracy for binary (0/1+ vs. 2+/3+) HER2 scoring with uncertainty quantification.
  • Demonstrated throughput of ~84 mm^2 per minute over an acquisition area of ~1,250 mm^2 while using RGB laser illumination.
  • Integrated Bayesian Monte Carlo dropout to provide autonomous uncertainty estimates for each prediction, supporting robust scoring.
  • Reported an overall correction rate of 30.4% in the context of uncertainty-informed predictions.
  • Argues for portability, high-throughput capability, and cost-effectiveness in resource-limited settings where traditional digital pathology is scarce.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.