Skip to main content
QUICK REVIEW

[Paper Review] Automated Muscle Segmentation from Clinical CT using Bayesian U-Net for Personalized Musculoskeletal Modeling

Yuta Hiasa, Yoshito Otake|arXiv (Cornell University)|Jul 21, 2019
Radiomics and Machine Learning in Medical ImagingMedicine39 references5 citations
TL;DR

This paper proposes a Bayesian U-Net with Monte Carlo dropout for automated, accurate segmentation of individual muscles from clinical CT scans, achieving a Dice coefficient of 0.891 ± 0.016 and demonstrating that uncertainty estimates enable effective active learning, reducing manual annotation costs in musculoskeletal modeling applications.

ABSTRACT

We propose a method for automatic segmentation of individual muscles from a clinical CT. The method uses Bayesian convolutional neural networks with the U-Net architecture, using Monte Carlo dropout that infers an uncertainty metric in addition to the segmentation label. We evaluated the performance of the proposed method using two data sets: 20 fully annotated CTs of the hip and thigh regions and 18 partially annotated CTs that are publicly available from The Cancer Imaging Archive (TCIA) database. The experiments showed a Dice coefficient (DC) of 0.891 +/- 0.016 (mean +/- std) and an average symmetric surface distance (ASD) of 0.994 +/- 0.230 mm over 19 muscles in the set of 20 CTs. These results were statistically significant improvements compared to the state-of-the-art hierarchical multi-atlas method which resulted in 0.845 +/- 0.031 DC and 1.556 +/- 0.444 mm ASD. We evaluated validity of the uncertainty metric in the multi-class organ segmentation problem and demonstrated a correlation between the pixels with high uncertainty and the segmentation failure. One application of the uncertainty metric in active-learning is demonstrated, and the proposed query pixel selection method considerably reduced the manual annotation cost for expanding the training data set. The proposed method allows an accurate patient-specific analysis of individual muscle shapes in a clinical routine. This would open up various applications including personalization of biomechanical simulation and quantitative evaluation of muscle atrophy.

Motivation & Objective

  • To develop an automated method for segmenting individual muscles from clinical CT scans to enable patient-specific musculoskeletal modeling.
  • To address the challenge of low soft-tissue contrast and complex muscle anatomy in CT, particularly in the hip and thigh regions.
  • To integrate uncertainty estimation into deep learning segmentation to guide active learning and reduce manual annotation burden.
  • To improve upon existing state-of-the-art methods, such as hierarchical multi-atlas segmentation, in accuracy and computational efficiency.
  • To support clinical applications such as biomechanical simulation and quantitative assessment of muscle atrophy or fatty degeneration.

Proposed method

  • The method employs a two-stage pipeline: first, a deterministic U-Net segments the skin surface, followed by a Bayesian U-Net for individual muscle segmentation.
  • Bayesian U-Net uses Monte Carlo dropout at inference time to estimate predictive uncertainty across multiple forward passes.
  • Uncertainty maps are generated per pixel, with high uncertainty indicating potential segmentation errors or ambiguous boundaries.
  • An active learning framework selects slices with high uncertainty for expert annotation, while low-uncertainty slices are used to expand the training set.
  • A similarity-based clustering algorithm selects representative slices from uncertain regions to prioritize annotation in active learning.
  • The model is trained and evaluated on two datasets: 20 fully annotated hip/thigh CT scans and 18 partially annotated TCIA scans.

Experimental results

Research questions

  • RQ1Can a Bayesian U-Net with Monte Carlo dropout achieve higher segmentation accuracy than state-of-the-art methods for individual muscle segmentation in clinical CT?
  • RQ2Can the uncertainty map generated by the Bayesian U-Net effectively identify regions prone to segmentation failure?
  • RQ3To what extent can uncertainty-driven active learning reduce the number of required manual annotations for training?
  • RQ4How does the proposed method compare to hierarchical multi-atlas segmentation in terms of Dice coefficient and surface distance metrics?
  • RQ5Can the uncertainty metric guide effective data selection in active learning for clinical CT segmentation?

Key findings

  • The proposed method achieved a Dice coefficient of 0.891 ± 0.016 and an average symmetric surface distance of 0.994 ± 0.230 mm on 19 muscles in 20 fully annotated CT scans.
  • The method significantly outperformed the hierarchical multi-atlas method, which achieved 0.845 ± 0.031 Dice and 1.556 ± 0.444 mm surface distance.
  • A strong correlation was observed between pixels with high uncertainty and actual segmentation errors, validating the uncertainty map as a reliable failure indicator.
  • The uncertainty-driven active learning strategy reduced manual annotation cost by prioritizing the most informative slices, as demonstrated in simulation.
  • The method achieved high accuracy with minimal computational overhead, making it suitable for clinical deployment compared to computationally heavy multi-atlas methods.
  • The uncertainty metric enabled effective data selection, with the learning curve showing rapid initial improvement, suggesting high data efficiency.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.