TL;DR

This paper proposes a deep learning-based, parameter-free method for automatic intensity normalization of breast DCE-MRI scans across diverse scanners and protocols. Using tissue segmentation to identify air, fat, dense tissue, and heart as intensity anchors, it applies subject-specific piecewise linear mapping to align tissue intensities across patients, significantly improving consistency in pixel values and radiomics features without requiring scanner parameters.

ABSTRACT

Objective: To develop an automatic image normalization algorithm for intensity correction of images from breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) acquired by different MRI scanners with various imaging parameters, using only image information. Methods: DCE-MR images of 460 subjects with breast cancer acquired by different scanners were used in this study. Each subject had one T1-weighted pre-contrast image and three T1-weighted post-contrast images available. Our normalization algorithm operated under the assumption that the same type of tissue in different patients should be represented by the same voxel value. We used four tissue/material types as the anchors for the normalization: 1) air, 2) fat tissue, 3) dense tissue, and 4) heart. The algorithm proceeded in the following two steps: First, a state-of-the-art deep learning-based algorithm was applied to perform tissue segmentation accurately and efficiently. Then, based on the segmentation results, a subject-specific piecewise linear mapping function was applied between the anchor points to normalize the same type of tissue in different patients into the same intensity ranges. We evaluated the algorithm with 300 subjects used for training and the rest used for testing. Results: The application of our algorithm to images with different scanning parameters resulted in highly improved consistency in pixel values and extracted radiomics features. Conclusion: The proposed image normalization strategy based on tissue segmentation can perform intensity correction fully automatically, without the knowledge of the scanner parameters. Significance: We have thoroughly tested our algorithm and showed that it successfully normalizes the intensity of DCE-MR images. We made our software publicly available for others to apply in their analyses.

Motivation & Objective

  • To address intensity inconsistency in DCE-MRI scans acquired with varying MRI scanners and protocols, which hinders quantitative radiomics and radiogenomics analysis.
  • To develop a fully automatic normalization method that does not rely on physical scanner parameters or acquisition metadata.
  • To ensure consistent tissue intensity ranges across patients by leveraging deep learning for tissue segmentation and piecewise linear mapping.
  • To improve the discriminative power of radiomics features for clinical tasks such as molecular subtype classification.
  • To provide a publicly available, computationally efficient tool for researchers to standardize DCE-MRI data.

Proposed method

  • A U-Net-based fully convolutional network (FCN) is trained to segment three tissue types—fat, dense tissue, and heart—on pre-contrast DCE-MRI scans.
  • The algorithm uses four tissue/material types (air, fat, dense tissue, heart) as intensity anchors to define target intensity ranges.
  • Subject-specific piecewise linear mapping functions are computed based on median intensity values of each tissue type in the input image and the corresponding target range.
  • The mapping is applied independently per tissue type to ensure consistent intensity representation across patients.
  • The method operates without knowledge of scanner field strength, TR, TE, or contrast agent type, relying solely on image content.
  • The normalization pipeline is computationally efficient, with total processing time under 25 seconds per 3D volume.

Experimental results

Research questions

  • RQ1Can a deep learning-based segmentation approach enable automatic intensity normalization of DCE-MRI without requiring scanner parameter information?
  • RQ2Does piecewise linear mapping based on tissue-specific intensity anchors reduce inter-scanner intensity variability in breast DCE-MRI?
  • RQ3To what extent does the proposed normalization improve the discriminative power of radiomics features for molecular subtyping?
  • RQ4How robust is the method across diverse MRI scanners, field strengths, and acquisition protocols?
  • RQ5Can the method tolerate imperfect segmentation masks while still achieving effective intensity normalization?

Key findings

  • The proposed method significantly improved the consistency of pixel intensity distributions across DCE-MRI scans acquired with different scanners and protocols.
  • After normalization, the mean intensity of the same tissue type (e.g., fat or dense tissue) across patients was aligned within a narrow, consistent range.
  • Radiomics features extracted from normalized images showed higher discriminative power in classifying breast cancer molecular subtypes compared to features from original, unnormalized images.
  • The algorithm achieved a mean computational time of 24.4 seconds per 3D DCE-MRI volume (512×512×90), with segmentation of dense tissue being the most time-consuming step (13.6 s).
  • The method was robust to imperfect training masks, with predicted segmentation masks outperforming the coarse, unsupervised-generated training masks in quality.
  • The normalization effectively reduced intensity disparities for most radiomics features, although it did not mitigate noise-related differences (e.g., standard deviation of SER for feature F6 remained high).

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.