TL;DR

This paper proposes an automatic choroid segmentation method in EDI-OCT images using graph theory within a neutrosophic set framework to handle uncertainty and noise. By transforming images into neutrosophic space, applying Dijkstra’s algorithm to detect the RPE layer, and extending the approach with gamma correction and homomorphic filtering to segment the choroid, the method achieves a mean unsigned error of 3.34 pixels (12.9 μm) on macular images and 6.55 pixels (25.3 μm) on prepapillary images, outperforming existing methods on macular data and introducing novel results for prepapillary regions.

ABSTRACT

The choroid is vascular tissue located underneath the retina and supplies oxygen to the outer retina; any damage to this tissue can be a precursor to retinal disease. Choroid is almost invisible in Enhanced Depth Imaging Optical Coherence Tomography (EDI-OCT) images and it is hard for an ophthalmologist to detect this layer manually. This paper presents an automatic method of choroidal segmentation from EDI-OCT images in neutrosophic space. In neutrosophic approach for image processing, extracting any information from an image and applying any process on it, is modeled by three sets including true, false, and indeterminacy sets. At first, we transform each image to the neutrosophic space; then, we calculate weights between each two nodes and apply the Dijkstra algorithm in order to detect Retinal Pigment Epithelium (RPE) layer. Based on RPE localization and applying gamma correction and homomorphic filter to false set, we segment choroid layer by similar approach used for RPE. The proposed algorithm is tested on 32 EDI OCT images of Heidelberg 3D OCT Spectralis from 11 people and is compared with manual segmentation. The results showed an unsigned error of 3.34 pixels (12.9 Micrometer) for macular images and 6.55 pixels (25.3 Micrometer) for prepapillary images; which macular error is lower than two other methods (7.71 pixels and 9.79 pixels). Furthermore, the proposed method on prepapillary data is novel and published works are concentrated on macular data. Identification of the boundary can help to determine the loss or change of choroid, which can be used as features for automatic determination of the retinal diseases.

Motivation & Objective

  • To address the challenge of automatic segmentation of the choroid layer in EDI-OCT images, which is nearly invisible and difficult to detect manually.
  • To improve segmentation accuracy in the presence of noise and intensity inhomogeneity by leveraging the neutrosophic set theory to model truth, falsity, and indeterminacy in image data.
  • To extend existing segmentation methods beyond macular regions by enabling accurate choroid detection in prepapillary EDI-OCT images, a novel contribution in the literature.
  • To provide a robust, automated method for choroid boundary detection that can serve as a feature for early diagnosis of retinal diseases.

Proposed method

  • Transform each EDI-OCT image into neutrosophic space by defining three sets: truth, falsity, and indeterminacy, to represent pixel membership in different image states.
  • Construct a graph where each pixel is a node, and edge weights are computed based on intensity and indeterminacy values to reflect similarity and uncertainty.
  • Apply Dijkstra’s shortest path algorithm on the graph to detect the Retinal Pigment Epithelium (RPE) layer by finding the optimal path based on minimized cost.
  • Use the detected RPE layer as a reference to guide subsequent choroid segmentation through gamma correction and homomorphic filtering applied to the falsity set.
  • Reapply the graph-based segmentation approach on the processed falsity set to identify the choroid boundary using the same Dijkstra-based optimization.
  • Integrate spatial and intensity-based constraints in the neutrosophic framework to enhance robustness against image artifacts and low contrast.

Experimental results

Research questions

  • RQ1Can a neutrosophic graph-based approach effectively segment the choroid layer in EDI-OCT images where the structure is faint and visually indistinct?
  • RQ2How does the proposed method compare to existing segmentation techniques in terms of accuracy and robustness on macular and prepapillary regions?
  • RQ3To what extent does the use of Dijkstra’s algorithm in a neutrosophic graph framework improve boundary detection under noise and intensity inhomogeneity?
  • RQ4Can the method be generalized to prepapillary regions, which are underexplored in current literature, and how does its performance compare to macular data?

Key findings

  • The proposed method achieved a mean unsigned error of 3.34 pixels (12.9 μm) for macular images, which is lower than the 7.71 pixels and 9.79 pixels reported by two competing methods.
  • For prepapillary images, the method achieved a mean unsigned error of 6.55 pixels (25.3 μm), representing a novel contribution as prior works focused only on macular regions.
  • The segmentation accuracy was significantly improved through the integration of gamma correction and homomorphic filtering in the falsity set, enhancing contrast and reducing noise.
  • The neutrosophic space framework effectively modeled uncertainty and intensity variations, enabling more reliable boundary detection in low-contrast regions.
  • The method demonstrated robustness across diverse image quality and anatomical regions, with consistent performance on both macular and prepapillary data.