Skip to main content
QUICK REVIEW

[Paper Review] Automatic Segmentation of Organs-at-Risk from Head-and-Neck CT using Separable Convolutional Neural Network with Hard-Region-Weighted Loss

Wenhui Lei, Haochen Mei|arXiv (Cornell University)|Feb 3, 2021
Head and Neck Cancer StudiesMedicine49 references4 citations
TL;DR

This paper proposes a 3D-SepNet framework with separable convolutions and a hard-region-weighted loss for accurate, uncertainty-aware segmentation of organs-at-risk (OARs) in head-and-neck CT scans. By integrating a Segmental Linear Function (SLF) for multi-organ visibility and ensemble learning for uncertainty estimation, the method achieves a weighted average Dice score of 80.52% and 95% Hausdorff distance of 3.043 mm, outperforming 3D UNet with 1/3 the parameters.

ABSTRACT

Nasopharyngeal Carcinoma (NPC) is a leading form of Head-and-Neck (HAN) cancer in the Arctic, China, Southeast Asia, and the Middle East/North Africa. Accurate segmentation of Organs-at-Risk (OAR) from Computed Tomography (CT) images with uncertainty information is critical for effective planning of radiation therapy for NPC treatment. Despite the stateof-the-art performance achieved by Convolutional Neural Networks (CNNs) for automatic segmentation of OARs, existing methods do not provide uncertainty estimation of the segmentation results for treatment planning, and their accuracy is still limited by several factors, including the low contrast of soft tissues in CT, highly imbalanced sizes of OARs and large inter-slice spacing. To address these problems, we propose a novel framework for accurate OAR segmentation with reliable uncertainty estimation. First, we propose a Segmental Linear Function (SLF) to transform the intensity of CT images to make multiple organs more distinguishable than existing methods based on a simple window width/level that often gives a better visibility of one organ while hiding the others. Second, to deal with the large inter-slice spacing, we introduce a novel 2.5D network (named as 3D-SepNet) specially designed for dealing with clinic HAN CT scans with anisotropic spacing. Thirdly, existing hardness-aware loss function often deal with class-level hardness, but our proposed attention to hard voxels (ATH) uses a voxel-level hardness strategy, which is more suitable to dealing with some hard regions despite that its corresponding class may be easy. Our code is now available at https://github.com/HiLab-git/SepNet.

Motivation & Objective

  • To address the challenge of low-contrast soft tissues and highly imbalanced OAR sizes in head-and-neck CT for radiotherapy planning.
  • To improve segmentation accuracy for small, flat, and boundary-ambiguous OARs such as the lens and optical nerves.
  • To provide reliable uncertainty estimation for clinical decision support in radiation therapy.
  • To reduce model complexity while maintaining or improving performance on anisotropic CT scans with high inter-slice spacing.
  • To develop a framework that integrates intensity transformation, attention to hard voxels, and ensemble-based uncertainty quantification.

Proposed method

  • Introduces a Segmental Linear Function (SLF) to enhance visibility of multiple OARs simultaneously by applying non-uniform intensity transforms across different tissue types.
  • Proposes a 3D-SepNet architecture using spatially separable 3D convolutions to efficiently handle anisotropic CT scans with high in-plane resolution and low through-plane resolution.
  • Designs a hardness-aware loss function (ATH-LExp) that combines exponential loss with attention to hard-to-segment voxels, improving performance on challenging regions.
  • Employs ensemble learning by combining models trained with different SLF intensity transforms and loss functions to generate robust segmentation outputs and inherent uncertainty estimates.
  • Uses the variance across ensemble predictions as a proxy for uncertainty, which correlates strongly with mis-segmented regions.
  • Applies a weighted average ensemble strategy to improve generalization and reduce overfitting on imbalanced OAR datasets.
Figure 1: An example of HAN CT images in three orthogonal views. The OARs have imbalanced sizes with a low contrast with the surrounding tissues. Note the large inter-slice spacing highlighted by red arrows and small organs occupying only few slices (e.g.), the optical nerves and the lens highlighte
Figure 1: An example of HAN CT images in three orthogonal views. The OARs have imbalanced sizes with a low contrast with the surrounding tissues. Note the large inter-slice spacing highlighted by red arrows and small organs occupying only few slices (e.g.), the optical nerves and the lens highlighte

Experimental results

Research questions

  • RQ1Can a learnable intensity transformation like SLF improve multi-organ visibility and segmentation accuracy in head-and-neck CT compared to standard window-level adjustments?
  • RQ2How does a separable 3D convolutional network (3D-SepNet) perform relative to standard 3D UNet in segmenting OARs from anisotropic CT scans with high inter-slice spacing?
  • RQ3Does a hardness-aware loss function that emphasizes hard voxels improve segmentation accuracy, especially for small or low-contrast OARs?
  • RQ4Can ensemble-based model outputs provide reliable uncertainty estimates that correlate with segmentation errors in clinical settings?
  • RQ5To what extent can uncertainty maps guide radiologists to focus on high-risk regions for manual refinement in radiotherapy planning?

Key findings

  • The proposed 3D-SepNet achieved a weighted average Dice score of 80.52% and 95% Hausdorff distance of 3.043 mm on the StructSeg 2019 HAN OAR challenge, securing third place.
  • With only 1/3 the number of parameters of 3D UNet, 3D-SepNet outperformed it in segmentation accuracy for most OARs, especially flat or thin structures like the optical nerves and lens.
  • The SLF-based intensity transformation significantly improved segmentation accuracy by enhancing visibility of multiple OARs simultaneously, outperforming standard linear windowing.
  • The ATH-LExp loss function, which emphasizes hard voxels, led to better Dice scores than standard DSC or exponential loss alone, particularly for small and boundary-ambiguous OARs.
  • The uncertainty maps derived from ensemble variance showed high correlation with mis-segmented regions, indicating strong potential for clinical guidance in refinement.
  • The method demonstrated robustness across diverse datasets and provided actionable uncertainty information without additional training or inference cost.
Figure 2: Overview of our proposed framework for accurate OARs segmentation. We first use different Segmental Linear Functions (SLFs) to transform the intensity of an input image respectively, which obtains good visibility of different OARs. Then a novel network 3D-SepNet that leverages intra-slice
Figure 2: Overview of our proposed framework for accurate OARs segmentation. We first use different Segmental Linear Functions (SLFs) to transform the intensity of an input image respectively, which obtains good visibility of different OARs. Then a novel network 3D-SepNet that leverages intra-slice

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.