Skip to main content
QUICK REVIEW

[Paper Review] Autonomous Fault Detection in Self-Healing Systems using Restricted Boltzmann Machines

Christopher Schneider, Adam Barker|arXiv (Cornell University)|Jan 7, 2015
Neural Networks and Reservoir ComputingComputer Science24 references7 citations
TL;DR

This paper proposes a novel autonomous fault detection approach in self-healing systems using Restricted Boltzmann Machines (RBMs) and contrastive divergence learning to predict feature behavior sequences from historical system data. By comparing predicted vs. actual feature states, the method identifies fault root causes without human intervention, achieving improved performance over prior HMM and ANN-based methods in detecting and ranking potential causes with a 75% harmonic mean accuracy in evaluation.

ABSTRACT

Autonomously detecting and recovering from faults is one approach for reducing the operational complexity and costs associated with managing computing environments. We present a novel methodology for autonomously generating investigation leads that help identify systems faults, and extends our previous work in this area by leveraging Restricted Boltzmann Machines (RBMs) and contrastive divergence learning to analyse changes in historical feature data. This allows us to heuristically identify the root cause of a fault, and demonstrate an improvement to the state of the art by showing feature data can be predicted heuristically beyond a single instance to include entire sequences of information.

Motivation & Objective

  • To reduce operational costs and human oversight in large-scale computing environments by enabling autonomous fault detection and root cause identification.
  • To overcome limitations of reactive, human-dependent recovery strategies in self-healing systems by introducing a predictive, unsupervised learning approach.
  • To extend prior work using HMMs and ANNs by enabling multi-step prediction of feature sequences through RBM-based modeling.
  • To evaluate the performance of RBM-based fault detection against existing methods like HMMs and Naïve Bayes in identifying fault sources accurately.
  • To explore the feasibility of transitioning from reactive to proactive fault detection using sequence prediction and feature locality analysis.

Proposed method

  • The method employs Restricted Boltzmann Machines (RBMs) trained via contrastive divergence learning on historical system configuration and performance data.
  • Feature data is collected periodically from the system using WMI and stored with unique identifiers to track changes over time.
  • Fitness functions are applied to classify feature states as valid or invalid based on learned expectations from the RBM model.
  • The system compares predicted feature states (from RBM) with actual observed states to detect anomalies and generate fault investigation leads.
  • A fault diagnosis framework (ADF) uses the discrepancy between predicted and actual values to rank potential root causes in order of likelihood.
  • The approach leverages unsupervised learning to build internal models of normal behavior without requiring pre-labeled fault data or expert-defined rules.

Experimental results

Research questions

  • RQ1Can RBMs trained via contrastive divergence learning effectively predict sequences of system feature behavior to detect faults autonomously?
  • RQ2How does the performance of the RBM-based fault detection method compare to prior approaches using HMMs and ANNs in identifying fault root causes?
  • RQ3To what extent can the system predict future feature states beyond a single instance, enabling proactive fault detection?
  • RQ4Does the inclusion of feature locality analysis improve the accuracy and reliability of fault diagnosis in distributed or complex systems?
  • RQ5Can the method reduce operational costs in large-scale IT environments by minimizing human supervision in fault detection and recovery?

Key findings

  • The RBM-based approach achieved a harmonic mean performance of 75% across multiple evaluation metrics, outperforming both HMM and Naïve Bayes methods in fault diagnosis accuracy.
  • The system successfully identified the correct root cause (network adapter throughput change) in 75% of test cases when sufficient training data was available.
  • With fewer configuration samples, the system’s accuracy dropped to 14%, indicating sensitivity to data sparsity and the need for adequate training data.
  • The method demonstrated the ability to predict entire sequences of feature behavior, enabling a shift from reactive to proactive fault detection.
  • The use of fitness functions allowed the system to autonomously build expectations of normal behavior without requiring pre-fabricated models or human input.
  • The results suggest that RBM-based prediction can support self-adaptive primitives for fault localization and may enable future integration with feature locality detection techniques.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.