[Paper Review] Axion Dark Matter Search with Interferometric Gravitational Wave Detectors
This paper proposes using the Fabry-Pérot cavities in interferometric gravitational wave detectors—such as Advanced LIGO, Cosmic Explorer, and DECIGO—to search for axion dark matter by measuring differential phase shifts between left- and right-circularly polarized photons induced by axion-photon coupling. The method achieves sensitivities of $ g_{\text{a}\gamma} \simeq 8 \times 10^{-13}~\text{GeV}^{-1} $ (for Cosmic-Explorer-like) and $ 4 \times 10^{-14}~\text{GeV}^{-1} $ (for Advanced LIGO-like) at axion masses $ m \simeq 3 \times 10^{-13} $ eV and $ 2 \times 10^{-15} $ eV, respectively, without degrading gravitational wave detection sensitivity.
Axion dark matter differentiates the phase velocities of the circular-polarized photons. In Phys.Rev.Lett. 123 (2019) no.11, 111301, we have proposed a scheme to measure the phase difference by using a linear optical cavity. If the scheme is applied to the Fabry-Pérot arm of Advanced LIGO-like (Cosmic-Explorer-like) gravitational wave detector, the potential sensitivity to the axion-photon coupling constant, $g_{ ext{a}γ}$, reaches $g_{ ext{a}γ} \simeq 8 imes10^{-13} ext{GeV}^{-1}\, (4 imes 10^{-14} ext{GeV}^{-1})$ at the axion mass $m \simeq 3 imes 10^{-13}$ eV ($2 imes10^{-15}$ eV) and remains at around this sensitivity for 3 orders of magnitude in mass. Furthermore, its sensitivity has a sharp peak reaching $g_{ ext{a}γ} \simeq 10^{-14} ext{GeV}^{-1}\ (8 imes10^{-17} ext{GeV}^{-1})$ at $m = 1.563 imes10^{-10}$ eV ($1.563 imes10^{-11}$ eV). This sensitivity can be achieved without loosing any sensitivity to gravitational waves.
Motivation & Objective
- To develop a new method for detecting axion dark matter using existing interferometric gravitational wave detectors without modifying their core functionality.
- To overcome the limitations of conventional axion searches that require strong magnetic fields and superconducting magnets.
- To exploit the phase velocity difference between circularly polarized photons induced by axion-photon coupling in a Fabry-Pérot cavity.
- To achieve shot-noise-limited sensitivity to the axion-photon coupling constant $ g_{\text{a}\gamma} $ across a broad axion mass range.
- To demonstrate that gravitational wave detectors can simultaneously search for axions and detect gravitational waves without sensitivity loss.
Proposed method
- The method uses a linear Fabry-Pérot cavity in gravitational wave detectors to detect phase velocity differences between left- and right-circularly polarized photons caused by axion dark matter.
- The axion-induced phase shift $ \delta\phi(t) $ is modeled via a response function $ H_{\text{a}}(m) $ that depends on cavity length, mirror reflectivity, and axion mass.
- Signal is extracted by measuring polarization modulation in the detection port, with optimal sensitivity achieved at cavity resonance (free spectral range) and in the low-mass regime where $ mL \ll 1 $.
- The signal-to-noise ratio (SNR) is calculated under shot-noise-limited conditions, with distinct scaling depending on whether observation time $ T_{\text{obs}} $ is shorter or longer than the axion oscillation coherent time $ \tau $.
- Detection port (a) is optimal for critical-coupled cavities, while port (b) is better for over-coupled configurations.
- The scheme is designed to be compatible with existing interferometer architectures, with axion signals extracted in the same way as gravitational wave signals, minimizing hardware modifications.
Experimental results
Research questions
- RQ1Can existing interferometric gravitational wave detectors be repurposed to search for axion dark matter without degrading their primary gravitational wave detection sensitivity?
- RQ2What is the theoretical sensitivity limit of axion-photon coupling $ g_{\text{a}\gamma} $ achievable using Fabry-Pérot cavities in gravitational wave detectors?
- RQ3How does the axion-induced phase shift between circularly polarized photons scale with axion mass and cavity parameters?
- RQ4Can shot noise be the dominant limitation in this axion search, and how does the SNR depend on observation time relative to axion coherence time?
- RQ5What are the dominant technical noise sources, and can they be suppressed below the shot noise level in realistic detector configurations?
Key findings
- The method achieves a sensitivity of $ g_{\text{a}\gamma} \simeq 8 \times 10^{-13}~\text{GeV}^{-1} $ for Cosmic-Explorer-like detectors at $ m \simeq 3 \times 10^{-13} $ eV, improving on current limits.
- For Advanced LIGO-like detectors, the sensitivity reaches $ g_{\text{a}\gamma} \simeq 4 \times 10^{-14}~\text{GeV}^{-1} $ at $ m \simeq 2 \times 10^{-15} $ eV.
- The sensitivity remains high over a broad axion mass range, with a sharp peak of $ g_{\text{a}\gamma} \simeq 10^{-14}~\text{GeV}^{-1} $ at $ m = 1.563 \times 10^{-10} $ eV for Cosmic-Explorer-like detectors.
- The method maintains full gravitational wave detection sensitivity because common-phase noise from mirror displacements or GWs cancels out in the differential phase measurement.
- Roll motion of mirrors is identified as a potential noise source, but its spectrum is estimated to be below the shot noise level in aLIGO ($ \sqrt{S_{\text{roll}}} < 3 \times 10^{-26}~\text{rad}/\sqrt{\text{Hz}} $) for $ m > 10^{-14} $ eV.
- The scheme is compatible with existing detectors, with axion signals extractable behind signal recycling mirrors without modifying the main interferometer.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.