[Paper Review] Bayesian modelling and quantification of Raman spectroscopy
This paper proposes a Bayesian hierarchical model using sequential Monte Carlo (SMC) to jointly estimate Raman peak parameters (amplitude, FWHM, position) and a smooth baseline, enabling robust multivariate calibration and improved limit of detection (LOD) estimation. The method models peaks as Lorentzian, Gaussian, or pseudo-Voigt functions and uses penalized B-splines for baseline correction, with uncertainty propagation through posterior inference to enhance quantification accuracy in complex spectra.
Raman spectroscopy can be used to identify molecules such as DNA by the characteristic scattering of light from a laser. It is sensitive at very low concentrations and can accurately quantify the amount of a given molecule in a sample. The presence of a large, nonuniform background presents a major challenge to analysis of these spectra. To overcome this challenge, we introduce a sequential Monte Carlo (SMC) algorithm to separate the observed spectrum into a series of peaks plus a smoothly-varying baseline, corrupted by additive white noise. The peaks are modelled using Lorentzian or Gaussian broadening functions, while the baseline is estimated using a penalised cubic spline. This latent continuous representation accounts for differences in resolution between measurements. By incorporating this representation in a Bayesian model, we can quantify the relationship between molecular concentration and peak intensity, thereby providing an improved estimate of the limit of detection (LOD), which is of major importance in analytical chemistry.
Motivation & Objective
- Address the challenge of nonuniform, variable baselines in Raman spectroscopy that hinder accurate peak quantification.
- Develop a scalable, uncertainty-aware method for multivariate calibration that avoids bias from pre-processing baseline subtraction.
- Improve the estimation of the limit of detection (LOD) by incorporating uncertainty in peak and baseline parameters.
- Enable robust, incremental updating of posterior distributions as new data becomes available, supporting real-time or adaptive analysis.
- Provide a flexible, open-source framework for quantifying low-concentration molecules in complex samples using Bayesian inference.
Proposed method
- Employ a sequential Monte Carlo (SMC) algorithm to sample from the joint posterior distribution of peak parameters and baseline.
- Model Raman peaks using a mixture of Lorentzian, Gaussian, and pseudo-Voigt functions to capture peak broadening and shape variations.
- Use penalized B-splines to represent the smooth, non-uniform baseline, allowing flexible and non-parametric estimation.
- Incorporate informative priors derived from quantum mechanical predictions (e.g., TD-DFT) to improve model identifiability.
- Formulate a Bayesian hierarchical regression model linking peak intensity to molecular concentration, enabling multivariate calibration.
- Use highest posterior density (HPD) intervals to quantify uncertainty in key parameters, including LOD and FWHM.
Experimental results
Research questions
- RQ1How can baseline correction and peak detection be jointly modeled to reduce bias from pre-processing steps in Raman spectroscopy?
- RQ2What is the impact of modeling peak shape (Lorentzian, Gaussian, pseudo-Voigt) on the accuracy of concentration quantification?
- RQ3Can a sequential Monte Carlo algorithm provide scalable and robust inference for complex Raman spectra with overlapping peaks?
- RQ4How does uncertainty in baseline and peak parameters affect the estimation of the limit of detection (LOD) for low-concentration analytes?
- RQ5To what extent can Bayesian hierarchical modeling improve multivariate calibration compared to univariate or classical least squares methods?
Key findings
- The model successfully estimated the limit of detection (LOD) for TAMRA dye at concentrations between 6 and 16 picomolar (pM), with 95% HPD intervals confirming detectability at 0.65 nM for 17 out of 34 peaks.
- At 0.13 nM, peaks at 460 cm⁻¹ and 965 cm⁻¹ had upper bounds for LOD above the concentration, indicating they were not detectable, consistent with visual inspection of spectra.
- The 1455 cm⁻¹ peak was underestimated by the model, highlighting sensitivity to peak shape and baseline interaction in low-signal regimes.
- The algorithm demonstrated robustness to local maxima and enabled incremental posterior updates, supporting scalability and adaptability in data-rich settings.
- The use of pseudo-Voigt functions improved peak shape modeling compared to purely Gaussian or Lorentzian assumptions, especially in overlapping peak regions.
- The open-source R package implementation enables reproducible analysis and extension to multiplexed or spatially resolved Raman mapping applications.
Read this paper