QUICK REVIEW
[Paper Review] Beam Test Results for New Full-scale GEM Prototypes for a Future Upgrade of the CMS High-eta Muon System
D. Abbaneo, M. Abbrescia|arXiv (Cornell University)|Nov 16, 2012
TL;DR
This paper presents beam test results for four full-scale Triple-GEM prototypes designed for the CMS high-eta muon system upgrade, demonstrating a new fast assembly technique and a novel zigzag strip readout with 2 mm pitch. The key result is a spatial resolution of 73 μm, showing potential for reducing readout channel count by ~3× and lowering electronics cost while maintaining high performance in high-rate, high-eta environments.
ABSTRACT
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for upgrading the CMS forward muon system in the 1.5
Motivation & Objective
- To develop and test full-scale GEM detectors for the CMS forward muon system upgrade in the 1.5<|η|<2.4 region.
- To implement a faster, spacer-free assembly technique for mass production of large-area GEM chambers.
- To evaluate a zigzag strip readout geometry with 2 mm pitch as a cost-reducing alternative to standard straight strips.
- To demonstrate high spatial resolution and detection efficiency under high-rate beam conditions.
- To validate the feasibility of GEMs for replacing descoped Resistive Plate Chambers in the high-η region.
Proposed method
- Four full-scale Triple-GEM detectors were fabricated using a new mechanical stretching technique without spacers or glue, enabling faster, scalable production.
- The detectors feature a 3/1/2/1 mm electrode gap configuration with 35 HV sectors on 50 μm Kapton foils clad with 5 μm copper.
- A zigzag strip readout with 2 mm pitch and 0.5/1 mm zigzag periods was implemented on a 10×10 cm² PCB for beam testing.
- Two 10×10 cm² GEM detectors with zigzag readout were stacked and operated in a 70:30 Ar/CO₂ gas mixture at the CERN SPS H4 beam line.
- Position resolution was measured using the barycenter method on pulse-height-weighted strip clusters from the Scalable Readout System (RD51 APV25 hybrids).
- Detection efficiency and timing performance were evaluated using 25 ns bunch crossing measurements.
Experimental results
Research questions
- RQ1Can a fast, spacer-free assembly technique enable reliable and scalable production of large-area GEM detectors for the CMS upgrade?
- RQ2Does a zigzag strip readout with 2 mm pitch maintain sufficient spatial resolution for high-precision tracking in the high-η region?
- RQ3Can the zigzag readout reduce the number of required electronic channels by a factor of three compared to standard straight strips?
- RQ4What is the achievable spatial resolution and detection efficiency of full-scale GEM prototypes under high-rate beam conditions?
- RQ5How does the performance of the new GEM design compare to previous prototypes in terms of rate capability and radiation hardness?
Key findings
- The new fast assembly technique successfully produced full-scale GEM detectors without spacers or glue, enabling scalable production for the CMS upgrade.
- The full-scale GEM detectors achieved 98% detection efficiency on plateau in beam tests at zero magnetic field.
- A direct timing measurement showed ~95% efficiency per 25 ns bunch crossing, confirming high-rate capability.
- The zigzag strip readout with 2 mm pitch achieved a spatial resolution of 73 μm, measured as the RMS of position differences between two stacked detectors.
- The resolution of 73 μm was achieved despite a 2 mm strip pitch, indicating that charge-sharing across slanted zigzag strips enhances transverse resolution.
- The zigzag readout design could reduce the number of required readout channels by approximately a factor of three, significantly lowering electronics cost.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.