[Paper Review] The Pierre Auger Observatory Upgrade - Preliminary Design Report

The Pierre Auger Collaboration, A. Aab|arXiv (Cornell University)|Apr 13, 2016
Particle Detector Development and PerformancePhysics and Astronomy103 citations
TL;DR

This paper presents the AugerPrime upgrade plan for the Pierre Auger Observatory, detailing the detector additions (SSD, UMD), electronics upgrades, extended Fluorescence Detector duty cycle, and project organization, cost, and schedule.

ABSTRACT

The Pierre Auger Observatory has begun a major Upgrade of its already impressive capabilities, with an emphasis on improved mass composition determination using the surface detectors of the Observatory. Known as AugerPrime, the upgrade will include new 4 m$^2$ plastic scintillator detectors on top of all 1660 water-Cherenkov detectors, updated and more flexible surface detector electronics, a large array of buried muon detectors, and an extended duty cycle for operations of the fluorescence detectors. This Preliminary Design Report was produced by the Collaboration in April 2015 as an internal document and information for funding agencies. It outlines the scientific and technical case for AugerPrime. We now release it to the public via the arXiv server. We invite you to review the large number of fundamental results already achieved by the Observatory and our plans for the future.

Motivation & Objective

  • Explain the scientific motivation for upgrading the Pierre Auger Observatory to improve mass composition determination at the highest energies.
  • Describe the proposed detector enhancements (scintillator surface detectors, underground muon detectors) and electronics upgrades.
  • Outline the plan to extend the fluorescence detector duty cycle and its impact on data collection.
  • Assess project organization, risk management, costs, and deployment schedule for the upgrade.

Proposed method

  • Introduce a complementary plastic scintillator plane atop each Water-Cherenkov Detector to sample shower components with different responses.
  • Upgrade surface detector electronics to process both WCD and SSD signals with higher sampling rate, timing accuracy, and dynamic range.
  • Implement the AMIGA underground muon detectors as the UMD component to measure muon content and validate methods.
  • Extend Fluorescence Detector operations to higher night sky background periods to increase duty cycle by ~50%.
  • Maintain existing detector operations with minimal downtime and adapt central data acquisition and monitoring systems accordingly.

Experimental results

Research questions

  • RQ1What is the sensitivity gain in mass composition determination from adding the SSD and UMD to the existing array?
  • RQ2How does the extended FD duty cycle improve exposure and statistical power for high-energy cosmic ray measurements?
  • RQ3Can direct muon measurements from UMD validate and calibrate muon extraction methods from SSD/WCD data?
  • RQ4What are the cost, schedule, and organizational requirements to complete the AugerPrime upgrade by 2018?
  • RQ5How will the upgraded detector suite constrain hadronic interaction models and potential new physics at ultrahigh energies?

Key findings

  • The upgrade targets improved mass composition determination for events across the array, enabling shower-by-shower mass information.
  • Projected total upgrade cost is US$ 15.2 M with contingency (infrastructure included); US$ 12.7 M without infrastructure costs.
  • AMIGA underground muon detectors will serve as the UMD and cost about US$ 1.6 M (without infrastructure costs).
  • The FD duty cycle is expected to increase by about 50% through extended operation during brighter nights.
  • The upgrade aims to double the event statistics by 2016–18 and reduce systematic uncertainties related to hadronic shower modeling.
  • The new detectors enable cross-checks with the Telescope Array and improve proton fraction sensitivity in the flux suppression region.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.