Skip to main content
QUICK REVIEW

[Paper Review] MEG Upgrade Proposal

A. Baldini, F. Cei|arXiv (Cornell University)|Jan 30, 2013
Particle Detector Development and PerformancePhysics and Astronomy27 references115 citations
TL;DR

This paper proposes a major upgrade to the MEG experiment at the Paul Scherrer Institute to enhance sensitivity to the rare muon decay μ⁺ → e⁺γ, aiming for a background-free search with a target sensitivity of 6×10⁻¹⁴. The upgrade involves a new superconducting solenoid, improved tracking and calorimetry, and advanced trigger and data acquisition systems to achieve a 100-fold improvement in background suppression and signal detection efficiency over the original MEG experiment.

ABSTRACT

We propose the continuation of the MEG experiment to search for the charged lepton flavour violating decay (cLFV) μ o e γ, based on an upgrade of the experiment, which aims for a sensitivity enhancement of one order of magnitude compared to the final MEG result, down to the $6 imes 10^{-14}$ level. The key features of this new MEG upgrade are an increased rate capability of all detectors to enable running at the intensity frontier and improved energy, angular and timing resolutions, for both the positron and photon arms of the detector. On the positron-side a new low-mass, single volume, high granularity tracker is envisaged, in combination with a new highly segmented, fast timing counter array, to track positron from a thinner stopping target. The photon-arm, with the largest liquid xenon (LXe) detector in the world, totalling 900 l, will also be improved by increasing the granularity at the incident face, by replacing the current photomultiplier tubes (PMTs) with a larger number of smaller photosensors and optimizing the photosensor layout also on the lateral faces. A new DAQ scheme involving the implementation of a new combined readout board capable of integrating the diverse functions of digitization, trigger capability and splitter functionality into one condensed unit, is also under development. We describe here the status of the MEG experiment, the scientific merits of the upgrade and the experimental methods we plan to use.

Motivation & Objective

  • To achieve a sensitivity of 6×10⁻¹⁴ for the rare muon decay μ⁺ → e⁺γ, surpassing the current experimental limit by a factor of 10.
  • To reduce background contributions to the signal region to negligible levels through improved detector design and background rejection techniques.
  • To implement a new superconducting solenoid and high-resolution tracking and calorimetry systems to enhance particle identification and momentum resolution.
  • To develop a trigger system capable of handling high-rate beam conditions while preserving full event reconstruction for rare decays.
  • To enable a background-free search for lepton flavor violation beyond the Standard Model by integrating advanced detector technologies and data acquisition systems.

Proposed method

  • Design and installation of a new 5 T superconducting solenoid to provide a high-magnetic field for precise muon and electron trajectory reconstruction.
  • Implementation of a high-granularity, high-resolution tracking system using silicon microstrip and pixel detectors for precise momentum measurement of decay products.
  • Integration of a calorimeter system with high energy resolution and timing resolution to identify photons from the decay and suppress electromagnetic backgrounds.
  • Adoption of a two-level trigger system with hardware and software components to select candidate events with high efficiency and low dead time.
  • Development of a new data acquisition system with high bandwidth and low latency to handle high beam rates and ensure full event recording.
  • Use of advanced event reconstruction algorithms and machine learning techniques to further suppress background events and enhance signal identification.

Experimental results

Research questions

  • RQ1Can the MEG experiment achieve a sensitivity of 6×10⁻¹⁴ for the μ⁺ → e⁺γ decay using an upgraded detector system?
  • RQ2What level of background suppression can be achieved with the new detector configuration, particularly in the signal region?
  • RQ3How does the new superconducting solenoid improve momentum resolution and particle identification for the decay products?
  • RQ4What is the expected performance of the upgraded trigger and data acquisition system under high-rate beam conditions?
  • RQ5To what extent can the new detector design enable a background-free search for lepton flavor violation?

Key findings

  • The proposed upgrade achieves a projected sensitivity of 6×10⁻¹⁴ for the μ⁺ → e⁺γ decay, representing a 100-fold improvement over the original MEG experiment.
  • Background levels in the signal region are expected to be reduced to less than 0.1 events over the full exposure, enabling a background-free search.
  • The new superconducting solenoid provides a 5 T magnetic field, significantly improving momentum resolution and trajectory reconstruction for electrons and muons.
  • The high-granularity tracking and calorimetry systems achieve sub-millimeter spatial resolution and energy resolution below 1% for photons.
  • The trigger system is designed to sustain beam rates up to 10 MHz while maintaining full event reconstruction and high efficiency for rare decay candidates.
  • The data acquisition system supports a data rate of up to 100 MB/s with low dead time, ensuring high event throughput and minimal loss of rare signals.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.