Skip to main content
QUICK REVIEW

[Paper Review] Mu2e Technical Design Report

L. Bartoszek, E. Barnes|arXiv (Cornell University)|Jan 21, 2015
Particle Detector Development and PerformancePhysics and Astronomy119 citations
TL;DR

The Mu2e Technical Design Report presents the detailed engineering and physics design of the Mu2e experiment at Fermilab, which aims to search for charged lepton flavor violation via coherent muon-to-electron conversion in a nitrogen target. With a sensitivity four orders of magnitude better than current limits, the experiment probes new physics models beyond the Standard Model, including those predicting lepton flavor violation at mass scales inaccessible to the LHC.

ABSTRACT

The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.

Motivation & Objective

  • To design a high-sensitivity experiment to search for charged lepton flavor violation (CLFV) via coherent muon-to-electron conversion in nuclei.
  • To achieve a sensitivity approximately four orders of magnitude better than the current world-leading limits for the process μ⁻N → e⁻N.
  • To probe new physics models that predict lepton flavor violation, including those with heavy neutral leptoquarks, Z′ bosons, or supersymmetric particles.
  • To fulfill the technical and scientific requirements for DOE CD-2 approval, ensuring feasibility and performance of the proposed experiment.
  • To establish a detector system capable of identifying rare electron signals against a low background, using advanced particle identification and tracking techniques.

Proposed method

  • Design of a high-intensity muon beamline at Fermilab to deliver 8×10^13 muons per second to a target with a 100% duty factor.
  • Implementation of a high-precision solenoid-based magnetic spectrometer to measure electron momentum and trajectory with sub-permil resolution.
  • Use of a low-background, high-purity liquid nitrogen target to maximize coherent conversion signal and minimize background from incoherent processes.
  • Employment of a two-stage particle identification system combining a transition radiation detector and a calorimeter to distinguish electrons from pions and other background particles.
  • Application of advanced tracking and vertex reconstruction algorithms to identify the primary vertex of the electron production and suppress cosmic ray and beam-related backgrounds.
  • Integration of detailed Monte Carlo simulations and background modeling to predict and optimize signal-to-background ratios across the full kinematic range.

Experimental results

Research questions

  • RQ1What is the maximum achievable sensitivity for the coherent μ⁻N → e⁻N conversion process using the proposed Mu2e detector configuration?
  • RQ2How can background contributions from pion misidentification, cosmic rays, and beam-related processes be minimized to achieve the required signal-to-background ratio?
  • RQ3What are the key technical and engineering challenges in constructing a high-intensity, low-background muon beamline and spectrometer system?
  • RQ4How does the detector performance compare to the required sensitivity for probing new physics models beyond the Standard Model?
  • RQ5What are the dominant sources of systematic uncertainty in the measurement, and how can they be controlled through design and calibration?

Key findings

  • The Mu2e experiment is designed to achieve a sensitivity of approximately 6×10⁻¹-eight for the μ⁻N → e⁻N conversion process, representing a four-order-of-magnitude improvement over the current best limit.
  • The detector system is projected to achieve a momentum resolution of better than 0.2% for electrons, enabling precise kinematic reconstruction and background suppression.
  • Background levels are expected to be dominated by cosmic rays and beam-related processes, with a total expected background rate of less than 0.1 events per year in the signal region.
  • The use of a liquid nitrogen target with high purity and low density ensures a high coherent-to-incoherent conversion ratio, enhancing the signal yield.
  • Monte Carlo simulations confirm that the particle identification system can suppress pion backgrounds by a factor of 10⁶, enabling effective signal isolation.
  • The technical design has been validated through extensive simulations and engineering studies, satisfying the requirements for DOE CD-2 approval.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.