Skip to main content
QUICK REVIEW

[Paper Review] Bidirectional Copy-Paste for Semi-Supervised Medical Image Segmentation

Yunhao Bai, Duowen Chen|arXiv (Cornell University)|May 1, 2023
Advanced Neural Network ApplicationsComputer Science12 citations
TL;DR

This paper introduces Bidirectional Copy-Paste (BCP) within a Mean Teacher framework to align labeled and unlabeled data distributions for semi-supervised medical image segmentation, yielding large Dice gains (e.g., up to 21% on ACDC with 5% labels).

ABSTRACT

In semi-supervised medical image segmentation, there exist empirical mismatch problems between labeled and unlabeled data distribution. The knowledge learned from the labeled data may be largely discarded if treating labeled and unlabeled data separately or in an inconsistent manner. We propose a straightforward method for alleviating the problem - copy-pasting labeled and unlabeled data bidirectionally, in a simple Mean Teacher architecture. The method encourages unlabeled data to learn comprehensive common semantics from the labeled data in both inward and outward directions. More importantly, the consistent learning procedure for labeled and unlabeled data can largely reduce the empirical distribution gap. In detail, we copy-paste a random crop from a labeled image (foreground) onto an unlabeled image (background) and an unlabeled image (foreground) onto a labeled image (background), respectively. The two mixed images are fed into a Student network and supervised by the mixed supervisory signals of pseudo-labels and ground-truth. We reveal that the simple mechanism of copy-pasting bidirectionally between labeled and unlabeled data is good enough and the experiments show solid gains (e.g., over 21% Dice improvement on ACDC dataset with 5% labeled data) compared with other state-of-the-arts on various semi-supervised medical image segmentation datasets. Code is available at https://github.com/DeepMed-Lab-ECNU/BCP}.

Motivation & Objective

  • Motivate and address distribution mismatch between a small labeled set and a large unlabeled set in semi-supervised medical segmentation.
  • Propose a simple, consistent learning mechanism that transfers knowledge bidirectionally between labeled and unlabeled data.
  • Leverage copy-paste augmentations to induce common semantics and reduce empirical distribution gaps.
  • Demonstrate strong empirical gains across multiple datasets and ablations without adding extra trainable parameters.

Proposed method

  • Operate in a Mean Teacher framework with a Teacher and a Student network.
  • Generate two mixed inputs by bidirectionally copy-pasting crops between labeled and unlabeled images (inward and outward).
  • Supervise the Student using bidirectional mixed supervisory signals derived from Teacher pseudo-labels and labeled ground-truths.
  • Use a zero-centered copy-mask to define cropped regions and a beta parameter to control foreground size (beta ≈ 2/3).
  • Compute losses on the mixed inputs with a labeled/unlabeled mask to balance supervision (alpha controls unlabeled contribution).
  • Update the Teacher via exponential moving average of the Student parameters after each iteration.

Experimental results

Research questions

  • RQ1Does bidirectional copy-paste between labeled and unlabeled data reduce empirical distribution mismatch in semi-supervised medical segmentation?
  • RQ2How do inward and outward copy-paste directions influence learning of common semantics and final segmentation accuracy?
  • RQ3What is the impact of masking strategy, crop size, and loss weighting on performance across datasets?
  • RQ4Can the proposed method outperform existing semi-supervised approaches without extra model complexity?

Key findings

  • BCP substantially reduces the performance gap between labeled and unlabeled data across datasets.
  • On ACDC with 5% labeled data, the method achieves up to 21% Dice improvement over baselines.
  • On LA, Pancreas-NIH, and ACDC, BCP consistently surpasses state-of-the-art semi-supervised methods across Dice, Jaccard, and boundary metrics (e.g., 95HD and ASD).
  • Ablation studies show bidirectional directions (Inward and Outward) outperform single-direction Copied-Paste and CP-only variants.
  • Pre-training with copy-paste on labeled data and lower alpha values for unlabeled supervision improve pseudo-label quality and final Dice.
  • The method does not add new trainable parameters and maintains comparable computational cost to baselines.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.