Skip to main content
QUICK REVIEW

[Paper Review] Bridging 2D and 3D Segmentation Networks for Computation Efficient Volumetric Medical Image Segmentation: An Empirical Study of 2.5D Solutions

Yichi Zhang, Qingcheng Liao|arXiv (Cornell University)|Oct 13, 2020
Advanced Neural Network ApplicationsComputer Science6 citations
TL;DR

This paper proposes a comprehensive empirical study of 2.5D medical image segmentation methods that bridge 2D and 3D CNNs to achieve computation-efficient volumetric segmentation. By evaluating three categories—multi-view fusion, inter-slice feature incorporation, and 2D/3D feature fusion—on CT and MRI datasets, it demonstrates that 2.5D methods can match or exceed 3D CNN performance with significantly reduced computation and parameters, especially on anisotropic volumes where 3D CNNs underperform.

ABSTRACT

Recently, deep convolutional neural networks have achieved great success for medical image segmentation. However, unlike segmentation of natural images, most medical images such as MRI and CT are volumetric data. In order to make full use of volumetric information, 3D CNNs are widely used. However, 3D CNNs suffer from higher inference time and computation cost, which hinders their further clinical applications. Additionally, with the increased number of parameters, the risk of overfitting is higher, especially for medical images where data and annotations are expensive to acquire. To issue this problem, many 2.5D segmentation methods have been proposed to make use of volumetric spatial information with less computation cost. Despite these works lead to improvements on a variety of segmentation tasks, to the best of our knowledge, there has not previously been a large-scale empirical comparison of these methods. In this paper, we aim to present a review of the latest developments of 2.5D methods for volumetric medical image segmentation. Additionally, to compare the performance and effectiveness of these methods, we provide an empirical study of these methods on three representative segmentation tasks involving different modalities and targets. Our experimental results highlight that 3D CNNs may not always be the best choice. Despite all these 2.5D methods can bring performance gains to 2D baseline, not all the methods hold the benefits on different datasets. We hope the results and conclusions of our study will prove useful for the community on exploring and developing efficient volumetric medical image segmentation methods.

Motivation & Objective

  • To address the high computational cost and overfitting risks of 3D CNNs in volumetric medical image segmentation.
  • To evaluate and compare the performance of various 2.5D methods across different medical imaging modalities and anatomical targets.
  • To provide a large-scale empirical benchmark for 2.5D methods, filling the gap in systematic comparison across datasets and tasks.
  • To guide researchers in selecting optimal 2.5D architectures based on dataset characteristics and computational constraints.

Proposed method

  • Categorizing 2.5D methods into three types: multi-view fusion, incorporating inter-slice information via RNNs or attention mechanisms, and fusing 2D and 3D features at encoding or output stages.
  • Using 2D and 3D U-Net as backbone networks for consistent comparison across all methods.
  • Implementing multi-view fusion by training separate 2D networks on axial, sagittal, and coronal views and aggregating predictions.
  • Integrating inter-slice context using 1D or 3D RNNs and squeeze-and-excitation (SE) blocks to model spatial dependencies across slices.
  • Fusing 2D and 3D features by concatenating or element-wise adding features from 2D and 3D encoders or final outputs.
  • Conducting fair comparisons using identical hyperparameters, data augmentation, and training protocols across all models.

Experimental results

Research questions

  • RQ1Does 2.5D segmentation consistently outperform 2D and 3D baselines across diverse medical imaging tasks?
  • RQ2Which 2.5D method architecture yields the best trade-off between performance, inference speed, and model complexity?
  • RQ3How do 2.5D methods perform on anisotropic volumetric data where 3D CNNs are less effective?
  • RQ4What is the relative impact of feature fusion location (encoding vs. output) on segmentation accuracy and training efficiency?
  • RQ5Can 2.5D methods achieve performance comparable to 3D CNNs while reducing parameter count and training time?

Key findings

  • All 2.5D methods improved upon 2D U-Net baseline, with multi-view fusion achieving performance comparable to 3D U-Net but requiring training of three separate networks.
  • For cardiac MRI, fusing features at the output stage outperformed encoding-stage fusion; for spleen CT and prostate MRI, no single fusion method dominated across all tasks.
  • RNN- and attention-based inter-slice integration improved performance over naive multi-slice input, but gains varied across datasets and were not consistently superior.
  • Fusing 2D and 3D features at the encoding stage offered better accuracy with lower computational cost, while output-stage fusion accelerated 3D network training but increased inference time.
  • All 2.5D methods had significantly fewer parameters and faster training than 3D U-Net—e.g., 2D U-Net had 0.487M parameters vs. 3D U-Net’s 1.403M—and training time was reduced to 1.00x to 2.32x of the 2D baseline.
  • On anisotropic volumes (e.g., CT with low slice resolution), 3D CNNs often underperformed compared to 2.5D methods, indicating that 3D models may not always be optimal despite their volumetric perception.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.