Skip to main content
QUICK REVIEW

[Paper Review] Calib-Anything: Zero-training LiDAR-Camera Extrinsic Calibration Method Using Segment Anything

Zhaotong Luo, Guohang Yan|arXiv (Cornell University)|Jun 5, 2023
Advanced Vision and ImagingComputer Science3 citations
TL;DR

This paper proposes Calib-Anything, a zero-training LiDAR-camera extrinsic calibration method that leverages the Segment Anything Model (SAM) for zero-shot semantic segmentation and optimizes extrinsic parameters by maximizing point cloud consistency in intensity, normal vectors, and segmentation classes within image masks. The method achieves comparable accuracy to learning-based approaches without fine-tuning, demonstrating strong generalization across datasets.

ABSTRACT

The research on extrinsic calibration between Light Detection and Ranging(LiDAR) and camera are being promoted to a more accurate, automatic and generic manner. Since deep learning has been employed in calibration, the restrictions on the scene are greatly reduced. However, data driven method has the drawback of low transfer-ability. It cannot adapt to dataset variations unless additional training is taken. With the advent of foundation model, this problem can be significantly mitigated. By using the Segment Anything Model(SAM), we propose a novel LiDAR-camera calibration method, which requires zero extra training and adapts to common scenes. With an initial guess, we opimize the extrinsic parameter by maximizing the consistency of points that are projected inside each image mask. The consistency includes three properties of the point cloud: the intensity, normal vector and categories derived from some segmentation methods. The experiments on different dataset have demonstrated the generality and comparable accuracy of our method. The code is available at https://github.com/OpenCalib/CalibAnything.

Motivation & Objective

  • To develop a target-free, automatic LiDAR-camera calibration method that requires no additional training or domain adaptation.
  • To overcome the limited transferability of data-driven calibration methods that rely on large, well-labeled datasets.
  • To leverage foundation models like SAM for zero-shot segmentation to enable calibration in diverse, real-world scenes.
  • To establish a robust, general-purpose calibration criterion based on point cloud attribute consistency within image masks.
  • To demonstrate comparable accuracy to state-of-the-art methods while maintaining zero-shot adaptability across datasets.

Proposed method

  • Utilizes the pre-trained Segment Anything Model (SAM) to generate zero-shot image segmentation masks without any fine-tuning.
  • Projects LiDAR point clouds onto each image mask using an initial extrinsic guess and evaluates consistency of point cloud attributes within each mask.
  • Defines three consistency metrics: intensity (standard deviation of reflectivity), normal vector (average pairwise dot product), and segmentation class (weighted sum of largest clusters).
  • Applies an adaptive function to penalize masks with too few points, improving robustness to sparse projections.
  • Optimizes extrinsic parameters by maximizing the weighted sum of consistency scores across all masks, with weights proportional to mask point count.
  • Employs a two-stage search: brute-force rotation search with large strides, followed by refined random search over 6D pose space to improve convergence.

Experimental results

Research questions

  • RQ1Can a foundation model like SAM enable zero-shot LiDAR-camera calibration without any additional training?
  • RQ2Can point cloud consistency in intensity, normal vectors, and segmentation classes serve as a reliable optimization objective for extrinsic calibration?
  • RQ3How does the proposed method perform in terms of accuracy and generalization across diverse datasets without fine-tuning?
  • RQ4Does the method outperform or match existing segmentation-based calibration approaches in accuracy while maintaining zero-shot adaptability?
  • RQ5Can the method effectively correct large initial extrinsic errors in real-world scenarios?

Key findings

  • On the KITTI dataset, the method achieves an L2 loss of 10.7 cm for translation and 0.174° for rotation, outperforming the prior segmentation-based method [19] which reported 20.2 cm and 0.34°.
  • On the authors' own dataset, the method achieves 12.8 cm translation and 0.203° rotation L2 loss, demonstrating strong generalization beyond KITTI.
  • The method reduces Huber loss for translation and rotation compared to [19], indicating better robustness to outliers.
  • Qualitative results show that the method successfully corrects an initial extrinsic error of approximately 5 degrees, restoring accurate point cloud projection onto image masks.
  • The consistency-based optimization criterion effectively identifies correct extrinsic parameters even when initial estimates are significantly off.
  • The method maintains high performance across datasets without retraining, confirming its zero-shot and generalizable nature.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.