Skip to main content
QUICK REVIEW

[Paper Review] Calibrations of SITELLE's first data release

Thomas Martin, Laurent Drissen|arXiv (Cornell University)|Jun 10, 2017
Stellar, planetary, and galactic studiesPhysics and Astronomy2 references5 citations
TL;DR

This paper presents a comprehensive calibration analysis of SITELLE’s first data release, detailing flux, wavelength, and astrometric calibration procedures. It identifies a -5% flux calibration bias and an 80 ± 5 km s⁻¹ absolute wavelength error due to imprecise laser calibration, with improvements planned for future releases using internal phase corrections and OH band measurements.

ABSTRACT

SITELLE is an imaging Fourier Transform Spectrometer installed at the Canada-France-Hawaii Telescope since July 2015. It delivers spectral cubes covering an 11'x11' field-of-view with a seeing-limited spatial resolution and a tunable spectral resolution (R=1-10 000) in selected passbands of the visible band (350-900 nm). We present an accurate picture of the calibration accuracy of SITELLE's first data release. To this purpose, most of the operations of the reduction pipeline (ORBS) are described in details.

Motivation & Objective

  • To evaluate the calibration accuracy of SITELLE’s first data release, focusing on flux, wavelength, and astrometric calibration.
  • To identify and quantify systematic biases in flux and wavelength calibration that affect data reliability.
  • To provide a detailed description of the ORBS pipeline operations impacting calibration quality.
  • To recommend external flux calibration checks and internal corrections for wavelength errors.
  • To lay the groundwork for improved calibration in future data releases using phase corrections and OH band measurements.

Proposed method

  • Application of the ORBS reduction pipeline to process interferometric cubes from SITELLE’s 2k×2k CCDs, including bias subtraction, flat-field correction, and image realignment.
  • Use of star positions in the field-of-view to compute alignment parameters and correct for optical misalignment between the two camera outputs.
  • Combination of interferometric cubes from both output ports to enhance signal-to-noise ratio and remove unmodulated background light.
  • Computation of phase correction using a discrete Fourier transform (DFT) of interferograms, with phase errors corrected to preserve instrument line shape (ILS).
  • Flux calibration via comparison with standard stars and correction for modulation efficiency, with residual 5% variability observed.
  • Wavelength calibration using a calibration laser at 543.5 nm, with velocity error quantified using the relation εᵥ = c·εσ/σ_laser, and correction via Meinel OH band fitting in sky spectra.

Experimental results

Research questions

  • RQ1What is the accuracy of SITELLE’s flux calibration in the first data release, and what are the dominant sources of error?
  • RQ2How does the phase correction process affect the instrument line shape and subsequent flux and wavelength calibration?
  • RQ3What is the magnitude of the absolute wavelength calibration bias, and how can it be corrected using sky lines?
  • RQ4To what extent are astrometric calibrations limited by optical distortions and catalog accuracy in the current release?
  • RQ5How can pixel-to-pixel wavelength and flux calibration errors be reduced in future data releases?

Key findings

  • The absolute flux calibration is biased by -5%, with a 5% variability observed between different observations.
  • The absolute wavelength calibration is biased by 80 ± 5 km s⁻¹ due to an imprecise laser wavelength (543.5 nm), with an error of 55 km s⁻¹ per 1 Å uncertainty.
  • Pixel-to-pixel wavelength calibration errors can reach up to 15 km s⁻¹ but can be corrected by measuring the velocity of Meinel OH bands in the sky spectrum.
  • A 2% pixel-to-pixel flux calibration error is expected based on comparison with Hubble images of M 57.
  • Astrometric calibration is limited to ~1” accuracy due to uncorrected optical distortions, with current reliance on the USNO-B1 catalog.
  • Future data releases will improve calibration via 3D phase correction, better flat-fielding, and internal phase analysis to enhance wavelength and flux accuracy.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.