Skip to main content
QUICK REVIEW

[Paper Review] CCAT-prime: Characterization of the First 280 GHz MKID Array for Prime-Cam

Steve K. Choi, Cody J. Duell|arXiv (Cornell University)|Nov 1, 2021
Superconducting and THz Device TechnologyPhysics and Astronomy16 references3 citations
TL;DR

This paper presents the laboratory characterization of the first 280 GHz polarimetric MKID array for Prime-Cam on the CCAT-prime telescope, demonstrating negligible resonator frequency shifts (<10−4 fractional change) after re-assembly and showing that magnetic shielding improves MKID quality factors by ~1.4×, enabling high-sensitivity submillimeter observations of the cosmic microwave background and epoch of reionization.

ABSTRACT

The Prime-Cam receiver on the Fred Young Submillimeter Telescope for the CCAT-prime project aims to address important astrophysical and cosmological questions with sensitive broadband, polarimetric, and spectroscopic measurements. The primary frequency bands in development include 280, 350, and 850 GHz for the polarization-sensitive broadband channels and 210--420 GHz for the spectrometers. Microwave kinetic inductance detectors (MKIDs) are a natural choice of detector technology for the simplicity in multiplexed readout needed for large format arrays at these high frequencies. We present here the initial lab characterization of the feedhorn-coupled 280 GHz polarimetric MKID array, and outline the plans for the subsequent MKID arrays and the development of the testbed to characterize them.

Motivation & Objective

  • To develop and characterize a high-frequency, polarimetric MKID array for submillimeter astronomy at 280 GHz.
  • To ensure mechanical and thermal stability of the detector package by testing resonator frequency repeatability after re-assembly.
  • To evaluate the impact of magnetic shielding on MKID quality factors and resonator performance.
  • To establish a testbed and methodology for future MKID array fabrication and calibration for Prime-Cam.
  • To support the broader scientific goals of CCAT-prime, including cosmological measurements and studies of the epoch of reionization.

Proposed method

  • Fabricated a 3,456-pixel MKID array on a 150 mm TiN/Ti/TiN trilayer wafer using hexagonal close-packed layout with six RF feedlines.
  • Coupled the array to spline-profiled aluminum feedhorns milled at ASU, aligned via precision dowel pins and pogo pins to minimize mechanical stress.
  • Conducted low-temperature characterization at 100 mK in a Bluefors dilution refrigerator using ROACH-2 readout and IF electronics from ASU.
  • Measured S21 transmission to assess resonator response and quality factors (Qi), comparing data with and without external magnetic shielding.
  • Performed repeated re-assembly tests to quantify frequency shifts (∆f0/f0) and evaluated the stability of resonator frequencies.
  • Planned use of LED mapper trimming to correct frequency offsets post-fabrication, with calibration of position-to-frequency mapping.

Experimental results

Research questions

  • RQ1To what extent do mechanical re-assembly procedures induce measurable shifts in MKID resonator center frequencies?
  • RQ2How effective is Mu-metal magnetic shielding in improving MKID quality factors at 280 GHz?
  • RQ3Can the frequency stability of MKID arrays be maintained well enough to support high-throughput multiplexed readout in a cryogenic environment?
  • RQ4What is the impact of ambient magnetic fields on superconducting transition and quasiparticle density in MKID films?
  • RQ5How scalable is the current packaging and calibration approach for future large-format MKID arrays in Prime-Cam?

Key findings

  • Re-assembly of the 280 GHz MKID array package induced a mean fractional resonator frequency shift of −9 ± 8 × 10−5, with a standard deviation of 8 × 10−5, indicating negligible frequency instability.
  • The scatter in resonator frequency spacing due to re-assembly was 5–10× smaller than the scatter introduced by the LED mapper trimming process, which itself reduces fractional spacing to 3.5 × 10−4.
  • Magnetic shielding with a 1.5 mm thick Mu-metal cylinder increased the quality factor (Qi) by a factor of ~1.4, with no significant resonator frequency shift (∆f0/f0 = 4 ± 1 × 10−5).
  • The measured shielding factor for static fields was ~20 at the array location, and simulations suggest a nominal shielding factor of ~100 is achievable at the array plane.
  • The testbed and calibration procedures, including LED mapper trimming, are validated and ready for deployment on the first 280 GHz MKID array.
  • Two additional 280 GHz MKID arrays are being fabricated at NIST to complete one Prime-Cam instrument module, with plans to explore aluminum superconductors and silicon-platelet feedhorns.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.