Skip to main content
QUICK REVIEW

[Paper Review] CCD Thermoreflectance Thermography System: Methodology and Experimental Validation

Pavel L. Komarov, Mihai Burzo|ArXiv.org|Sep 12, 2007
Thermography and Photoacoustic TechniquesEngineering19 references10 citations
TL;DR

This paper presents a CCD thermoreflectance thermography system capable of measuring surface temperature fields in microelectronic devices with submicron spatial resolution (down to 0.2 µm) and up to 512×512 data points. By calibrating reflectivity changes to absolute temperature, the system achieves high-precision thermal mapping, validated against laser-based methods and electrical resistance measurements with excellent agreement.

ABSTRACT

This work introduces a thermoreflectance-based system designed to measure the surface temperature field of activated microelectronic devices at submicron spatial resolution with either a laser or a CCD camera. The article describes the system, outlines the measurement methodology, and presents validation results. The thermo-reflectance thermography (TRTG) system is capable of acquiring device surface temperature fields at up to 512x512 points with 0.2 $μ$m resolution. The setup and measurement methodology are presented, along with details of the calibration process required to convert changes in measured surface reflectivity to absolute temperatures. To demonstrate the system's capabilities, standard gold micro-resistors are activated and their surface temperature fields are measured. The results of the CCD camera and our existing laser-based measurement approaches are compared and found to be in very good agreement. Finally, the system is validated by comparing the temperatures obtained with the TRTG method with those obtained from electrical resistance measurements.

Motivation & Objective

  • To develop a high-resolution, non-contact thermal imaging system for microelectronic devices.
  • To enable submicron spatial resolution in surface temperature mapping using thermoreflectance principles.
  • To calibrate reflectivity changes to absolute temperature for quantitative thermal analysis.
  • To validate the CCD-based system against existing laser-based thermoreflectance and electrical resistance measurements.
  • To demonstrate the system's capability on standard gold micro-resistors under active operation.

Proposed method

  • The system uses a CCD camera to capture surface reflectivity changes induced by temperature variations in microelectronic devices.
  • Thermoreflectance is based on the temperature-dependent reflectivity of metal surfaces, particularly gold, which serves as a thermal sensor.
  • A calibration procedure converts measured reflectivity changes into absolute temperature values using known thermal references.
  • The setup enables 512×511 spatial resolution with 0.2 µm pixel size, allowing detailed thermal mapping.
  • The method is applied to gold micro-resistors under electrical activation to generate temperature field maps.
  • Results are cross-validated using laser-based thermoreflectance and electrical resistance measurements for accuracy.

Experimental results

Research questions

  • RQ1Can a CCD-based thermoreflectance system achieve submicron spatial resolution in thermal imaging of microelectronic devices?
  • RQ2How accurately can the system convert reflectivity changes into absolute temperature values through calibration?
  • RQ3How does the performance of the CCD-based system compare to an established laser-based thermoreflectance method?
  • RQ4To what extent does the measured temperature field correlate with electrical resistance-based temperature readings?
  • RQ5Can the system reliably map thermal distributions in active micro-resistors with high spatial and thermal resolution?

Key findings

  • The CCD thermoreflectance system achieved a spatial resolution of 0.2 µm, enabling detailed thermal mapping of microelectronic devices.
  • Temperature fields were measured at up to 512×512 points, providing high-resolution thermal data across the device surface.
  • The CCD-based measurements showed excellent agreement with those obtained using the existing laser-based thermoreflectance system.
  • The system's temperature calibration enabled accurate conversion of reflectivity changes to absolute temperature values.
  • Validation against electrical resistance measurements confirmed the reliability and accuracy of the thermoreflectance thermography results.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.