[Paper Review] CiT-Net: Convolutional Neural Networks Hand in Hand with Vision Transformers for Medical Image Segmentation
This paper proposes CiT-Net, a hybrid CNN-Transformer architecture for medical image segmentation that integrates dynamic deformable convolution in the CNN branch and a shifted-window adaptive complementary attention module in the Transformer branch. The model achieves state-of-the-art performance with lower parameters and FLOPs than SOTA methods, even without pre-training, outperforming models like Swin-Unet and TransUNet on ISIC2018 and LiTS-Liver datasets.
The hybrid architecture of convolutional neural networks (CNNs) and Transformer are very popular for medical image segmentation. However, it suffers from two challenges. First, although a CNNs branch can capture the local image features using vanilla convolution, it cannot achieve adaptive feature learning. Second, although a Transformer branch can capture the global features, it ignores the channel and cross-dimensional self-attention, resulting in a low segmentation accuracy on complex-content images. To address these challenges, we propose a novel hybrid architecture of convolutional neural networks hand in hand with vision Transformers (CiT-Net) for medical image segmentation. Our network has two advantages. First, we design a dynamic deformable convolution and apply it to the CNNs branch, which overcomes the weak feature extraction ability due to fixed-size convolution kernels and the stiff design of sharing kernel parameters among different inputs. Second, we design a shifted-window adaptive complementary attention module and a compact convolutional projection. We apply them to the Transformer branch to learn the cross-dimensional long-term dependency for medical images. Experimental results show that our CiT-Net provides better medical image segmentation results than popular SOTA methods. Besides, our CiT-Net requires lower parameters and less computational costs and does not rely on pre-training. The code is publicly available at https://github.com/SR0920/CiT-Net.
Motivation & Objective
- To address the limitations of fixed receptive fields and parameter sharing in standard CNNs for medical image segmentation.
- To overcome the lack of channel and cross-dimensional attention in standard Transformers, which reduces performance on complex medical images.
- To reduce model complexity and eliminate dependency on pre-training by replacing MLPs with a lightweight perceptron module.
- To achieve high segmentation accuracy with lower computational cost and fewer parameters than existing hybrid CNN-Transformer models.
- To develop a robust, efficient, and generalizable architecture for medical image segmentation that preserves both local and global features.
Proposed method
- Introduces Dynamic Deformable Convolution (DDConv) in the CNN branch to enable adaptive spatial feature extraction by learning kernel offsets and avoiding fixed kernel constraints.
- Proposes a Shifted-Window Adaptive Complementary Attention Module ((S)W-ACAM) in the Transformer branch to model cross-dimensional dependencies between spatial and channel features through adaptive attention.
- Employs a Lightweight Perceptron Module (LPM) to replace the standard MLP in the Transformer, significantly reducing model parameters and computational cost.
- Designs a dual-branch architecture where the CNN and Transformer branches process features in parallel, fusing local and global representations effectively.
- Uses a compact convolutional projection to maintain efficiency while enabling long-range dependency modeling in the Transformer branch.
- Trains the model end-to-end without pre-training, reducing overfitting risks and improving generalization on limited medical datasets.
Experimental results
Research questions
- RQ1Can dynamic deformable convolution improve local feature representation in medical image segmentation compared to standard CNNs?
- RQ2Does incorporating cross-dimensional attention in the Transformer branch enhance segmentation accuracy on complex medical images?
- RQ3Can a lightweight perceptron module effectively replace the standard MLP in Transformers to reduce model size and computational cost without sacrificing performance?
- RQ4How does the proposed hybrid architecture compare to SOTA methods in terms of segmentation accuracy, parameter count, and FLOPs, especially without pre-training?
- RQ5To what extent does the integration of adaptive attention and dynamic convolution improve the preservation of local and global features in medical images?
Key findings
- CiT-Net-B achieves a Dice score of 90.88% on the ISIC2018 dataset, outperforming Swin-Unet, TransUNet, and CvT by 1.20%, 1.03%, and 1.01% respectively, even without pre-training.
- CiT-Net-T achieves the best Dice score of 90.72% on ISIC2018 with only 11.58M parameters and 4.53 GFLOPs, making it the most efficient SOTA model.
- On the LiTS-Liver dataset, CiT-Net-B achieves superior performance across all five metrics (DI, VOE, RVD, ASD, RMSD), demonstrating strong generalization and robustness.
- Ablation studies confirm that combining DDConv and (S)W-ACAM yields the best performance, with a 1.2% Dice improvement over baseline when both are used.
- The LPM reduces model parameters to 9.67M in the best configuration, significantly lowering computational cost while maintaining high accuracy.
- CiT-Net outperforms BAT, CvT, and CrossForm in Dice score by 1.02%, 3.00%, and 3.79% respectively on ISIC2018, despite having fewer parameters and less FLOPs.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.