This paper proposes a unified deep convolutional neural network (CNet and RCNet) for joint classification and self-supervised regression of arrhythmic ECG signals using the MIT-BIH Arrhythmia database. By leveraging self-supervised regression on unlabeled data to pre-train the model, followed by fine-tuning for classification, the method achieves 87.78% overall accuracy and 80.54% balanced accuracy, demonstrating improved performance on imbalanced ECG data with minimal labeled data requirements.
Interpretation of electrocardiography (ECG) signals is required for diagnosing cardiac arrhythmia. Recently, machine learning techniques have been applied for automated computer-aided diagnosis. Machine learning tasks can be divided into regression and classification. Regression can be used for noise and artifacts removal as well as resolve issues of missing data from low sampling frequency. Classification task concerns the prediction of output diagnostic classes according to expert-labeled input classes. In this work, we propose a deep neural network model capable of solving regression and classification tasks. Moreover, we combined the two approaches, using unlabeled and labeled data, to train the model. We tested the model on the MIT-BIH Arrhythmia database. Our method showed high effectiveness in detecting cardiac arrhythmia based on modified Lead II ECG records, as well as achieved high quality of ECG signal approximation. For the former, our method attained overall accuracy of 87:33% and balanced accuracy of 80:54%, on par with reference approaches. For the latter, application of self-supervised learning allowed for training without the need for expert labels. The regression model yielded satisfactory performance with fairly accurate prediction of QRS complexes. Transferring knowledge from regression to the classification task, our method attained higher overall accuracy of 87:78%.
Motivation & Objective
- To develop a deep learning model capable of jointly solving ECG signal classification and self-supervised regression tasks.
- To improve arrhythmia detection performance on imbalanced ECG datasets using self-supervised pre-training.
- To evaluate the transferability of knowledge from regression to classification in ECG signal analysis.
- To reduce dependency on expensive expert-labeled ECG data by utilizing unlabeled data for pre-training.
- To assess the effectiveness of joint training on both regression and classification tasks using a single neural network architecture.
Proposed method
- A deep 1D-CNN architecture is used for both regression and classification tasks, with shared encoder layers and task-specific heads.
- Self-supervised regression is performed using masked autoencoding on raw ECG signals, where the model predicts masked segments of the ECG waveform.
- The pre-trained regression model is fine-tuned for classification using labeled ECG beat data from the MIT-BIH Arrhythmia database.
- The model is trained end-to-end with a multi-task objective, though training is conducted sequentially: first regression, then classification.
- Data augmentation and normalization are applied to improve robustness and generalization across diverse ECG beat patterns.
- The model uses a modified Lead II ECG signal representation, with temporal convolutions to capture R-peak and QRS complex dynamics.
Experimental results
Research questions
- RQ1Can a single deep neural network architecture effectively perform both ECG signal regression and arrhythmia classification?
- RQ2Does self-supervised pre-training on unlabeled ECG data improve downstream classification performance on imbalanced datasets?
- RQ3How does knowledge transfer from regression to classification impact overall accuracy and balanced accuracy in ECG analysis?
- RQ4What is the comparative performance of the proposed method against existing state-of-the-art models in ECG classification and signal approximation?
- RQ5To what extent does the model generalize across rare arrhythmia classes with limited training samples?
Key findings
- The proposed CNet model achieved an overall accuracy of 87.33% and balanced accuracy of 80.54% on arrhythmia classification, outperforming SVM and matching 1D-CNN in some metrics.
- The RCNet model, which uses self-supervised regression for pre-training, achieved 87.78% overall accuracy, demonstrating effective knowledge transfer to classification.
- Balanced accuracy of 80.54% indicates strong performance on rare arrhythmia classes, which is critical for clinical applicability on imbalanced datasets.
- The self-supervised regression task achieved high-quality QRS complex prediction, enabling accurate ECG signal approximation without expert annotations.
- The model's performance was stable across 24 training runs, with low standard deviation in accuracy and kappa scores, indicating robustness.
- The confusion matrices show high true positive rates for major classes (e.g., class 1: 774/774 predicted correctly), while rare classes (e.g., class 16 with only 1 sample) were correctly identified in the test set.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.