Skip to main content
QUICK REVIEW

[Paper Review] Classification of COVID-19 in CT Scans using Multi-Source Transfer Learning

Alejandro Martínez|arXiv (Cornell University)|Sep 22, 2020
COVID-19 diagnosis using AIMedicine19 references7 citations
TL;DR

This paper proposes a multi-source transfer learning (MSTL) framework that improves COVID-19 detection in CT scans by fine-tuning ImageNet-pretrained models on an intermediate lung CT dataset before adapting to a small COVID-19 dataset. The approach achieves a 0.897 recall score—9.3% higher than baseline—using an unsupervised label creation method for enhanced performance on deep residual networks.

ABSTRACT

Since December of 2019, novel coronavirus disease COVID-19 has spread around the world infecting millions of people and upending the global economy. One of the driving reasons behind its high rate of infection is due to the unreliability and lack of RT-PCR testing. At times the turnaround results span as long as a couple of days, only to yield a roughly 70% sensitivity rate. As an alternative, recent research has investigated the use of Computer Vision with Convolutional Neural Networks (CNNs) for the classification of COVID-19 from CT scans. Due to an inherent lack of available COVID-19 CT data, these research efforts have been forced to leverage the use of Transfer Learning. This commonly employed Deep Learning technique has shown to improve model performance on tasks with relatively small amounts of data, as long as the Source feature space somewhat resembles the Target feature space. Unfortunately, a lack of similarity is often encountered in the classification of medical images as publicly available Source datasets usually lack the visual features found in medical images. In this study, we propose the use of Multi-Source Transfer Learning (MSTL) to improve upon traditional Transfer Learning for the classification of COVID-19 from CT scans. With our multi-source fine-tuning approach, our models outperformed baseline models fine-tuned with ImageNet. We additionally, propose an unsupervised label creation process, which enhances the performance of our Deep Residual Networks. Our best performing model was able to achieve an accuracy of 0.893 and a Recall score of 0.897, outperforming its baseline Recall score by 9.3%.

Motivation & Objective

  • Address the challenge of limited labeled COVID-19 CT scan data for training robust deep learning models.
  • Overcome the domain shift between ImageNet and medical CT images by introducing an intermediate transition dataset of lung CT scans.
  • Improve model sensitivity in detecting COVID-19 by reducing false negatives, a critical concern in infectious disease screening.
  • Develop an unsupervised label creation process to enhance performance on deep residual networks without requiring manual annotations.
  • Demonstrate that multi-source fine-tuning outperforms standard transfer learning using ImageNet alone.

Proposed method

  • Pretrain multiple deep CNNs (e.g., DenseNet169, ResNet101V2) on the ImageNet ILSVRC dataset as the source domain.
  • Fine-tune the pretrained models on a transition dataset of 22,238 lung CT slices from the SPIE-AAPM Lung CT Challenge to adapt to medical imaging features.
  • Further fine-tune the models on a target dataset of 349 COVID-19 and 397 normal CT scans from UCSD for classification.
  • Implement an unsupervised label creation process that assigns soft labels based on model confidence, improving generalization in low-data regimes.
  • Apply two labeling strategies—hard labels (binary) and soft labels (class probabilities)—to evaluate their impact on model performance.
  • Use transfer learning with multiple source domains: ImageNet (general images), lung CT (intermediate medical domain), and the final target (COVID-19 vs. normal CT).

Experimental results

Research questions

  • RQ1Can multi-source transfer learning improve the performance of deep learning models in classifying COVID-19 from CT scans compared to standard ImageNet-based transfer learning?
  • RQ2How does introducing an intermediate transition dataset of lung CT scans affect model generalization and sensitivity to COVID-19?
  • RQ3To what extent does an unsupervised label creation method enhance the performance of deep residual networks in low-data medical imaging scenarios?
  • RQ4How do different labeling strategies (hard vs. soft) affect model performance, particularly in terms of recall and false negative rates?
  • RQ5What is the impact of model architecture complexity (e.g., ResNet vs. DenseNet) on performance under varying labeling and fine-tuning strategies?

Key findings

  • The best-performing model, ResNet101V2 with soft labels, achieved a recall score of 0.897, representing a 9.3% improvement over the baseline model.
  • The ResNet101V2 model with soft labels had 3 fewer false negatives than the DenseNet169 model with hard labels, making it more suitable for clinical deployment where false negatives are highly detrimental.
  • DenseNets outperformed ResNets under the hard labeling strategy, while ResNets outperformed DenseNets under the soft labeling strategy, indicating architecture-specific sensitivity to labeling methods.
  • The multi-source transfer learning approach significantly reduced the domain gap between ImageNet and medical CT images, leading to improved feature learning and classification accuracy.
  • The unsupervised label creation process enhanced model performance, particularly for deep residual networks, by providing more nuanced supervision during fine-tuning.
  • The study demonstrated that transfer learning can be substantially improved by incorporating a domain-relevant intermediate dataset, especially when target data is scarce.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.