Skip to main content
QUICK REVIEW

[Paper Review] Classification of Upper Arm Movements from EEG signals using Machine Learning with ICA Analysis

Pranali Kokate, Sidharth Pancholi|arXiv (Cornell University)|Jul 18, 2021
EEG and Brain-Computer InterfacesNeuroscience42 references16 citations
TL;DR

This paper proposes a machine learning framework combining Independent Component Analysis (ICA) for artifact removal and a Multi-layer Perceptron Neural Network (MLP-NN) with handcrafted time- and frequency-domain features to classify left/right upper arm movements from EEG signals. The method achieved 96.02% accuracy across all subjects and 94.72% intra-subject accuracy, outperforming deep learning baselines in training efficiency and classification performance.

ABSTRACT

The Brain-Computer Interface system is a profoundly developing area of experimentation for Motor activities which plays vital role in decoding cognitive activities. Classification of Cognitive-Motor Imagery activities from EEG signals is a critical task. Hence proposed a unique algorithm for classifying left/right-hand movements by utilizing Multi-layer Perceptron Neural Network. Handcrafted statistical Time domain and Power spectral density frequency domain features were extracted and obtained a combined accuracy of 96.02%. Results were compared with the deep learning framework. In addition to accuracy, Precision, F1-Score, and recall was considered as the performance metrics. The intervention of unwanted signals contaminates the EEG signals which influence the performance of the algorithm. Therefore, a novel approach was approached to remove the artifacts using Independent Components Analysis which boosted the performance. Following the selection of appropriate feature vectors that provided acceptable accuracy. The same method was used on all nine subjects. As a result, intra-subject accuracy was obtained for 9 subjects 94.72%. The results show that the proposed approach would be useful to classify the upper limb movements accurately.

Motivation & Objective

  • To develop a robust EEG-based brain-computer interface (BCI) for classifying left and right upper arm motor imagery movements.
  • To address the challenge of EEG signal contamination by physiological and environmental artifacts that degrade classification performance.
  • To improve classification accuracy by integrating handcrafted time-domain and frequency-domain features with a machine learning classifier.
  • To compare the proposed method’s performance with deep learning architectures in terms of accuracy, training time, and model efficiency.
  • To validate the model using an intra-subject cross-validation strategy across nine subjects for reliable generalization.

Proposed method

  • Applied Independent Component Analysis (ICA) to decompose and remove artifacts from raw EEG signals, enhancing signal quality before feature extraction.
  • Extracted handcrafted statistical features from the pre-processed EEG signals, including mean, variance, skewness, kurtosis, area under the curve, and power spectral density (PSD).
  • Combined time-domain and frequency-domain features into a single feature vector to leverage complementary information for improved classification.
  • Trained a Multi-layer Perceptron Neural Network (MLP-NN) on the combined feature vectors for binary and multi-class classification of motor imagery tasks.
  • Used a 90-10 train-validation split with batch size 128, applied data normalization, and employed model checkpointing to save the best-performing model.
  • Compared the proposed method with a deep learning architecture (CNN-LSTM) using the same dataset, evaluating both on accuracy, precision, recall, and F1-score.

Experimental results

Research questions

  • RQ1Can ICA effectively reduce artifacts in EEG signals to improve the performance of motor imagery classification?
  • RQ2Does combining time-domain and frequency-domain features enhance classification accuracy for upper limb movement tasks?
  • RQ3How does the proposed MLP-NN-based method compare to deep learning models in terms of accuracy and training efficiency?
  • RQ4What is the intra-subject classification accuracy when applying the proposed method across multiple subjects?
  • RQ5Can handcrafted features with a lightweight MLP-NN outperform complex deep learning models in EEG-based BCI systems?

Key findings

  • The proposed method achieved a combined accuracy of 96.02% when classifying left and right hand motor imagery movements using both time- and frequency-domain features.
  • Intra-subject classification accuracy reached 94.72% across all nine subjects, demonstrating strong individual subject performance and generalization.
  • The ICA-based artifact removal step significantly improved signal quality and contributed to the overall performance boost, confirming its critical role in preprocessing.
  • The MLP-NN model outperformed the deep learning baseline (CNN-LSTM), achieving 95.41% accuracy compared to the proposed method’s 96.02%, while training faster and requiring less computational time.
  • Precision, recall, and F1-score were consistently high across all classes, with F1-scores ranging from 0.80 to 0.89, indicating robust and balanced classification performance.
  • The study confirmed that both time-domain and frequency-domain features are essential, as combining them yielded superior results compared to using either domain alone.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.