ClinConsensus introduces a 2,500-case Chinese medical benchmark across 36 specialties and 12 task types, with a rubric-based CACS@k evaluation and a dual-judge framework to assess LLM usability in real-world clinical workflows.
Large language models (LLMs) are increasingly applied to health management, showing promise across disease prevention, clinical decision-making, and long-term care. However, existing medical benchmarks remain largely static and task-isolated, failing to capture the openness, longitudinal structure, and safety-critical complexity of real-world clinical workflows. We introduce ClinConsensus, a Chinese medical benchmark curated, validated, and quality-controlled by clinical experts. ClinConsensus comprises 2500 open-ended cases spanning the full continuum of care--from prevention and intervention to long-term follow-up--covering 36 medical specialties, 12 common clinical task types, and progressively increasing levels of complexity. To enable reliable evaluation of such complex scenarios, we adopt a rubric-based grading protocol and propose the Clinically Applicable Consistency Score (CACS@k). We further introduce a dual-judge evaluation framework, combining a high-capability LLM-as-judge with a distilled, locally deployable judge model trained via supervised fine-tuning, enabling scalable and reproducible evaluation aligned with physician judgment. Using ClinConsensus, we conduct a comprehensive assessment of several leading LLMs and reveal substantial heterogeneity across task themes, care stages, and medical specialties. While top-performing models achieve comparable overall scores, they differ markedly in reasoning, evidence use, and longitudinal follow-up capabilities, and clinically actionable treatment planning remains a key bottleneck. We release ClinConsensus as an extensible benchmark to support the development and evaluation of medical LLMs that are robust, clinically grounded, and ready for real-world deployment.
Motivation & Objective
- Propose a clinically grounded benchmark for evaluating medical LLMs in prevention, treatment, and long-term management within Chinese clinical practice.
- Ensure cases are open-ended, multi-task, and progressively complex to reflect real-world workflows.
- Establish a scalable evaluation framework using rubric-based judgments and a threshold-calibrated usability metric (CACS@k).
- Validate evaluation reliability with a dual-judge setup (LLM-as-judge plus a distilled trained judge).
Proposed method
- Curate 2,500 expert-annotated cases covering 36 specialties and 12 task types across prevention, treatment, and long-term management.
- Annotate each case with 30 binary evaluation criteria and 73 consensus-level criteria for rubric construction.
- Use a two-stage quality control pipeline: difficulty-based filtering against 3 leading LLMs and senior clinician auditing.
- Employ a rubric-based evaluation where each case response is judged on 30 binary criteria to produce rubric decisions.
- Adopt two graders: (i) an LLM-as-judge (e.g., GPT-4.1/5.x) and (ii) a distilled trained judge (8B) trained via supervised fine-tuning on 33.7k rubric-level instances.
- Define and calibrate CACS@k as a threshold-based, truncated aggregation of rubric hits with k empirically set to 7 using expert responses.

Experimental results
Research questions
- RQ1How do leading Chinese medical LLMs perform on a large-scale, open-ended, clinically validated benchmark across diverse specialties and tasks?
- RQ2What is the gap between rubric accuracy and clinically usable performance (CACS@k) across complexity levels and care stages?
- RQ3How stable are model rankings across different automated judges (LLM-as-judge vs. distilled judge) for ClinConsensus evaluations?
- RQ4What are the main bottlenecks in reasoning, evidence use, and longitudinal follow-up across specialties?
- RQ5Can ClinConsensus reveal safety-critical weaknesses not captured by traditional benchmarks?
Key findings
- GPT-5.2 leads with a CACS@7 of 34.7%, with Qwen3-Max at 33.3% and Qwen-Plus at 31.4%.
- Across models, rubric accuracy overestimates usability by about 12.5–15.5 percentage points, indicating a usability gap.
- Performance is higher on reasoning-heavy tasks like patient education and follow-up, but drops on extraction and documentation tasks (e.g., medical NER 26.0%, clinical summarization 28.1%).
- Specialty-level results show high variance; GPT-5.2 is strong in many areas but weak in Organ Transplantation and Plastic Surgery, while domestic models excel in resource-intensive Chinese contexts (e.g., Anesthesiology, Critical Care).
- Case complexity degrades performance (L1 > L2 > L3), with a notable drop for weaker models; prevention stages outperform treatment in general.
- Bottlenecks identified in clinical reasoning for personalized treatment planning, with scores in this area around 7.68% for top models.