CMUNeXt is a lightweight, fully convolutional U-shaped medical image segmentation network that uses large-kernel depthwise convolutions with inverted bottlenecks and a Skip-Fusion block to efficiently capture global context and fuse encoder-decoder features, achieving strong accuracy with low compute and fast inference on ultrasound datasets.
The U-shaped architecture has emerged as a crucial paradigm in the design of medical image segmentation networks. However, due to the inherent local limitations of convolution, a fully convolutional segmentation network with U-shaped architecture struggles to effectively extract global context information, which is vital for the precise localization of lesions. While hybrid architectures combining CNNs and Transformers can address these issues, their application in real medical scenarios is limited due to the computational resource constraints imposed by the environment and edge devices. In addition, the convolutional inductive bias in lightweight networks adeptly fits the scarce medical data, which is lacking in the Transformer based network. In order to extract global context information while taking advantage of the inductive bias, we propose CMUNeXt, an efficient fully convolutional lightweight medical image segmentation network, which enables fast and accurate auxiliary diagnosis in real scene scenarios. CMUNeXt leverages large kernel and inverted bottleneck design to thoroughly mix distant spatial and location information, efficiently extracting global context information. We also introduce the Skip-Fusion block, designed to enable smooth skip-connections and ensure ample feature fusion. Experimental results on multiple medical image datasets demonstrate that CMUNeXt outperforms existing heavyweight and lightweight medical image segmentation networks in terms of segmentation performance, while offering a faster inference speed, lighter weights, and a reduced computational cost. The code is available at https://github.com/FengheTan9/CMUNeXt.
Motivation & Objective
- Motivate the need for global context extraction in lightweight medical segmentation under edge/clinical constraints.
- Propose a fully convolutional CMUNeXt architecture with large-kernel blocks and inverted bottleneck design for efficient global information mixing.
- Introduce Skip-Fusion blocks to enable smooth, effective encoder-decoder feature fusion.
- Demonstrate that CMUNeXt achieves favorable accuracy vs. computation on ultrasound breast and thyroid datasets and provide open-source code and benchmarks.
Proposed method
- Introduce CMUNeXt block: depthwise large-kernel convolution followed by two inverted bottleneck pointwise convolutions with GELU and BatchNorm in a residual setup.
- Replace standard skip connections with Skip-Fusion blocks: grouped convolution with two inverted bottleneck pointwise convolutions for encoder-decoder feature fusion.
- Use a five-level U-shaped encoder-decoder with a stem, Down-Sample via max pooling, and Bilinear upsampling in the decoder.
- Train with a combined BCE and Dice loss and standard SGD optimization on resized 256x256 images with data augmentations.
- Provide three CMUNeXt variants (S, L, and baseline) with different channel configurations and kernel settings to balance accuracy and compute.
Experimental results
Research questions
- RQ1Can a fully convolutional lightweight network with large kernels match or surpass Transformer-based and heavyweight CNN-based medical segmentation models on ultrasound data?
- RQ2Does the proposed CMUNeXt block enable effective global context coupling with minimal parameters in a U-Net like architecture?
- RQ3Do Skip-Fusion blocks improve encoder-decoder feature fusion and overall segmentation performance under edge-device constraints?
- RQ4How do CMUNeXt variants trade off accuracy, parameters, FLOPs, and FPS across different ultrasound datasets?
Key findings
- CMUNeXt achieves competitive to state-of-the-art segmentation performance while using fewer parameters and lower computation than heavyweight baselines.
- CMUNeXt-S yields fast inference (high FPS) with competitive IoU and F1 scores on ultrasound datasets.
- CMUNeXt-L delivers strong performance with reduced parameters and FLOPs compared to CMU-Net and TransUNet, while increasing FPS.
- Ablation shows that replacing conventional conv with CMUNeXt blocks and adding Skip-Fusion blocks progressively improves segmentation accuracy and maintains efficiency.
- Large-kernel convolution with preserved inductive bias effectively captures global context in medical images, aiding precise lesion localization.
- Training stability is improved and convergence is faster for CMUNeXt compared to U-Net and UNeXt on multiple datasets.