[Paper Review] Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control
This paper presents a multi-method validation of HPK 3.1 LGAD sensors for high-luminosity LHC timing detectors, demonstrating that beta source measurements accurately reproduce proton beam responses and that probe station CV measurements predict sensor operating voltage with high precision. The key contribution is establishing a scalable, high-volume quality control protocol based on probe station data, confirming sufficient gain uniformity across full-sized sensors for CMS and ATLAS.
The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. We further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.
Motivation & Objective
- To validate that beta source measurements accurately reproduce the response of HPK 3.1 LGADs to high-energy protons, enabling scalable sensor characterization.
- To establish a reliable correlation between probe station capacitance-voltage (CV) measurements and actual sensor operating parameters.
- To assess the uniformity of the gain implant across full-sized LGAD sensors to ensure consistent performance under a single bias voltage.
- To develop a high-volume, non-destructive quality control protocol for production of full-sized LGAD sensors for CMS and ATLAS timing detectors.
Proposed method
- Conducted test beam measurements using 120 GeV protons at Fermilab Test Beam Facility to characterize LGAD response in terms of charge collection, time resolution, and efficiency.
- Performed beta source characterization using a 106Ru source to simulate particle responses in a high-throughput, non-beamtime-limited setup.
- Used a 16-channel readout board at Fermilab to enable full-sensor mapping and pad-level analysis of LGAD prototypes.
- Performed probe station measurements of capacitance-voltage (CV) characteristics to extract gain layer depletion voltage and correlate it with operational bias voltage.
- Compared results from proton beam, beta source, and probe station measurements to validate cross-method consistency and establish predictive relationships.
- Analyzed spatial uniformity of gain implant across 22 sensors and full wafers, focusing on variation within 2×4 cm² sensor areas.
Experimental results
Research questions
- RQ1Can beta source measurements accurately reproduce the charge collection and time resolution response of HPK 3.1 LGADs as measured in proton test beams?
- RQ2Is there a reliable, quantitative relationship between probe station CV measurements and the operational bias voltage required for full gain in LGAD sensors?
- RQ3What is the level of gain uniformity across the HPK 3.1 LGAD wafer, and is it sufficient to support full-sized sensors operated at a single bias voltage?
- RQ4Can probe station CV measurements be used as a fast, high-volume, and reliable method for quality control during production of LGAD sensors for CMS and ATLAS?
Key findings
- Beta source measurements accurately reproduce the charge collection and time resolution response of HPK 3.1 LGADs as measured in proton test beams, validating the use of beta sources for high-throughput characterization.
- A strong linear correlation was observed between the CV transition voltage (gain layer depletion voltage) and the operating bias voltage required to achieve 20 fC of collected charge, with a few outliers.
- The variation in gain layer depletion voltage across the sensor area is limited to approximately 1% for 2×4 cm² sensor regions, ensuring all pads can be operated within a 20 V bias window.
- The uniformity of the gain implant in the HPK 3.1 batch is sufficient to produce full-sized sensors capable of achieving a time resolution of 30 ps before irradiation.
- Probe station CV measurements can reliably predict the operating voltage of each sensor, enabling fast, non-destructive, and scalable quality control during production.
- The combined use of test beam, beta source, and probe station data enables a comprehensive, high-volume quality control framework for LGAD production, reducing reliance on scarce beamtime.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.