TL;DR

This paper proposes a hybrid EHO-SVM model for automated ECG heartbeat classification, using a modified Pan-Tompkins algorithm for noise reduction, extended feature extraction for 19 ECG features, and elephant herding optimization to select optimal features and tune SVM parameters. The approach achieves 93.31% accuracy on the MIT-BIH arrhythmia database, outperforming prior methods.

ABSTRACT

Many people are currently suffering from heart diseases that can lead to untimely death. The most common heart abnormality is arrhythmia, which is simply irregular beating of the heart. A prediction system for the early intervention and prevention of heart diseases, including cardiovascular diseases (CDVs) and arrhythmia, is important. This paper introduces the classification of electrocardiogram (ECG) heartbeats into normal or abnormal. The approach is based on the combination of swarm optimization algorithms with a modified PannTompkins algorithm (MPTA) and support vector machines (SVMs). The MPTA was implemented to remove ECG noise, followed by the application of the extended features extraction algorithm (EFEA) for ECG feature extraction. Then, elephant herding optimization (EHO) was used to find a subset of ECG features from a larger feature pool that provided better classification performance than that achieved using the whole set. Finally, SVMs were used for classification. The results show that the EHOSVM approach achieved good classification results in terms of five statistical indices: accuracy, 93.31%; sensitivity, 45.49%; precision, 46.45%; F-measure, 45.48%; and specificity, 45.48%. Furthermore, the results demonstrate a clear improvement in accuracy compared to that of other methods when applied to the MITBIH arrhythmia database.

Motivation & Objective

  • To improve the accuracy of ECG-based cardiac arrhythmia classification using hybrid optimization and machine learning.
  • To address the challenge of high-dimensional ECG feature spaces by selecting the most discriminative features.
  • To enhance classification performance through staged optimization of feature selection and SVM parameter tuning.
  • To validate the model on a large, diverse dataset from the MIT-BIH arrhythmia database using robust cross-validation.
  • To provide a reliable, automated system for early detection of abnormal heartbeats to support clinical decision-making.

Proposed method

  • A modified Pan-Tompkins algorithm (MPTA) is applied to preprocess ECG signals and reduce noise.
  • An extended feature extraction algorithm (EFEA) extracts 19 morphological and temporal features from QRS complexes, P waves, and T waves.
  • Elephant Herding Optimization (EHO) is used to search for the optimal subset of features that maximizes classification accuracy.
  • Support Vector Machines (SVMs) are trained on the selected features, with EHO also optimizing SVM penalty parameters.
  • A 3-fold leave-one-out cross-validation strategy is used to ensure generalized performance evaluation.
  • The method employs staged optimization: feature selection and parameter tuning are performed separately to avoid interference between correlated variables.

Experimental results

Research questions

  • RQ1Can elephant herding optimization effectively improve ECG heartbeat classification accuracy by selecting optimal feature subsets?
  • RQ2Does staged optimization of feature selection and SVM parameter tuning outperform simultaneous optimization in ECG classification?
  • RQ3How does the EHO-SVM model compare to existing methods in terms of accuracy and robustness on the MIT-BIH arrhythmia database?
  • RQ4To what extent does the use of extended feature extraction enhance classification performance over basic feature sets?
  • RQ5Can the proposed hybrid model achieve high accuracy while maintaining computational efficiency in real-time clinical applications?

Key findings

  • The EHO-SVM model achieved 93.31% classification accuracy on the MIT-BIH arrhythmia database, outperforming previous methods such as BFPSO-SVM (76.74%) and Hermite function-based approaches (90%).
  • Sensitivity, precision, F-measure, and specificity were all approximately 45.48%, indicating balanced performance across positive and negative class predictions.
  • The convergence curves show that EHO reaches optimal accuracy within a relatively small number of iterations, indicating fast and stable convergence.
  • The staged optimization approach prevented performance degradation from simultaneous tuning of features and SVM parameters, leading to improved generalization.
  • The model demonstrated robustness across 10 patients, 16 arrhythmia types, and 24,474 ECG records, validating its scalability and reliability.
  • The results confirm that EHO is a viable and effective meta-heuristic for feature selection in ECG classification, offering a competitive alternative to PSO and GA-based methods.