[Paper Review] Comparative Analysis and Calibration of Low Cost Resistive and Capacitive Soil Moisture Sensor
This study compares low-cost resistive and capacitive soil moisture sensors through calibration against gravimetric and volumetric water content and analyzes their response to incremental water additions. The resistive sensor showed higher RMSE and greater variability, especially at higher moisture levels, while the capacitive sensor demonstrated superior stability, sensitivity, and durability due to corrosion-resistant probes, making it more suitable for long-term monitoring despite slightly lower R² values in calibration.
Soil moisture is an essential parameter in agriculture. It determines several environmental and agricultural activities such as climate change, drought prediction, irrigation, etc. Smart irrigation management requires continuous soil moisture monitoring to reduce unnecessary water usage. In recent times, the use of low-cost sensors is becoming popular among farmers for soil moisture monitoring. In this paper, a comparison of low-cost resistive and capacitive soil moisture sensors is demonstrated in two ways. One way is the calibration of the sensors in gravimetric and volumetric water content, and the other is the sensors' response analysis when different quantities of water are added to the same amount of soil. The analysis shown in this work is essential before choosing cost-effective sensors for any soil moisture monitoring platform.
Motivation & Objective
- To evaluate and compare the performance of low-cost resistive and capacitive soil moisture sensors in terms of calibration accuracy and response consistency.
- To calibrate both sensor types against gravimetric and volumetric water content (GWC and VWC) using experimental data.
- To analyze sensor response variability across repeated experiments with increasing water additions to the same soil sample.
- To assess sensor reliability, sensitivity, and longevity under repeated short-duration measurements.
- To provide practical guidance for selecting appropriate low-cost sensors for IoT-based soil moisture monitoring platforms.
Proposed method
- Calibration of both sensors using gravimetric and volumetric water content (GWC and VWC) as ground truth, with equations derived from experimental data.
- Measurement of raw sensor output (voltage) via NodeMCU microcontroller, digitized in the 1–1024 range and converted to 3.3V using Equation (1).
- Data transmission to the Thingspeak cloud platform using API keys for real-time storage and visualization.
- Conducting repeated experiments with incremental water additions (25ml, 50ml, 75ml, 100ml) to assess dynamic response and repeatability.
- Statistical analysis using R², RMSE, MAPE, and variance to compare calibration performance.
- Assessment of sensor durability by observing functional degradation after 5–6 short-duration measurements, particularly for resistive sensors.
Experimental results
Research questions
- RQ1How do the calibration results of resistive and capacitive sensors compare in terms of R², RMSE, and variance across repeated experiments?
- RQ2How do the sensors respond to incremental water additions in terms of output voltage variation and consistency?
- RQ3What is the impact of soil saturation on the reliability and sensitivity of resistive versus capacitive sensors?
- RQ4How does probe corrosion affect the long-term functionality of resistive sensors compared to capacitive sensors?
- RQ5Which sensor type is more suitable for long-term, continuous soil moisture monitoring in IoT-based agricultural systems?
Key findings
- The resistive sensor exhibited higher RMSE (0.125) and lower R² (0.87) compared to the capacitive sensor (RMSE: 0.089, R²: 0.92), indicating poorer calibration accuracy.
- The resistive sensor showed significantly higher output variance across repeated experiments, especially at higher moisture levels, indicating reduced reliability.
- The resistive sensor failed to detect moisture changes in dry soil conditions across repeated trials, while the capacitive sensor maintained consistent detection, indicating lower sensitivity in resistive sensors.
- For 25ml and 100ml water additions, the resistive sensor output was nearly identical, suggesting saturation-related response distortion, whereas the capacitive sensor showed a linear and consistent response.
- The resistive sensor probes degraded after 5–6 short-duration measurements due to corrosion, while the capacitive sensor’s polymer-coated probes remained functional, indicating superior durability.
- The capacitive sensor demonstrated better long-term suitability for continuous monitoring due to resistance to oxidation and electrolysis, despite slightly lower R² in calibration.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.