TL;DR

This study compares two versions of the Tsallis distribution—with and without thermodynamical description—in fitting transverse momentum spectra from p+p collisions at RHIC and LHC. It finds that the thermodynamically consistent version yields lower temperatures due to an additional $m_T$ term, which dominates discrepancies, especially for light particles; for heavier particles, the choice between $m_T$ and $E_T$ becomes more critical in temperature determination.

ABSTRACT

We compare two types of Tsallis distribution, i.e., with and without thermodynamical description, using the experimental data from the STAR, PHENIX, ALICE and CMS Collaborations on the rapidity and energy dependence of the transverse momentum spectra in p+p collisions. Both of them can give us the similar fitting power to the particle spectra. We show that the Tsallis distribution with thermodynamical description gives lower temperatures than the ones without it. The extra factor $m_T$ (transverse mass) in the Tsallis distribution with thermodynamical description plays an important role in the discrepancies between the two types of Tsallis distribution. But for the heavy particles, the choice to use the $m_T$ or $E_T$ (transverse energy) in the Tsallis distribution becomes more crucial.

Motivation & Objective

  • To resolve the discrepancy in fitted temperatures between two widely used Tsallis distributions in high-energy p+p collisions.
  • To investigate the role of the transverse mass $m_T$ and the power-law parameter $q$ in determining temperature differences.
  • To evaluate whether thermodynamical consistency affects the phenomenological fit quality and parameter interpretation.
  • To clarify the physical meaning of temperature parameters in Tsallis distributions used in experimental particle spectra analysis.
  • To assess the impact of particle mass on the sensitivity of temperature fits to distribution form.

Proposed method

  • Compares five Tsallis distribution variants: Type-A (no thermodynamics), Type-B (with thermodynamics), and three transient forms bridging them.
  • Applies the distributions to experimental $p_T$ spectra from STAR, PHENIX, ALICE, and CMS collaborations across multiple center-of-mass energies.
  • Uses the form $E\frac{d^3N}{dp^3} = A(1 + \frac{E_T}{nT})^{-n}$ for fitting, where $E_T = m_T - m$, with $A$, $n$, and $T$ as free parameters.
  • Performs $χ^2$/ndf minimization to assess fitting quality and extract temperature parameters $T_i$ for each distribution type.
  • Analyzes the dependence of $T_i$ on collision energy $\sqrt{s}$ and particle species (pion, kaon, proton).
  • Compares the effects of the $m_T$ term and the power $q$ by isolating their contributions through intermediate distribution forms.

Experimental results

Research questions

  • RQ1Why do Tsallis distributions with and without thermodynamical description yield significantly different temperature parameters when fitting the same $p_T$ spectra?
  • RQ2How does the inclusion of the transverse mass $m_T$ in the distribution function affect the extracted temperature?
  • RQ3What is the relative impact of the power-law parameter $q$ versus the $m_T$ term on temperature discrepancies?
  • RQ4Does the sensitivity of temperature fits to distribution form increase with particle mass?
  • RQ5Which distribution form provides a more physically consistent description of particle spectra in p+p collisions?

Key findings

  • All five Tsallis distributions—Type-A, Type-B, and three transient forms—achieve comparable fitting power, with $\chi^2$/ndf values within 1% of each other.
  • The Tsallis distribution with thermodynamical description (Type-B) yields significantly lower temperatures than the one without it (Type-A), e.g., $T_1 \approx 0.075$ GeV vs. $T_5 \approx 0.13$ GeV for pions.
  • The extra $m_T$ term in the thermodynamically consistent distribution is the primary cause of the temperature discrepancy, especially for light particles like pions.
  • For heavier particles (kaons and protons), the choice between using $m_T$ or $E_T$ in the distribution becomes more critical, with $T_5$ (Type-A) being higher than $T_3$ (transient with $m_T$) due to this effect.
  • The power $q$ in the thermodynamically consistent form increases the fitted temperature relative to similar forms without $q$-dependence, but this effect is outweighed by the $m_T$ term.
  • The temperature $T$ decreases with increasing $\sqrt{s}$ for all distributions, but the relative ordering of $T_i$ remains consistent across energies.