[Paper Review] Completion of Testing Series Double-spoke Cavity Cryomodules for ESS

Rocío Santiago Kern, C. Svanberg|arXiv (Cornell University)|Jun 20, 2023
Particle accelerators and beam dynamicsEngineering3 citations
TL;DR

This paper presents the completion of testing 13 double-spoke cavity cryomodules for the European Spallation Source (ESS), marking the first deployment of this cavity type in a real accelerator. The FREIA Laboratory at Uppsala University conducted comprehensive cryogenic, RF, and mechanical tests, identifying and resolving issues such as vacuum leaks in double-wall tubes and stepper motor failures, with all repaired modules successfully retested and accepted.

ABSTRACT

The FREIA Laboratory at Uppsala University, Sweden, has completed the evaluation of 13 double-spoke cavity cryomodules for ESS. This is the first time double-spoke cavities will be deployed in a real machine. This paper summarizes testing procedures and statistics of the results and lessons learned.

Motivation & Objective

  • To validate the performance and reliability of 13 double-spoke cavity cryomodules for the European Spallation Source (ESS) prior to installation.
  • To identify and resolve technical challenges specific to double-spoke cavity cryomodules during series testing.
  • To ensure cryomodule readiness through comprehensive cryogenic, RF, and mechanical testing under real operating conditions.
  • To provide critical feedback to the SRF community on challenges such as multipacting and fast interlock requirements in spoke cavities.
  • To demonstrate successful repair and retesting of cryomodules with identified faults, ensuring no performance degradation post-repair.

Proposed method

  • Conducted site acceptance testing at FREIA Laboratory, including cryogenic cooldown to 2 K using liquid helium and liquid nitrogen thermal shields.
  • Performed RF conditioning of fundamental power couplers (FPCs) at both room and cold temperatures to ensure stable operation.
  • Executed full RF testing of cavities at 2 K, measuring field quality, tuning range, and Lorentz force detuning (LFD) characteristics.
  • Measured static and dynamic heat loads using cold tuning systems (CTS) at target frequency positions.
  • Implemented fast interlock systems for Low-Level RF (LLRF) control and verified their response during testing.
  • Used piezoelectric actuators for active compensation of LFD, with tuning range measured up to 400 Hz per actuator, exceeding required 9 MV/m LFD.
Figure 1 : Testing schedule example for a cryomodule.
Figure 1 : Testing schedule example for a cryomodule.

Experimental results

Research questions

  • RQ1What are the primary failure modes encountered during series testing of double-spoke cavity cryomodules?
  • RQ2How do vacuum leaks in double-wall tubes and stepper motor failures impact cryomodule performance and reliability?
  • RQ3To what extent do RF and mechanical parameters degrade after repair and retesting compared to initial vertical tests?
  • RQ4How effective are piezoelectric actuators in compensating for Lorentz force detuning at 9 MV/m field levels?
  • RQ5What operational and procedural improvements are necessary for efficient, large-scale cryomodule testing in future projects?

Key findings

  • All 13 cryomodules were successfully tested after initial failures, with 5 requiring repairs and all passing retesting after component replacement.
  • Vacuum leaks in the double-wall tubes were only detected during cold testing, not during warm leak checks, highlighting the importance of cold leak testing.
  • Stepper motor failures occurred due to mechanical unresponsiveness after reaching specific positions, with root cause still under investigation.
  • The piezoelectric actuators provided a tuning range exceeding 400 Hz per actuator, which is 20% higher than the required range for 9 MV/m Lorentz force detuning.
  • No significant performance degradation was observed in cavities after repair and retesting compared to pre-assembly vertical test results.
  • The testing campaign revealed unexpected challenges such as multipacting and the critical need for fast interlocks even at low RF fields, providing key insights for future spoke cavity projects.
Figure 2 : Comparison of the FPC conditioning back-to-back with standing and travelling wave (IJCLab) and when assembled in the cryomodule (FREIA).
Figure 2 : Comparison of the FPC conditioning back-to-back with standing and travelling wave (IJCLab) and when assembled in the cryomodule (FREIA).