TL;DR

ComPair proposes a MIDEX-scale space telescope optimized for MeV gamma-ray astronomy, using a dual-detection approach that combines Compton scattering and pair production in a single instrument to achieve 20–50× better sensitivity than COMPTEL across 200 keV–500 MeV. The design leverages mature, flight-qualified technologies like Si-strip and CdZnTe-strip detectors to enable high angular and energy resolution, with demonstrated sensitivity to polarization and continuum sources.

ABSTRACT

The gamma-ray energy range from a few hundred keV to a few hundred MeV has remained largely unexplored, mainly due to the challenging nature of the measurements, since the pi- oneering, but limited, observations by COMPTEL on the Compton Gamma-Ray Observatory (1991-2000). This energy range is a transition region between thermal and nonthermal processes, and accurate measurements are critical for answering a broad range of astrophysical questions. We are developing a MIDEX-scale wide-aperture discovery mission, ComPair (Compton-Pair Production Space Telescope), to investigate the energy range from 200 keV to > 500 MeV with high energy and angular resolution and with sensitivity approaching a factor of 20-50 better than COMPTEL. This instrument will be equally capable to detect both Compton-scattering events at lower energy and pair-production events at higher energy. ComPair will build on the her- itage of successful space missions including Fermi LAT, AGILE, AMS and PAMELA, and will utilize well-developed space-qualified detector technologies including Si-strip and CdZnTe-strip detectors, heavy inorganic scintillators, and plastic scintillators.

Motivation & Objective

  • Address the long-standing gap in MeV gamma-ray astronomy, a region largely unexplored since COMPTEL due to technological limitations.
  • Overcome the challenge of detecting both Compton scattering and pair production events in a single instrument with high sensitivity.
  • Achieve a factor of 20–50 improvement in sensitivity over COMPTEL and 5–10× over EGRET in the 30–100 MeV range.
  • Enable accurate measurements of photon energy, direction, and polarization across 0.2–500 MeV using a unified, scalable instrument design.
  • Reduce systematic errors by cross-validating Compton and pair-production events in the overlapping energy range (5–100 MeV).

Proposed method

  • Utilize a multi-layer silicon-strip tracker to detect electron and positron tracks from Compton scattering and pair production.
  • Employ a calorimeter composed of CdZnTe-strip (CZT) and inorganic scintillators (e.g., CsI(Tl)) to measure deposited energy and interaction position.
  • Integrate a plastic scintillator anticoincidence detector (ACD) to suppress charged particle background from the space environment.
  • Implement separate reconstruction algorithms for Compton events (using scattered photon energy and direction) and pair-production events (using electron-positron tracks).
  • Apply energy resolution modeling based on the formula: cos Θ = (mₑc²) / (E₂ + mₑc²) × (E₁ + E₂) / E₁ for Compton scattering, where mₑc² = 511 keV.
  • Optimize the tracker by eliminating passive tungsten converters to improve point-spread function (PSF) and enable polarization measurements.

Experimental results

Research questions

  • RQ1Can a single instrument effectively detect both Compton scattering and pair production events across the 0.2–500 MeV range with high sensitivity?
  • RQ2To what extent can the combination of Compton and pair-production event reconstruction reduce systematic errors in MeV gamma-ray measurements?
  • RQ3What level of sensitivity and energy resolution can be achieved with a low-mass, high-resolution tracker and advanced scintillator calorimeter in the MeV band?
  • RQ4How well can ComPair measure photon polarization, particularly from bright sources like the Crab pulsar?
  • RQ5What is the expected sensitivity improvement over COMPTEL and EGRET in the 1–100 MeV energy range?

Key findings

  • ComPair achieves an energy resolution of 2–5% below 20 MeV and ~12% at 100 MeV, with conservative estimates based on basic energy deposition without shower shape reconstruction.
  • The instrument’s effective area reaches 200–1200 cm² above 10 MeV and 50–250 cm² below 10 MeV, enabling high sensitivity across the target energy range.
  • Point-source sensitivity improves by a factor of 20–50 compared to COMPTEL below 30 MeV and by 5–10× over EGRET in the 30–100 MeV band.
  • The instrument achieves an angular resolution of ~6° at 1 MeV, ~10° at 10 MeV, and ~1.5° at 100 MeV, significantly improving source localization.
  • ComPair can detect 20% linear polarization from the Crab pulsar with 30% accuracy in just one month of observation, assuming a measured asymmetry parameter λ = 0.2.
  • Systematic uncertainty estimates account for up to five times higher background, with sensitivity shown in Fig. 8 as a shaded region above the main ComPair curve.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.