[Paper Review] Concepts and performance of the Antares data acquisition system
The ANTARES neutrino telescope employs an 'all-data-to-shore' data acquisition system that digitizes all PMT signals and transmits them in real time to a shore-based PC farm. This enables parallel operation of multiple physics triggers—such as general muon, Galactic Centre, and gamma-ray burst triggers—achieving over 90% data-taking efficiency and purities exceeding 90% for muon triggers, significantly enhancing sensitivity to astrophysical neutrinos.
The data acquisition system of the Antares neutrino telescope is based on the unique "all-data-to-shore" concept. In this, all signals from the photo-multiplier tubes are digitised, and all digital data are sent to shore where they are processed in real time by a PC farm. This data acquisition system showed excellent stability and flexibility since the detector became operational in March 2006. The applied concept enables to operate different physics triggers to the same data in parallel, each optimized for a specific (astro)physics signal. The list of triggers includes two general purpose muon triggers, a Galactic Centre trigger, and a gamma-ray burst trigger. The performance of the data acquisition system is evaluated by its operational efficiency and the data filter capabilities. In addition, the efficiencies of the different physics triggers are quantified.
Motivation & Objective
- To develop a stable and flexible data acquisition system for the ANTARES neutrino telescope operating in deep-sea conditions.
- To enable real-time processing of all digitized PMT signals to support multiple physics triggers simultaneously.
- To maximize detection efficiency for specific astrophysical signals, such as neutrinos from the Galactic Centre and gamma-ray bursts.
- To achieve high operational efficiency and low background-induced false triggers in a high-background deep-sea environment.
- To quantify the performance of different triggers in terms of effective volume and purity.
Proposed method
- All PMT signals above a 0.3 photo-electron threshold are digitized locally using custom ARS chips in each local control module.
- Digital data are transmitted via a star-topology optical network using DWDM multiplexing and Ethernet switches to a shore-based PC farm.
- A master clock system synchronizes all local control modules to enable precise time-stamping of hits for causality-based triggering.
- Software triggers apply time-position correlations using the causality condition: |ti - tj| ≤ |xi - xj| × n/c, where n is the refractive index of seawater.
- Direction-specific triggers for the Galactic Centre use a 2D distance constraint (Rij) and Cherenkov angle (θC) to reduce combinatorics and improve efficiency.
- External triggers are synchronized with the GCN network to capture data around gamma-ray burst alerts, with buffering to include data up to one minute before the alert.
Experimental results
Research questions
- RQ1How can a data acquisition system achieve high stability and flexibility in a deep-sea neutrino telescope with high background rates?
- RQ2What is the performance of the all-data-to-shore concept in enabling parallel operation of multiple physics triggers?
- RQ3How does the Galactic Centre trigger improve detection efficiency compared to general-purpose muon triggers?
- RQ4What is the purity and effective volume of the standard and Galactic Centre triggers across different neutrino energies?
- RQ5How does real-time data filtering and buffering enhance the detection of transient astrophysical events like gamma-ray bursts?
Key findings
- The all-data-to-shore DAQ system achieved an average data-taking efficiency of over 90% since ANTARES became operational in March 2006.
- The standard muon trigger achieved a purity of better than 90%, with the 10% impurity mainly due to low-energy muons and background correlations.
- The Galactic Centre trigger significantly improves detection efficiency, with an effective volume exceeding that of the standard trigger within a 10-degree field of view.
- The trigger rate for atmospheric muons was maintained at 5–10 Hz, dominated by background, despite high PMT count rates of 60–150 kHz.
- The minimum bias trigger was used effectively for data quality monitoring, and the system supports real-time buffering for GCN alerts with up to one minute of pre-alert data.
- The system's ability to run multiple triggers in parallel on the same raw data stream enables optimized sensitivity to diverse astrophysical signals.
Read this paper