Skip to main content
QUICK REVIEW

[Paper Review] Consistent metallicity scale for cool dwarfs and giants. A benchmark test using the Hyades

Letícia Dutra-Ferreira, L. Pasquini|arXiv (Cornell University)|Sep 25, 2015
Stellar, planetary, and galactic studiesPhysics and Astronomy80 references24 citations
TL;DR

This study establishes a consistent metallicity scale for cool dwarfs and giants using the Hyades cluster as a benchmark. By combining interferometric angular diameters and 3D model-based microturbulence calibration, the authors achieve consistent metallicity results (0.18 ± 0.03 dex) across both stellar types, demonstrating that systematic differences in abundance analysis arise from methodological choices, not intrinsic composition variations.

ABSTRACT

In several instances chemical abundances of dwarf and giant stars are used simultaneously under the assumption that they share the same abundance scale. This assumption might have implications in different astrophysical contexts. We aim to ascertain a methodology capable of producing a consistent metallicity scale for giants and dwarfs. To achieve that, we analyzed giants and dwarfs in the Hyades open cluster. All these stars have archival high-resolution spectroscopic data obtained with HARPS and UVES. In addition, the giants have interferometric measurements of the angular diameters. We analyzed the sample with two methods. The first method constrains the atmospheric parameters independently from spectroscopy. For that we present a novel calibration of microturbulence based on 3D model atmospheres. The second method is the classical spectroscopic based on Fe lines. We also tested two line lists in an attempt to minimize possible non-LTE effects and to optimize the treatment of the giants. We show that it is possible to obtain a consistent metallicity scale between dwarfs and giants. The preferred method should constrain the three parameters $T_{ m eff}$, $\log~g$, and $ξ$ independent of spectroscopy. In particular, the lines should be chosen to be free of blends in the spectra of giants. When attention is paid to the line list, the classical spectroscopic method can also produce consistent results. The metallicities derived with the well-constrained set of stellar parameters are consistent independent of the line list used. Therefore, for this cluster we favor the metallicity of +0.18$\pm$0.03 dex obtained with this method. The classical spectroscopic analysis, using the line list optimized for the giants, provides a metallicity of +0.14$\pm$0.03 dex, in agreement with previous works.

Motivation & Objective

  • To resolve inconsistencies in metallicity scales between cool dwarfs and giants that may arise from systematic errors in stellar parameter determination.
  • To test whether spectroscopic abundance analyses of dwarfs and giants can yield consistent results when using a unified methodology.
  • To evaluate the impact of line list selection, continuum placement, and instrumental differences on metallicity precision.
  • To determine the most robust method for deriving consistent metallicities across different stellar types in open clusters.
  • To provide a benchmark for future studies of stellar metallicity and planet formation by validating a consistent analysis framework.

Proposed method

  • Employed interferometric measurements of angular diameters for Hyades giants to constrain effective temperature ($T_{\rm eff}$) and surface gravity ($\log g$) independently of spectroscopy.
  • Developed a novel microturbulence ($\xi$) calibration based on 3D hydrodynamical model atmospheres, enabling $\xi$ estimation independent of spectroscopic line fitting.
  • Applied two analysis methods: Method M1 (non-spectroscopic parameter determination) and Method M2 (classical spectroscopic analysis using Fe I and Fe II lines).
  • Tested two line lists—MASH and ASPL—focusing on minimizing blending and non-LTE effects, especially in giant star spectra.
  • Used the infrared flux method (IRFM) for dwarfs to derive $T_{\rm eff}$, and theoretical evolutionary tracks to constrain $\log g$.
  • Performed differential abundance analysis using the Sun as a reference, but evaluated the limitations of this approach in canceling systematic effects.

Experimental results

Research questions

  • RQ1Can a consistent metallicity scale be achieved for cool dwarfs and giants when they are analyzed under the same physical assumptions?
  • RQ2To what extent do systematic errors in atmospheric parameter determination—especially $T_{\rm eff}$, $\log g$, and $\xi$—introduce spurious metallicity differences between dwarfs and giants?
  • RQ3How critical is the choice of spectral line list in achieving consistency between metallicity determinations for dwarfs and giants?
  • RQ4Does using a 3D model-based microturbulence calibration improve the robustness and consistency of metallicity measurements across stellar types?
  • RQ5What is the minimum achievable precision in differential abundance analysis when systematic effects like continuum placement and instrument differences are not fully canceled?

Key findings

  • A consistent metallicity scale for cool dwarfs and giants is achievable when atmospheric parameters are constrained independently of spectroscopy, particularly using interferometric data and 3D model-based microturbulence calibration.
  • The preferred method (M1) yields a metallicity of 0.18 ± 0.03 dex for the Hyades cluster, which is robust across different line lists and shows no significant systematic offset between dwarfs and giants.
  • Classical spectroscopic analysis (M2) with a line list optimized for giants (ASPL) yields a metallicity of 0.14 ± 0.03 dex, in agreement with previous studies and consistent with M1 within uncertainties.
  • Using a line list not optimized for giants (e.g., MASH) introduces systematic differences of up to 0.06 dex between dwarfs and giants, highlighting the necessity of tailored line lists.
  • Systematic errors from continuum placement and instrument differences can introduce shifts of ~0.03 dex and 0.05 dex, respectively, limiting the precision of non-line-by-line differential analyses to ~0.03 dex.
  • The M1 method shows superior robustness, as it produces consistent results regardless of line list, indicating that well-constrained parameters can compensate for line list imperfections.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.