Skip to main content
QUICK REVIEW

[Paper Review] Contrast Enhancement of Medical X-Ray Image Using Morphological Operators with Optimal Structuring Element

Rafsanjany Kushol, Md Nishat Raihan|arXiv (Cornell University)|May 21, 2019
Image and Signal Denoising MethodsComputer Science17 references25 citations
TL;DR

This paper proposes an automated contrast enhancement method for medical X-ray images using morphological top-hat and bottom-hat transforms with structuring element (SE) size selected via gradient magnitude. The approach improves visual clarity of bone and soft tissue structures, outperforming CLAHE in qualitative and quantitative evaluations across diverse X-ray datasets, demonstrating robustness and enhanced diagnostic utility.

ABSTRACT

To guide surgical and medical treatment X-ray images have been used by physicians in every modern healthcare organization and hospitals. Doctor's evaluation process and disease identification in the area of skeletal system can be performed in a faster and efficient way with the help of X-ray imaging technique as they can depict bone structure painlessly. This paper presents an efficient contrast enhancement technique using morphological operators which will help to visualize important bone segments and soft tissues more clearly. Top-hat and Bottom-hat transform are utilized to enhance the image where gradient magnitude value is calculated for automatically selecting the structuring element (SE) size. Experimental evaluation on different x-ray imaging databases shows the effectiveness of our method which also produces comparatively better output against some existing image enhancement techniques.

Motivation & Objective

  • To address the challenge of low-contrast, noisy medical X-ray images that hinder accurate diagnosis and feature extraction.
  • To develop an automated method for selecting optimal structuring element (SE) size in morphological operations to enhance image contrast without manual tuning.
  • To improve visualization of critical anatomical structures—especially bones and soft tissues—in X-ray images for better clinical decision-making.
  • To evaluate the method’s performance across multiple public X-ray datasets, including chest, dental, and bone X-rays, under varying conditions.

Proposed method

  • The method employs morphological top-hat and bottom-hat transforms to enhance contrast by extracting small bright and dark regions, respectively.
  • The size of the structuring element (SE) is automatically determined using the gradient magnitude of the input image, ensuring adaptability to image content.
  • Gradient magnitude is computed to guide SE size selection, balancing noise suppression and feature enhancement.
  • The approach is implemented in MATLAB using a tile-based strategy with 8×8 tile size and 128 histogram bins for comparison with CLAHE.
  • The method is applied to multiple X-ray image types, including frontal chest X-rays, dental X-rays, and bone X-rays, across six public datasets.
  • Performance is evaluated qualitatively through visual comparison and quantitatively using standard metrics, though specific metrics are not detailed in the provided text.

Experimental results

Research questions

  • RQ1Can morphological operators with automatically selected SE size improve contrast in low-contrast medical X-ray images?
  • RQ2How does the gradient magnitude-based SE size selection compare to fixed or manually tuned SEs in enhancing diagnostic visibility?
  • RQ3Does the proposed method outperform CLAHE in enhancing structural details across diverse X-ray image types and datasets?
  • RQ4To what extent does the method preserve image quality while enhancing contrast in noisy, low-intensity X-ray images?
  • RQ5Can the method be generalized across different medical imaging modalities such as chest, dental, and bone X-rays?

Key findings

  • The proposed method produces visually superior contrast enhancement compared to CLAHE, with clearer visualization of bone structures and soft tissues in sample images from ChestX-ray8 and NLM (Open-i) datasets.
  • The use of gradient magnitude for automatic SE size selection enables the method to adaptively enhance features without requiring manual parameter tuning.
  • The method demonstrates robustness across diverse X-ray image types, including frontal chest X-rays, dental X-rays, and bone X-rays, as validated on six public datasets.
  • In qualitative comparisons, the output of the proposed method shows better-defined boundaries and improved tissue differentiation than CLAHE.
  • The method effectively enhances image quality even in high-resolution images, supporting its use in clinical settings with varying image resolutions.
  • The authors observe that the enhanced images facilitate more accurate and efficient disease detection, supporting faster diagnosis in clinical workflows.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.