[Paper Review] Cross-Vendor CT Image Data Harmonization Using CVH-CT

Md. Selim, Jie Zhang|PubMed|Oct 19, 2021
Radiomics and Machine Learning in Medical ImagingMedicine30 references5 citations
TL;DR

This paper proposes CVH-CT, a novel deep learning framework for cross-vendor CT image harmonization that uses unpaired training data to reduce scanner-induced variability in radiomic features. By integrating a self-attention mechanism (CBAM) and a VGG-based domain loss to capture scanner-specific texture distributions, CVH-CT significantly outperforms existing methods in preserving anatomical detail and improving feature reproducibility across vendors.

ABSTRACT

While remarkable advances have been made in Computed Tomography (CT), most of the existing efforts focus on imaging enhancement while reducing radiation dose. How to harmonize CT image data captured using different scanners is vital in cross-center large-scale radiomics studies but remains the boundary to explore. Furthermore, the lack of paired training image problem makes it computationally challenging to adopt existing deep learning models. We propose a novel deep learning approach called CVH-CT for harmonizing CT images captured using scanners from different vendors. The generator of CVH-CT uses a self-attention mechanism to learn the scanner-related information. We also propose a VGG feature based domain loss to effectively extract texture properties from unpaired image data to learn the scanner based texture distributions. The experimental results show that CVH-CT is clearly better than the baselines because of the use of the proposed domain loss, and CVH-CT can effectively reduce the scanner-related variability in terms of radiomic features.

Motivation & Objective

  • To address the challenge of radiomic feature discrepancies caused by different CT scanner vendors in multi-center studies.
  • To enable CT image harmonization without requiring paired training data, which is often unavailable in clinical settings.
  • To develop a deep learning model that effectively learns and transfers scanner-specific texture distributions across vendors.
  • To improve the reproducibility of radiomic features across different CT scanners by synthesizing images that match the target scanner's distribution.
  • To validate the method on both cross-vendor and cross-protocol CT image harmonization tasks.

Proposed method

  • CVH-CT employs a CycleGAN-like framework with two generators (A2B and B2A) to translate images between two CT scanner domains (e.g., GE to Siemens, Siemens to GE).
  • The generator network incorporates CBAM (Convolutional Block Attention Module) to enhance global feature learning, particularly scanner-specific texture patterns.
  • A novel VGG-based domain loss is introduced to compute feature-level differences between synthesized and target images, enabling effective distribution matching without paired data.
  • The model uses a combination of adversarial loss, cycle-consistency loss, and the proposed domain loss to train the generators and discriminators end-to-end.
  • The domain loss computes feature gaps in deep feature spaces (via VGG-16) to guide the network in learning the target domain’s texture characteristics.
  • The framework is trained on unpaired CT images from different vendors or reconstruction protocols, enabling zero-shot harmonization.

Experimental results

Research questions

  • RQ1Can a deep learning model effectively harmonize CT images across different vendors without requiring paired training data?
  • RQ2How well can a self-attention mechanism like CBAM capture scanner-specific texture distributions in CT images?
  • RQ3To what extent does a VGG-based domain loss improve feature consistency in unpaired image translation for CT harmonization?
  • RQ4Does the proposed method preserve anatomical structures while reducing scanner-induced radiomic variability?
  • RQ5Can the model generalize to cross-protocol harmonization (e.g., different reconstruction kernels on the same scanner)?

Key findings

  • CVH-CT achieved the highest concordance correlation coefficient (CCC) scores in five out of six radiomic feature classes during GE-to-Siemens and Siemens-to-GE conversions, significantly outperforming CycleGAN and other baselines.
  • The CCC scores for first-order features were close to 1.0 across all models, indicating strong preservation of anatomical details.
  • For texture-based features, CVH-CT showed a substantial improvement over CycleGAN, with CCC scores exceeding 0.85 in most classes.
  • The PSNR, SSIM, and NCC metrics confirmed that CVH-CT produced synthesized images with higher visual quality and structural similarity to target images.
  • In cross-protocol harmonization (e.g., Bl64 to Br40 kernel), CVH-CT achieved CCC scores of 0.87 ± 0.12 and 0.86 ± 0.10, demonstrating robustness beyond vendor differences.
  • Visual analysis of residual maps showed that CVH-CT had the lowest dissimilarity to target images, with most values near 0 (blue), indicating high fidelity in synthesis.