Skip to main content
QUICK REVIEW

[Paper Review] CT-Flow: Orchestrating CT Interpretation Workflow with Model Context Protocol Servers

Yannian Gu, Xizhuo Zhang|arXiv (Cornell University)|Feb 23, 2026
Multimodal Machine Learning ApplicationsComputer Science0 citations
TL;DR

CT-Flow introduces an agentic framework that uses Model Context Protocol (MCP) servers to orchestrate 3D CT interpretation via tool use, turning passive perception into iterative, tool-mediated reasoning. It yields state-of-the-art results on 3D CT benchmarks and a new CT-FlowBench trajectory-based benchmark.

ABSTRACT

Recent advances in Large Vision-Language Models (LVLMs) have shown strong potential for multi-modal radiological reasoning, particularly in tasks like diagnostic visual question answering (VQA) and radiology report generation. However, most existing approaches for 3D CT analysis largely rely on static, single-pass inference. In practice, clinical interpretation is a dynamic, tool-mediated workflow where radiologists iteratively review slices and use measurement, radiomics, and segmentation tools to refine findings. To bridge this gap, we propose CT-Flow, an agentic framework designed for interoperable volumetric interpretation. By leveraging the Model Context Protocol (MCP), CT-Flow shifts from closed-box inference to an open, tool-aware paradigm. We curate CT-FlowBench, the first large-scale instruction-tuning benchmark tailored for 3D CT tool-use and multi-step reasoning. Built upon this, CT-Flow functions as a clinical orchestrator capable of decomposing complex natural language queries into automated tool-use sequences. Experimental evaluations on CT-FlowBench and standard 3D VQA datasets demonstrate that CT-Flow achieves state-of-the-art performance, surpassing baseline models by 41% in diagnostic accuracy and achieving a 95% success rate in autonomous tool invocation. This work provides a scalable foundation for integrating autonomous, agentic intelligence into real-world clinical radiology.

Motivation & Objective

  • Motivate radiology AI to reflect real-world, tool-mediated CT interpretation workflows.
  • Shift 3D CT analysis from passive encoding to active, agentic probing via MCP.
  • Provide a standardized benchmark (CT-FlowBench) to evaluate tool-use trajectories in CT tasks.
  • Demonstrate that agentic, tool-mediated reasoning improves diagnostic accuracy and transparency.

Proposed method

  • Define a standardized tool space via MCP with four tool suites: Data Ingestion, Global Navigation, Detailed Observation, Advanced Analysis.
  • Formulate diagnostic tasks as iterative Reasoning-Acting Trajectories (s_t, a_t, o_t) following a ReAct-inspired loop.
  • Construct CT-FlowBench from CT-RATE data to capture executable reasoning trajectories with ground-truth diagnoses.
  • Train and evaluate agents using supervised fine-tuning (SFT) on CT-FlowBench and standard 3D CT VQA datasets.
  • Benchmark against leading frontier LLMs and specialized medical VLMs to assess tool-use benefits and generalization.
Figure 1: Comparison of 3D CT analysis paradigms. Left: Traditional End-to-End LVLMs rely on passive visual ingestion of 3D data, resulting in static textual outputs. Right: The proposed CT-Flow framework leverages the Model Context Protocol to transform the LLM into an active agent. It dynamically
Figure 1: Comparison of 3D CT analysis paradigms. Left: Traditional End-to-End LVLMs rely on passive visual ingestion of 3D data, resulting in static textual outputs. Right: The proposed CT-Flow framework leverages the Model Context Protocol to transform the LLM into an active agent. It dynamically

Experimental results

Research questions

  • RQ1Can an agentic CT interpretation framework achieve higher diagnostic accuracy than static, slice-based or end-to-end LVLM approaches?
  • RQ2Does MCP-supported tool use enable reliable, multi-step reasoning and autonomous tool invocation in 3D CT tasks?
  • RQ3What is the impact of domain-specific fine-tuning (SFT) on tool-mediated CT reasoning performance?
  • RQ4How does CT-Flow's tool orchestration compare to baselines in standard 3D CT VQA benchmarks and CT-FlowBench trajectories?

Key findings

  • CT-Flow-8B achieves state-of-the-art 3D-RAD accuracy at 69.46%.
  • CT-Flow improves diagnostic accuracy by +22.46% over slice-based baselines on 3D-RAD.
  • On CT-FlowBench, high-capacity models show gains from tool-mediated reasoning, with GPT-5.2 and Gemini-3-Pro-Preview outperforming some medical models in aggregate metrics.
  • CT-Flow (SFT) demonstrates strong tool-use autonomy, achieving up to 95% success in autonomous tool invocation.
  • CT-FlowBench presents multi-step, executable reasoning trajectories; final accuracy reflects complex, multi-stage diagnosis rather than single-slice judgments.
  • Ablation shows all four tool categories (Data Ingestion, Global Navigation, Detailed Observation, Advanced Analysis) are essential for performance.
Figure 2: Overview of the CT-Flow framework. (i) Data Construction: The pipeline for raw data curation, trajectory synthesis, and the establishment of the CT-Flow benchmark. (ii) Architectures: The system decouples the LLM orchestrator from the imaging environment via FASTMCP, bridging high-level se
Figure 2: Overview of the CT-Flow framework. (i) Data Construction: The pipeline for raw data curation, trajectory synthesis, and the establishment of the CT-Flow benchmark. (ii) Architectures: The system decouples the LLM orchestrator from the imaging environment via FASTMCP, bridging high-level se

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.