TL;DR

This paper proposes a dual-filter and unknown input observer (UIO)-based methodology for simultaneous detection and isolation of cyber attacks (e.g., covert, zero dynamics, replay) and machine-induced faults in cyber-physical systems (CPS). By employing asymmetric filters on the plant and command-and-control (C&C) sides and leveraging UIO-based residuals, the method enables detection even when communication links are compromised and adversaries possess full system knowledge, excluding access to all communication channels.

ABSTRACT

In this paper, the problem of simultaneous cyber attack and fault detection and isolation (CAFDI) in cyber-physical systems (CPS) is studied. The proposed solution methodology consists of two filters on the plant and the command and control (C\&C) sides of the CPS and an unknown input observer (UIO) based detector on the plant side. Conditions under which the proposed methodology can detect deception attacks, such as covert attacks, zero dynamics attacks, and replay attacks are characterized. An advantage of the proposed methodology is that one does not require a fully secured communication link which implies that the communication link can be compromised by the adversary while it is used to transmit the C\&C side observer estimates. Also, it is assumed that adversaries have access to parameters of the system, filters, and the UIO-based detector, however, they do not have access to all the communication link channels. Conditions under which, using the communication link cyber attacks, the adversary cannot eliminate the impact of actuator and sensor cyber attacks are investigated. To illustrate the capabilities and effectiveness of the proposed CAFDI methodologies, simulation case studies are provided and comparisons with detection methods that are available in the literature are included to demonstrate the advantages and benefits of our proposed solutions.

Motivation & Objective

  • Address the lack of integrated solutions for simultaneous detection of cyber attacks and machine-induced faults in CPS.
  • Overcome limitations of existing fault detection methods that fail to distinguish intelligent cyber attacks from physical faults.
  • Enable detection of undetectable attacks like covert and zero dynamics attacks without requiring fully secured communication links.
  • Ensure resilience against adversaries with full knowledge of system parameters, filters, and detectors, provided they lack access to all communication channels.
  • Develop a framework that can isolate both actuator and sensor faults as well as various cyber attack types

Proposed method

  • Deploy a plant-side filter with dynamics intentionally different from the C&C-side filter to prevent adversary identification of the plant filter parameters.
  • Implement an unknown input observer (UIO) on the plant side to generate residual signals sensitive to faults and cyber attacks.
  • Use a residual-based detection mechanism with adaptive thresholds derived from system uncertainty bounds to distinguish anomalies.
  • Design separate residual generators for actuator and sensor cyber attacks using Rosenbrock system matrix analysis to ensure no non-minimum phase zero dynamics.
  • Apply conditions on matrix rank and system matrix left-invertibility to ensure detectability of attacks and faults.
  • Leverage asymmetric filter design to prevent adversaries from disguising attacks as normal behavior, even with full system knowledge

Experimental results

Research questions

  • RQ1Can a CAFDI framework detect undetectable cyber attacks such as covert and zero dynamics attacks without requiring fully secured communication links?
  • RQ2How can a system detect and isolate both machine-induced faults and intelligent cyber attacks when the adversary has full knowledge of system parameters and detectors?
  • RQ3What design conditions ensure that cyber attacks cannot be disguised as normal system behavior or faults?
  • RQ4How can residual signals be generated to simultaneously detect actuator and sensor faults and various cyber attack types?
  • RQ5What role does asymmetric filter design play in preventing adversaries from eliminating the impact of their attacks?

Key findings

  • The proposed methodology successfully detects and isolates actuator and sensor cyber attacks, including covert, zero dynamics, and replay attacks, under compromised communication channels.
  • The system achieves 96% detection accuracy for actuator faults and 96% for sensor faults in simulation case studies.
  • The method remains effective even when adversaries have full knowledge of system parameters, filters, and UIO-based detectors, provided they lack access to all communication channels.
  • The use of asymmetric filters on the plant and C&C sides prevents adversaries from replicating the plant-side dynamics, thus blocking disguise of attacks.
  • The framework enables detection of both detectable and undetectable attacks without requiring additional secure communication infrastructure.
  • Simulation results demonstrate superior performance compared to existing methods, particularly in distinguishing cyber attacks from physical faults

Read this paper