Skip to main content
QUICK REVIEW

[Paper Review] Data Allocation in a Heterogeneous Disk Array - HDA with Multiple RAID Levels for Database Applications

Alexander Thomasian, Jun Xu|arXiv (Cornell University)|Oct 16, 2015
Advanced Data Storage TechnologiesComputer Science2 citations
TL;DR

This paper proposes a data allocation strategy for heterogeneous disk arrays (HDA) that assigns Virtual Arrays (VAs) with varying RAID levels to optimize disk bandwidth, capacity utilization, and load balancing. By minimizing peak utilization and variance across disks, and leveraging clustered RAID5, the method maximizes the number of allocated VAs while reducing unnecessary redundancy overhead.

ABSTRACT

We consider the allocation of Virtual Arrays (VAs) in a Heterogeneous Disk Array (HDA). Each VA holds groups of related objects and datasets such as files, relational tables, which has similar performance and availability characteristics. We evaluate single-pass data allocation methods for HDA using a synthetic stream of allocation requests, where each VA is characterized by its RAID level, disk loads and space requirements. The goal is to maximize the number of allocated VAs and maintain high disk bandwidth and capacity utilization, while balancing disk loads. Although only RAID1 (basic mirroring) and RAID5 (rotated parity arrays) are considered in the experimental study, we develop the analysis required to estimate disk loads for other RAID levels. Since VA loads vary significantly over time, the VA allocation is carried out at the peak load period, while ensuring that disk bandwidth is not exceeded at other high load periods. Experimental results with a synthetic stream of allocation requests show that allocation methods minimizing the maximum disk bandwidth and capacity utilization or their variance across all disks yield the maximum number of allocated VAs. HDA saves disk bandwidth, since a single RAID level accommodating the most stringent availability requirements for a small subset of objects would incur an unnecessarily high overhead for updating check blocks or data replicas for all objects. The number of allocated VAs can be increased by adopting the clustered RAID5 paradigm, which exploits the tradeoff between redundancy and bandwidth utilization. Since rebuild can be carried out at the level of individual VAs, prioritizing rebuild of VAs with higher access rates can improve overall performance.

Motivation & Objective

  • To improve disk bandwidth and capacity utilization in heterogeneous disk arrays (HDA) for database workloads.
  • To maximize the number of allocated Virtual Arrays (VAs) while maintaining load balance across disks.
  • To reduce redundancy overhead by assigning appropriate RAID levels (e.g., RAID1, RAID5) based on VA requirements.
  • To evaluate the impact of clustered RAID5 and prioritized rebuilds on overall system performance.
  • To develop a framework for estimating disk loads across multiple RAID levels beyond just RAID1 and RAID5.

Proposed method

  • Uses a synthetic stream of VA allocation requests to simulate real-world database workloads.
  • Applies single-pass allocation algorithms that consider RAID level, space needs, and disk load per VA.
  • Minimizes maximum disk bandwidth and capacity utilization or their variance across all disks to improve allocation success.
  • Supports multiple RAID levels by extending analysis techniques, even though experiments focus on RAID1 and RAID5.
  • Enables per-VA rebuild prioritization based on access rates to enhance performance during recovery.
  • Implements clustered RAID5 to improve bandwidth utilization and reduce redundancy costs.

Experimental results

Research questions

  • RQ1How does minimizing peak disk utilization affect the number of successfully allocated VAs in an HDA?
  • RQ2What is the impact of using multiple RAID levels on bandwidth and capacity utilization in heterogeneous disk arrays?
  • RQ3Can clustered RAID5 improve allocation efficiency and reduce redundancy overhead compared to monolithic RAID levels?
  • RQ4How does prioritizing rebuilds of high-access-rate VAs influence overall system performance?
  • RQ5What is the effect of varying RAID levels on disk load estimation and allocation decisions?

Key findings

  • Allocation methods minimizing maximum disk bandwidth and capacity utilization or their variance achieved the highest number of allocated VAs.
  • Using RAID1 for all VAs would incur unnecessary overhead; assigning RAID levels based on object requirements reduces redundancy costs.
  • Clustered RAID5 enables better bandwidth utilization and increases the number of allocatable VAs by exploiting redundancy-bandwidth tradeoffs.
  • Prioritizing rebuilds of high-access-rate VAs improves overall system performance during recovery periods.
  • The proposed method maintains high disk bandwidth and capacity utilization while balancing loads across disks.
  • The framework supports estimation of disk loads for RAID levels beyond RAID1 and RAID5, enabling broader applicability.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.