Skip to main content
QUICK REVIEW

[Paper Review] DaTscan SPECT Image Classification for Parkinson's Disease

Justin Quan, Xu Lin|arXiv (Cornell University)|Sep 9, 2019
Brain Tumor Detection and ClassificationNeuroscience14 references10 citations
TL;DR

This study proposes a deep convolutional neural network (CNN) using the InceptionV3 architecture to classify DaTscan SPECT images as Parkinson’s Disease (PD) or normal, leveraging a 3-slice (40–42) RGB concatenation and data augmentation to handle small datasets. The model achieved 98.48% test accuracy, 99.67% PR AUC, and 99.09% ROC AUC, demonstrating high sensitivity (98.88%) and specificity (97.67%) on a 659-image PPMI dataset.

ABSTRACT

Parkinson's Disease (PD) is a neurodegenerative disease that currently does not have a cure. In order to facilitate disease management and reduce the speed of symptom progression, early diagnosis is essential. The current clinical, diagnostic approach is to have radiologists perform human visual analysis of the degeneration of dopaminergic neurons in the substantia nigra region of the brain. Clinically, dopamine levels are monitored through observing dopamine transporter (DaT) activity. One method of DaT activity analysis is performed with the injection of an Iodine-123 fluoropropyl (123I-FP-CIT) tracer combined with single photon emission computerized tomography (SPECT) imaging. The tracer illustrates the region of interest in the resulting DaTscan SPECT images. Human visual analysis is slow and vulnerable to subjectivity between radiologists, so the goal was to develop an introductory implementation of a deep convolutional neural network that can objectively and accurately classify DaTscan SPECT images as Parkinson's Disease or normal. This study illustrates the approach of using a deep convolutional neural network and evaluates its performance on DaTscan SPECT image classification. The data used in this study was obtained through a database provided by the Parkinson's Progression Markers Initiative (PPMI). The deep neural network in this study utilizes the InceptionV3 architecture, 1st runner up in the 2015 ImageNet Large Scale Visual Recognition Competition (ILSVRC), as a base model. A custom, binary classifier block was added on top of this base. In order to account for the small dataset size, a ten fold cross validation was implemented to evaluate the model's performance.

Motivation & Objective

  • To develop an objective, automated method for classifying DaTscan SPECT images as PD or non-PD to reduce reliance on subjective radiologist readings.
  • To evaluate the performance of a deep CNN on a small, imbalanced dataset of DaTscan SPECT images from the PPMI database.
  • To explore data augmentation and transfer learning techniques to improve model generalization despite limited training data.
  • To assess the feasibility of using 3D SPECT image slices as 2D RGB inputs for effective deep learning-based classification.

Proposed method

  • The study employed transfer learning using the pre-trained InceptionV3 architecture as a feature extractor, fine-tuned on DaTscan SPECT images.
  • Slices 40, 41, and 42—selected for highest intensity in the striatal region—were concatenated into a 3-channel RGB image to preserve spatial context.
  • Data augmentation was applied on-the-fly using Keras' ImageDataGenerator with small rotations, shifts, and flips to increase effective dataset size.
  • A 10-fold cross-validation was used to evaluate model robustness, followed by a final 80:20 train-test split with class-balanced sampling.
  • The model was trained for 500 epochs with a cosine decay learning rate schedule from 1e-3 to 1e-6 and batch size of 16.
  • Performance was evaluated using standard metrics: accuracy, AUC-ROC, AUC-PR, sensitivity, specificity, and precision.

Experimental results

Research questions

  • RQ1Can a deep CNN effectively classify DaTscan SPECT images into PD and non-PD categories with high accuracy?
  • RQ2How does data augmentation and transfer learning improve performance on a small, imbalanced medical imaging dataset?
  • RQ3To what extent does selecting specific SPECT slices (40–42) affect classification performance compared to using full volumetric data?
  • RQ4How do the model’s sensitivity and specificity compare to clinical diagnostic standards?

Key findings

  • The model achieved a test accuracy of 98.48% on 132 unseen test images, with 88 true positives and 42 true negatives.
  • Sensitivity reached 98.88%, indicating the model correctly identified 98.88% of PD cases.
  • Specificity was 97.67%, showing the model correctly classified 97.67% of non-PD cases.
  • Precision was 98.88%, meaning 98.88% of predicted PD cases were correct.
  • The area under the PR curve was 0.9967, indicating excellent precision-recall performance.
  • The area under the ROC curve was 0.9909, demonstrating strong discriminative ability between PD and non-PD classes.