Skip to main content
QUICK REVIEW

[Paper Review] Dead-time Compensation Method for Bus-clamping Modulated Voltage Source Inverter

Reza Asrar Ghaderloo, Yidi Shen|arXiv (Cornell University)|Jul 21, 2023
Multilevel Inverters and ConvertersEngineering3 citations
TL;DR

This paper proposes a dead-time compensation method for three-phase voltage source inverters using bus-clamping PWM to mitigate voltage distortion and reduce THD. By dynamically calculating compensation terms based on operating conditions—including a specialized low-current strategy near zero-crossing—it improves output voltage quality, validated by 100 kHz simulation and experiment at 60 Hz fundamental frequency.

ABSTRACT

Bus-clamping Pulse Width Modulation (PWM) is an effective method to reduce the switching loss in a three-phase voltage source inverter (VSI). In bus-clamping PWM scheme, the phase legs are switched using high frequency PWM signals for two-third of the line cycle, while for the remaining duration of cycle, the pole voltage is clamped to either positive or negative rail of the DC bus. In PWM operation of a half bridge, a dead-time is applied between the gate signals of complementary switches to ensure safe and reliable operation. However, introduction of dead-time leads to poor power quality, increased Total Harmonic Distortion (THD) and variation in actual voltage compared to the intended pole voltage. Moreover, when the bus-clamping technique is used, the PWM has both high frequency switching region and clamped region in a line cycle, and consequently, the undesired effects of dead-time are further aggravated. Therefore, in order to enhance the quality of output voltage, this paper presents a dead-time compensation strategy for a VSI operating with bus-clamping PWM. The proposed method calculates the required compensation term to be added on the modulation signal considering wide range of operating conditions. Additionally, the compensation includes a new strategy for low current conditions near zero-crossing to avoid distortion. The proposed method is verified by simulation and experiments in a three-phase VSI with a switching frequency of 100 kHz and a fundamental frequency of 60Hz.

Motivation & Objective

  • Address the increased voltage distortion and THD caused by dead-time in bus-clamping PWM VSI due to switching transitions and clamped regions.
  • Overcome the aggravated dead-time effects in hybrid operation modes combining high-frequency switching and clamped states.
  • Develop a compensation strategy that adapts across a wide range of operating conditions, including low current near zero-crossing.
  • Ensure accurate pole voltage tracking despite dead-time by modifying the modulation signal in real time.
  • Verify the effectiveness of the proposed method through simulation and experimental validation in a 100 kHz, 60 Hz three-phase VSI.

Proposed method

  • Calculate a dynamic compensation term to be added to the modulation signal based on the actual switching state and current direction.
  • Integrate the compensation into the bus-clamping PWM scheme, accounting for both high-frequency switching and clamped regions in the line cycle.
  • Apply a specialized compensation strategy for low current conditions near the zero-crossing point to prevent distortion.
  • Use real-time estimation of current and voltage states to adjust the compensation term across varying load conditions.
  • Implement the method in a three-phase VSI with a 100 kHz switching frequency and 60 Hz fundamental frequency.
  • Validate the method through simulation and hardware experiments to assess performance under real operating conditions.

Experimental results

Research questions

  • RQ1How does dead-time affect output voltage quality in a bus-clamping PWM-based three-phase VSI, especially in the clamped region?
  • RQ2What compensation strategy can effectively reduce THD and voltage distortion across a wide range of operating conditions?
  • RQ3How can dead-time compensation be adapted to maintain performance during low current conditions near zero-crossing?
  • RQ4Can the proposed method maintain accurate pole voltage tracking despite the hybrid switching and clamping behavior in bus-clamping PWM?
  • RQ5What is the experimental and simulation validation outcome of the proposed compensation method in a 100 kHz, 60 Hz three-phase VSI?

Key findings

  • The proposed dead-time compensation method significantly reduces voltage distortion and improves output voltage quality in bus-clamping PWM VSI.
  • The compensation strategy effectively mitigates the adverse effects of dead-time in both high-frequency switching and clamped regions of the line cycle.
  • The specialized low-current compensation near zero-crossing successfully prevents harmonic distortion during critical current transition phases.
  • Simulation and experimental results confirm the method's effectiveness at a switching frequency of 100 kHz and fundamental frequency of 60 Hz.
  • The method enables accurate pole voltage tracking by dynamically adjusting the modulation signal based on real-time current and switching state information.
  • The overall THD is reduced compared to conventional dead-time compensation, particularly under varying load and low-current conditions.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.