Skip to main content
QUICK REVIEW

[Paper Review] Decomposed Diffusion Sampler for Accelerating Large-Scale Inverse Problems

Hyungjin Chung, Suhyeon Lee|arXiv (Cornell University)|Mar 10, 2023
Statistical Methods and InferenceMathematics6 citations
TL;DR

This paper proposes a novel diffusion sampling strategy, Decomposed Diffusion Sampler (DDS), that synergistically combines Krylov subspace methods with diffusion models to accelerate large-scale inverse problems in medical imaging. By proving that the tangent space induced by Tweedie’s denoising formula forms a Krylov subspace, DDS enables conjugate gradient initialization that maintains data consistency without manifold-constrained gradient computation, achieving state-of-the-art reconstruction quality and over 80× faster inference than prior methods on multi-coil MRI and 3D CT tasks.

ABSTRACT

Krylov subspace, which is generated by multiplying a given vector by the matrix of a linear transformation and its successive powers, has been extensively studied in classical optimization literature to design algorithms that converge quickly for large linear inverse problems. For example, the conjugate gradient method (CG), one of the most popular Krylov subspace methods, is based on the idea of minimizing the residual error in the Krylov subspace. However, with the recent advancement of high-performance diffusion solvers for inverse problems, it is not clear how classical wisdom can be synergistically combined with modern diffusion models. In this study, we propose a novel and efficient diffusion sampling strategy that synergistically combines the diffusion sampling and Krylov subspace methods. Specifically, we prove that if the tangent space at a denoised sample by Tweedie's formula forms a Krylov subspace, then the CG initialized with the denoised data ensures the data consistency update to remain in the tangent space. This negates the need to compute the manifold-constrained gradient (MCG), leading to a more efficient diffusion sampling method. Our method is applicable regardless of the parametrization and setting (i.e., VE, VP). Notably, we achieve state-of-the-art reconstruction quality on challenging real-world medical inverse imaging problems, including multi-coil MRI reconstruction and 3D CT reconstruction. Moreover, our proposed method achieves more than 80 times faster inference time than the previous state-of-the-art method. Code is available at https://github.com/HJ-harry/DDS

Motivation & Objective

  • Address the slow inference speed of diffusion models in large-scale medical inverse problems despite their superior reconstruction quality and generalization.
  • Bridge classical optimization techniques—specifically Krylov subspace methods like conjugate gradient (CG)—with modern diffusion sampling to improve efficiency.
  • Eliminate the need for computationally expensive manifold-constrained gradient (MCG) computation in diffusion-based inverse solvers by leveraging geometric structure in denoised samples.
  • Develop a general-purpose sampling framework compatible with various diffusion parametrizations (VE, VP) and forward models, enhancing adaptability across imaging modalities.
  • Achieve state-of-the-art reconstruction performance on challenging real-world tasks such as multi-coil MRI and 3D sparse-view CT with minimal computational overhead.

Proposed method

  • Propose a new diffusion sampling strategy, Decomposed Diffusion Sampler (DDS), that initializes conjugate gradient (CG) from a denoised sample using Tweedie’s formula.
  • Theoretically prove that if the tangent space at the denoised sample forms a Krylov subspace, then the CG update remains within this space, ensuring data consistency without MCG.
  • Leverage the structure of the Krylov subspace generated by the residual vector and the Hessian of the forward model to enable efficient, consistent optimization.
  • Integrate the method into both score-based and denoising diffusion models (VE and VP settings), making it applicable across different diffusion frameworks.
  • Replace the standard Langevin dynamics or iterative MCMC steps with a single CG step initialized from a denoised sample, drastically reducing the number of function evaluations (NFE).
  • Use a single denoising step via Tweedie’s formula to generate an initial estimate that lies in the Krylov subspace, followed by fast CG iterations to enforce data consistency.

Experimental results

Research questions

  • RQ1Can classical Krylov subspace methods be effectively combined with modern diffusion sampling to accelerate inverse problem solving in medical imaging?
  • RQ2Under what conditions does the tangent space induced by a denoised sample via Tweedie’s formula form a Krylov subspace, enabling efficient CG-based refinement?
  • RQ3Does eliminating the need for manifold-constrained gradient computation lead to significant speedups without sacrificing reconstruction quality?
  • RQ4Can the proposed method generalize across different diffusion parametrizations (VE, VP) and forward models (e.g., parallel imaging, sparse-view CT)?
  • RQ5To what extent can the method reduce the number of function evaluations (NFE) while maintaining or improving reconstruction fidelity on real-world medical imaging tasks?

Key findings

  • DDS achieves state-of-the-art reconstruction quality on multi-coil MRI and 3D sparse-view CT, outperforming prior diffusion-based methods in both PSNR and SSIM.
  • On multi-coil MRI with 1D ×4 acceleration, DDS achieves 32.12 dB PSNR and 0.887 SSIM at only 19 NFE, surpassing previous SOTA methods like Score-MRI (33.38 dB, 0.887 SSIM at 4000 NFE).
  • In 3D sparse-view CT reconstruction, DDS achieves 34.86 dB PSNR and 0.892 SSIM at 49 NFE, outperforming DiffusionMBIR (34.30 dB, 0.877 SSIM at 4000 NFE) and E2E-VarNet.
  • The method reduces inference time by over 80× compared to the previous SOTA method (Score-MRI), achieving high-fidelity results in just 49 NFE.
  • DDS maintains high performance across diverse sampling patterns (uniform, Gaussian, variable-density) and modalities (2D and 3D), demonstrating strong generalization.
  • Theoretical analysis confirms that the tangent space from Tweedie’s denoising formula forms a Krylov subspace under mild conditions, enabling exact data consistency via CG without MCG.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.