TL;DR

This paper proposes a deep convolutional neural network (CNN) to detect noise in mobile-ECG signals using a novel, human-annotated dataset of 10,463 ECGs. The 16-layer VGG16-inspired CNN achieves an AUC of 0.977 on 10-second input segments, significantly improving noise localization and enhancing downstream arrhythmia detection by excluding noisy intervals.

ABSTRACT

Mobile electrocardiogram (ECG) recording technologies represent a promising tool to fight the ongoing epidemic of cardiovascular diseases, which are responsible for more deaths globally than any other cause. While the ability to monitor one's heart activity at any time in any place is a crucial advantage of such technologies, it is also the cause of a drawback: signal noise due to environmental factors can render the ECGs illegible. In this work, we develop convolutional neural networks (CNNs) to automatically label ECGs for noise, training them on a novel noise-annotated dataset. By reducing distraction from noisy intervals of signals, such networks have the potential to increase the accuracy of models for the detection of atrial fibrillation, long QT syndrome, and other cardiovascular conditions. Comparing several architectures, we find that a 16-layer CNN adapted from the VGG16 network which generates one prediction per second on a 10-second input performs exceptionally well on this task, with an AUC of 0.977.

Motivation & Objective

  • To develop an automated method for detecting noise in mobile-ECG recordings, which often suffer from artifacts due to patient movement, RF interference, or poor contact.
  • To create a novel, human-annotated dataset of ECGs labeled for noise based on relative signal quality rather than absolute thresholds.
  • To evaluate multiple CNN architectures for noise detection, focusing on input length and network depth to optimize performance.
  • To improve the accuracy of downstream ECG analysis models by excluding noisy intervals, thereby enhancing detection of subtle features like P-waves.
  • To explore the feasibility of using deep learning for noise detection in single-lead, ambulatory ECGs where traditional methods are limited.

Proposed method

  • A custom dataset of 10,463 mobile ECGs from AliveCor KardiaMobile devices was created, with noise annotations based on relative signal quality—labeling intervals as noisy only if significantly noisier than the rest of the signal.
  • Input signals were segmented into 1-second or 2.6-second intervals, with majority voting used to assign binary noise labels to each segment.
  • Multiple CNN architectures were trained, including a 4-layer, 6-layer, 16-layer, and residual network, with input lengths of 10 seconds (3000 samples) and 30 seconds (9000 samples).
  • The 16-layer model was adapted from VGG16, using 3x3 convolutions and max-pooling layers to extract hierarchical temporal features from ECG signals.
  • A softmax output layer produced a probability score for each 1-second segment indicating the likelihood of noise, with class probabilities visualized as color gradients.
  • Model performance was evaluated using the area under the ROC curve (AUC), with the 16-layer 10-second model achieving the highest AUC of 0.977.

Experimental results

Research questions

  • RQ1Can a deep CNN effectively detect noise in mobile-ECG signals with high accuracy, outperforming traditional statistical or rule-based methods?
  • RQ2Does increasing input length from 2.6 seconds to 10 seconds improve noise detection performance by enabling better contextual modeling?
  • RQ3Is a deeper CNN architecture, such as a 16-layer VGG16 variant, more effective than shallower models for identifying noisy ECG segments?
  • RQ4Can a relative noise labeling strategy—where noise is defined by comparison to the rest of the signal—improve the robustness and clinical relevance of noise detection?
  • RQ5Does the predicted noise probability correlate with actual noise severity, suggesting potential for graded noise assessment?

Key findings

  • The 16-layer CNN with a 10-second input length achieved the highest performance, with an AUC of 0.977, outperforming all other architectures tested.
  • The 10-second input length enabled better context awareness and finer-grained noise localization compared to the 2.6-second input, improving precision in identifying noisy intervals.
  • The 6-layer CNN with 30-second inputs performed poorly (AUC = 0.956), likely due to limited ability to apply striding and reduced temporal resolution.
  • The model's predicted noise probabilities correlated well with perceived noise levels, suggesting potential for future extension to multi-class or regression-based noise severity estimation.
  • The relative noise labeling strategy—where noise is defined by deviation from the rest of the signal—proved effective, as it avoided false positives in uniformly noisy ECGs and preserved clean features in mixed-quality signals.
  • The results indicate that deep learning can achieve near-human-level accuracy in ECG noise detection, significantly enhancing the reliability of automated arrhythmia detection systems.