[Paper Review] Deep One-Class Classification via Interpolated Gaussian Descriptor
This paper proposes Interpolated Gaussian Descriptor (IGD), a novel one-class classification model that improves normality description by training a Gaussian anomaly classifier on adversarially interpolated samples, enhancing robustness to small or contaminated training sets. IGD achieves state-of-the-art performance across diverse benchmarks, including MNIST, CIFAR10, MVTec AD, and medical datasets, with superior detection accuracy and stability under distributional shift.
One-class classification (OCC) aims to learn an effective data description to enclose all normal training samples and detect anomalies based on the deviation from the data description. Current state-of-the-art OCC models learn a compact normality description by hyper-sphere minimisation, but they often suffer from overfitting the training data, especially when the training set is small or contaminated with anomalous samples. To address this issue, we introduce the interpolated Gaussian descriptor (IGD) method, a novel OCC model that learns a one-class Gaussian anomaly classifier trained with adversarially interpolated training samples. The Gaussian anomaly classifier differentiates the training samples based on their distance to the Gaussian centre and the standard deviation of these distances, offering the model a discriminability w.r.t. the given samples during training. The adversarial interpolation is enforced to consistently learn a smooth Gaussian descriptor, even when the training data is small or contaminated with anomalous samples. This enables our model to learn the data description based on the representative normal samples rather than fringe or anomalous samples, resulting in significantly improved normality description. In extensive experiments on diverse popular benchmarks, including MNIST, Fashion MNIST, CIFAR10, MVTec AD and two medical datasets, IGD achieves better detection accuracy than current state-of-the-art models. IGD also shows better robustness in problems with small or contaminated training sets. Code is available at https://github.com/tianyu0207/IGD.
Motivation & Objective
- To address overfitting in state-of-the-art one-class classification (OCC) models when training data is small or contaminated with anomalies.
- To learn a more robust and representative normality description by focusing on central, normal samples rather than fringe or anomalous ones.
- To develop a theoretically grounded optimization framework that ensures smoothness and generalization of the normality descriptor.
- To evaluate the robustness of OCC models under realistic conditions such as data scarcity and contamination, which are common in industrial and medical applications.
Proposed method
- IGD introduces a one-class Gaussian anomaly classifier that scores samples based on their distance to the Gaussian center and the standard deviation of distances in the representation space.
- Adversarial interpolation is used to generate synthetic training samples between normal data points, enforcing smoothness in the learned normality descriptor.
- The model is optimized via an expectation-maximization (EM) algorithm derived from a probabilistic formulation, ensuring convergence to a stationary solution.
- Multi-scale structural and non-structural image reconstruction losses are incorporated to further regularize the representation space and improve generalization.
- The training process avoids collapsing to a single point by constraining the model to learn a meaningful, multi-dimensional normality description.
- The method is designed to be robust to data contamination and low-shot scenarios by emphasizing representative normal samples during interpolation and optimization.
Experimental results
Research questions
- RQ1Can adversarial interpolation improve the robustness of one-class classifiers in the presence of small or contaminated training sets?
- RQ2Does a Gaussian-based anomaly classifier with distance and variance modeling outperform hyper-sphere-based models like DSVDD in anomaly detection accuracy?
- RQ3To what extent does the EM-based optimization of the interpolated Gaussian descriptor improve generalization and prevent overfitting?
- RQ4How does IGD perform across diverse domains, including image classification, industrial defect detection, and medical imaging, under distributional shifts?
Key findings
- IGD achieves state-of-the-art mean testing AUC of 0.8252 on CIFAR10 with 1% anomalous contamination, outperforming DSVDD (0.7502) and DSVDD+REC (0.7694).
- On MVTec AD with 10% contamination, IGD achieves 0.9363 AUC, significantly outperforming DSVDD (0.8175) and DSVDD+REC (0.7687).
- With only 20% of the CIFAR10 training set, IGD maintains high performance (AUC ~0.81), while DSVDD and DSVDD+REC degrade sharply.
- IGD shows minimal performance fluctuation (max 1.3% on CIFAR10, 0.44% on MVTec) under contamination, compared to 7.8% and 3.5% for DSVDD.
- On medical datasets and Hyper-Kvasir (high-resolution), IGD achieves 93.7% AUC, outperforming CSI (91.6%) and matching or exceeding PANDA and DROC in key benchmarks.
- IGD demonstrates superior robustness in low-data and contaminated-data regimes, making it suitable for real-world industrial and clinical applications.
Read this paper
Open the full text in the Nubint reader and ask about any passage as you read.
Read this paper on NubintThis review was generated by AI from the original paper. Please check the paper before citing it.