TL;DR

This paper proposes a two-stage deep learning framework for 3D ultrasound catheter segmentation that combines deep Q-network (DQN)-driven coarse localization with a semi-supervised Dual-UNet for fine-grained segmentation. By leveraging hybrid constraints—uncertainty and contextual losses—on unlabeled data, the method achieves state-of-the-art performance with significantly fewer annotated images, reducing annotation burden while improving accuracy and efficiency over supervised and existing semi-supervised approaches.

ABSTRACT

Catheter segmentation in 3D ultrasound is important for computer-assisted cardiac intervention. However, a large amount of labeled images are required to train a successful deep convolutional neural network (CNN) to segment the catheter, which is expensive and time-consuming. In this paper, we propose a novel catheter segmentation approach, which requests fewer annotations than the supervised learning method, but nevertheless achieves better performance. Our scheme considers a deep Q learning as the pre-localization step, which avoids voxel-level annotation and which can efficiently localize the target catheter. With the detected catheter, patch-based Dual-UNet is applied to segment the catheter in 3D volumetric data. To train the Dual-UNet with limited labeled images and leverage information of unlabeled images, we propose a novel semi-supervised scheme, which exploits unlabeled images based on hybrid constraints from predictions. Experiments show the proposed scheme achieves a higher performance than state-of-the-art semi-supervised methods, while it demonstrates that our method is able to learn from large-scale unlabeled images.

Motivation & Objective

  • To reduce the high annotation cost of supervised deep learning in 3D ultrasound catheter segmentation.
  • To improve segmentation performance with limited labeled data by effectively utilizing abundant unlabeled 3D US images.
  • To develop a more efficient and accurate segmentation pipeline by integrating reinforcement learning for pre-localization.
  • To overcome limitations of existing semi-supervised learning methods, such as parameter correlation and unstable uncertainty estimation.
  • To enable real-time clinical deployment by reducing computational cost compared to exhaustive patch-based segmentation.

Proposed method

  • A deep Q-network (DQN) is trained to perform coarse catheter localization in 3D US by learning a policy to navigate through the volume, avoiding voxel-level annotations.
  • The DQN agent uses a $55^3$ observation space from a $128^3$ volume, with actions defined as discrete 3D movements to locate the catheter center.
  • A patch-based Dual-UNet is applied to segment the catheter around the DQN-detected region, using Compact-UNet as the backbone with dropout for uncertainty estimation.
  • The Dual-UNet is trained via a novel semi-supervised learning scheme combining supervised loss, intra- and inter-network uncertainty constraints, and a contextual constraint loss.
  • Uncertainty is estimated using Monte Carlo dropout with T=8 forward passes, and reliable predictions from unlabeled images are used as pseudo-labels.
  • A contextual constraint loss is introduced to enhance feature learning by enforcing consistency in semantic context across unlabeled patches.

Experimental results

Research questions

  • RQ1Can deep reinforcement learning reduce annotation effort in 3D ultrasound catheter segmentation without sacrificing localization accuracy?
  • RQ2How can unlabeled 3D US data be effectively leveraged to improve segmentation performance with limited labeled data?
  • RQ3Does a hybrid constraint-based semi-supervised learning scheme outperform existing uncertainty-aware and adversarial SSL methods in 3D catheter segmentation?
  • RQ4Can the integration of coarse localization and patch-based segmentation improve inference efficiency compared to full-volume or exhaustive patch methods?
  • RQ5What is the impact of uncertainty estimation and contextual modeling on the robustness and accuracy of semi-supervised 3D segmentation?

Key findings

  • The proposed method achieves a mean Dice Score of 4% higher than state-of-the-art semi-supervised methods on an ex-vivo 3D US dataset.
  • With only 18 labeled images and 42 unlabeled images, the method outperforms a supervised baseline using the same backbone network.
  • The DQN-based pre-localization achieves a localization accuracy of 4.3 ± 2.6 voxels (mean ± std.) in a $128^3$ volume, outperforming the $160^3$ case (4.7 ± 4.8 voxels).
  • The two-stage framework processes a 3D volume in approximately 1.2 seconds, significantly faster than the >10 seconds required by exhaustive patch-based methods.
  • Abllation studies confirm that each component of the hybrid constraint loss—uncertainty and contextual—contributes to improved performance, with the full model achieving the best results.
  • The $π$-model baseline underperforms compared to the proposed method due to unreliable pseudo-labels from unstable uncertainty estimation in complex 3D US images.