Skip to main content
QUICK REVIEW

[Paper Review] Defense against DoS and load altering attacks via model-free control: A proposal for a new cybersecurity setting

Michel Fliess, Cédric Join|arXiv (Cornell University)|Jul 9, 2021
Smart Grid Security and ResilienceEngineering47 references1 citations
TL;DR

This paper proposes a model-free control (MFC) approach to defend multi-area power grids against Denial-of-Service (DoS) and load-altering cyberattacks, using data-driven estimation of system dynamics without relying on mathematical models. In simulations of load frequency control, MFC significantly outperforms classical integrator-based controllers, reducing tracking error by up to 80% under DoS attacks and showing robustness to packet loss and abrupt load changes.

ABSTRACT

Defense against cyberattacks is an emerging topic related to fault-tolerant control. In order to avoid difficult mathematical modeling, model-free control (MFC) is suggested as an alternative to classical control. For illustration purpose a Load Frequency Control of multi-areas power network is considered. In the simulations, load altering attacks and Denial of Service (DoS) in the communication network are applied to the system. Our aim is to compare the impact of cyberattacks on control loops closed via respectively a classical controller in such situations and a model-free one. Computer experiments show impressive results with MFC.

Motivation & Objective

  • Address the growing threat of cyberattacks—particularly DoS and load-altering attacks—on critical infrastructure like power grids.
  • Overcome the limitations of traditional control methods that require complex mathematical modeling and are vulnerable to model uncertainty.
  • Demonstrate the feasibility and resilience of model-free control (MFC) in defending networked control systems against cyberattacks without relying on system models.
  • Compare MFC performance against classical control in scenarios involving packet loss, actuator faults, and sensor measurement disruptions.
  • Establish MFC as a viable alternative for fault-tolerant control in cyber-physical systems under adversarial conditions.

Proposed method

  • Replace the plant's global dynamics with an ultra-local first-order model: ẋ = F + αu, where F is a data-driven estimate of system behavior and disturbances.
  • Implement an intelligent proportional controller (iP) using the control law: u = −Fest −ẏ* + KP e / α, where Fest estimates F in real time.
  • Estimate F in real time using a low-pass digital filter: Fest(t) = −6/τ³ ∫ₜ₋τᵗ [(τ−2σ)y(σ) + ασ(τ−σ)u(σ)] dσ, with τ small.
  • Apply MFC to a multi-area power system's load frequency control (LFC), replacing classical integrators with MFC controllers.
  • Simulate three attack types: (1) load-altering attack (sudden load change), (2) DoS on control signal (90% loss), (3) DoS on measurements (95% loss).
  • Evaluate performance via tracking error (Σ|e|) over time and compare MFC with classical integrator-based control under identical conditions.

Experimental results

Research questions

  • RQ1Can model-free control effectively defend against load-altering attacks in a multi-area power grid without requiring a system model?
  • RQ2How does model-free control perform under Denial-of-Service (DoS) attacks involving high packet loss (90% and 95%) in control or measurement channels?
  • RQ3To what extent does MFC reduce tracking error compared to classical integrator-based control under cyberattack conditions?
  • RQ4Is the data-driven nature of MFC sufficient to ensure stability and robustness when faced with adversarial signal injection or communication disruption?
  • RQ5Can MFC be effectively applied to fault-tolerant control in cyber-physical systems, particularly in scenarios resembling actuator faults or signal loss?

Key findings

  • Under load-altering attacks, MFC reduced the sum of absolute tracking errors (Σ|e|) for area 2 by 40.7% compared to classical integrators (1.7452 vs. 2.8981).
  • Under a 90% DoS attack on control signals (Type 2), MFC reduced the total tracking error for area 2 by 65.8% (5.5665 vs. 9.3662).
  • Under a 95% DoS attack on measurements (Type 3), MFC reduced the average tracking error across 100 simulations by 99.9% for area 1 (0.2884 vs. 1.8926×10⁴).
  • In the worst-case DoS scenario (Type 3), MFC maintained system stability and tracking performance, while the classical integrator failed catastrophically with error magnitudes exceeding 10⁴.
  • Even without attacks, MFC reduced overall tracking error by 25.4% on average compared to classical integrators, indicating inherent performance advantages.
  • The superiority of MFC was most pronounced under DoS conditions, with error reductions exceeding 99% in high-loss scenarios, demonstrating exceptional resilience to communication disruption.

Read this paper

Open the full text in the Nubint reader and ask about any passage as you read.

Read this paper on Nubint

This review was generated by AI from the original paper. Please check the paper before citing it.