TL;DR

This paper proposes a deep learning approach using a multi-layer neural network to estimate the full 3D deformation of elastic objects—such as a human liver—from partial displacement observations of only ~3% of surface points. Trained on synthetic data generated via nonlinear finite element simulations, the method achieves an average estimation error of just 0.041 mm, demonstrating high accuracy even with minimal input data, making it promising for real-time surgical navigation systems.

ABSTRACT

Deformation estimation of elastic object assuming an internal organ is important for the computer navigation of surgery. The aim of this study is to estimate the deformation of an entire three-dimensional elastic object using displacement information of very few observation points. A learning approach with a neural network was introduced to estimate the entire deformation of an object. We applied our method to two elastic objects; a rectangular parallelepiped model, and a human liver model reconstructed from computed tomography data. The average estimation error for the human liver model was 0.041 mm when the object was deformed up to 66.4 mm, from only around 3 % observations. These results indicate that the deformation of an entire elastic object can be estimated with an acceptable level of error from limited observations by applying a trained neural network to a new deformation.

Motivation & Objective

  • To address the challenge of estimating full 3D organ deformation in laparoscopic surgery when only a few surface points can be tracked.
  • To overcome the limitation of partial observation in surgical navigation, where only a small fraction of the organ surface is visible.
  • To develop a machine learning method that infers complete deformation from sparse displacement data without requiring force measurements.
  • To evaluate the feasibility and accuracy of neural networks in estimating deformation of complex elastic structures like the human liver.
  • To enable real-time, accurate simulation of organ deformation during surgery using minimal observable data.

Proposed method

  • A multi-layer neural network is trained to map sparse displacement inputs from a small number of observable surface points to full displacement fields across all mesh vertices of the elastic object.
  • Deformation data for training is generated using a nonlinear finite element method (FEM) under known initial shapes and boundary conditions.
  • The input layer of the neural network has three times the number of nodes as the number of observation points (x, y, z coordinates), while the output layer predicts displacement for all non-fixed vertices.
  • The network is optimized via back-propagation with hyperparameters (hidden layer size, iteration count) selected through trial and error to balance accuracy and convergence speed.
  • The method assumes the initial geometry is known and focuses solely on predicting displacement from observed displacements, without requiring force or material property inputs.
  • The framework is validated on both a simple rectangular parallelepiped and a complex human liver model reconstructed from CT data.

Experimental results

Research questions

  • RQ1Can a neural network accurately estimate the full 3D deformation of an elastic object using only displacement data from a small number of observed surface points?
  • RQ2How does the estimation accuracy vary with the number and spatial distribution of observation points?
  • RQ3What is the optimal architecture (e.g., hidden layer size, training iterations) of the neural network for deformation estimation under partial observation?
  • RQ4How does mesh complexity (e.g., in the liver model vs. a simple box) affect estimation error?
  • RQ5Can the trained neural network generalize to new deformation scenarios or different organ geometries?

Key findings

  • The average estimation error for the human liver model was 0.041 mm when only around 3% of vertices were observed, indicating high accuracy under sparse observation.
  • For the liver model with multiple contact regions, the average error increased to 0.275 mm, still well below 1 mm and clinically acceptable.
  • The maximum error across all test cases was 2.06 mm, which is small relative to the mesh spacing of approximately 15 mm, indicating robustness to complex deformations.
  • The median error was 0.146 mm (0.33% of the 75th percentile error), showing consistent performance across diverse deformation patterns.
  • The method achieved reliable estimation even in regions not directly observed, suggesting strong generalization capability of the trained neural network.
  • The study demonstrates for the first time that neural networks can effectively learn to reconstruct full organ deformation from minimal displacement observations without force or material data.